main features
●This energy meter can measure real-time electrical parameters and energy of three-phase and four circuits, and one meter is equivalent to four three-phase electronic energy meters. Using LCD display, configuration parameters can be set with buttons; RS485 communication interface can be used to exchange data with the upper computer, supporting modbus RTU protocol and DLT645-2007 protocol, greatly facilitating power automation management.
●This electric energy meter has the advantages of small size, easy installation, high accuracy, and good EMC performance, which meets the relevant technical requirements of electronic electric energy meters in the national standard GB/T17215.
major function
This energy meter can measure real-time electrical parameters and energy of three-phase and six circuits, and one meter is equivalent to six three-phase electronic energy meters. Using LCD display, configuration parameters can be set with buttons; RS485 communication interface can be used to exchange data with the upper computer, supporting modbus RTU protocol and DLT645-2007 protocol, facilitating automation management of electricity consumption.
●Real time measurement of six channel total and phase separated electrical parameters
●Real time total energy and phase separated energy metering
●Demand recording and storage
●14 time periods with 4 different rates for energy metering and storage (not supported by Modbus protocol, supported by 645 protocol)
●Data storage and retrieval for 20 settlement days (Modbus protocol supports 20, 645 supports 12)
●60 timed freezing of data storage and reading (not supported by Modbus protocol, supported by 645 protocol)
●3 times of instantaneous freezing data storage and reading (not supported by Modbus protocol, supported by 645 protocol)
●Freeze data storage and reading for the next day (Modbus protocol supports 40 times, 645 supports 62 times)
●254 hourly freezing data storage and reading (not supported by Modbus protocol, supported by 645 protocol)
●3328 times storage and reading of load record data for categories 1-6 (not supported by Modbus protocol, supported by 645)
●Supports RS485 communication, verification methods, and baud rate settings
●Supports DLT645-2007 protocol and Modbus RTU protocol
●8-bit wide temperature LCD, displaying electrical parameters and energy
●Key setting configuration parameters and battery reset
●LED status indication
●After power failure, all stored data will not be lost and can be maintained for more than 10 years
●High precision real-time clock with backup battery, supporting perpetual calendar