Qingdao Dasen Environmental Protection Equipment Co., Ltd
Home>Products>Kane KM950 Handheld Smoke Analyzer
Kane KM950 Handheld Smoke Analyzer
Kane KM950 Handheld Smoke Analyzer
Product details

Kane KM950 Handheld Smoke Analyzerbrief introduction

Suitable for boiler combustion testing and pollution emission monitoring

Handheld, fully displayed in Chinese, easy to operate and convenient for on-site use

It can measure O2 SO2、NO、NO2、CO、 Flue gas temperature, ambient temperature, flue gas pressure, overall efficiency

Automatically calculate the flow rate of flue gas CO2、NOx、 Net efficiency, total loss, net loss, excess air coefficient

Built in dual head powerful vacuum pump ensures normal operation under high negative pressure and fast response time

Flexible combination of CO, SO2, NO, NO2 sensors, easy to upgrade

The results show that the conversion between percentage concentration, ppm, and mg/m3 is arbitrary

The measurement alarm limits for different gas components can be set separately

The internal special gas path design greatly reduces the loss of SO2 and NOx during testing

Automatically correct sensor cross interference based on smoke status

The large screen display and backlight function facilitate the normal use of the instrument in dim conditions

By measuring pressure, the flow rate of the flue gas is directly displayed

After booting up, you can directly enter the testing interface without pressing any keys, which is simple and convenient

Dual use of AC and DC, capable of continuous operation for 6 hours on a full charge

Data storage function

Infrared remote control printing method

Built in automatic calibration program facilitates users to calibrate themselves

Users can customize the printing content

Kane KM950 Handheld Smoke Analyzerparameter

parameter

resolution

accuracy

range

describe

Flue temperature

0.01ºC

0.01 ℃± 0.3% reading

0-1200ºC

>Using a high-temperature probe at 600 ℃

ambient temperature

0.01ºC

0.01 ℃± 0.3% reading

-50℃~50℃

pressure

1pa

± 2.0% reading

±15000pa

Over range ± 25000pa

Gas measurement

O2

0.01%

± 0.2% reading

0-25%

Except for O2 (which is a mandatory test item), users can choose 1-3 sensors from SO2, NO, NO2, and CO according to their needs. The measurement range can also be selected, but it is not possible to select the same sensor for two concentrations at the same time.

CO

1ppm

± 5% reading

0-10,000ppm

NO (standard range)

1ppm

± 5% reading

0-5000ppm

NO (low range)

1ppm

± 5% reading

0-200ppm

NO2

1 ppm

± 5% reading

0-1000ppm

SO2 (standard range)

1ppm

± 5% reading

0-5000ppm

SO2 (low range)

1ppm

± 5% reading

0-200ppm

Automatic calculation

CO2

0.1%

± 0.3% reading

0-99.9%

NOx

1ppm

± 5% reading

0-6000ppm

loss

0.1%

± 1.0% reading

0-99.9%

Combustion Efficiency

0.1%

± 1.0% reading

0-99.9%

Excess air coefficient

0.1%

±0.2%

0-2885.0%

Net temperature

0.01ºC

0.01 ℃± 0.3% reading

0-1200ºC

Smoke velocity

±0.1m/s

± 2.2% reading

2-45 m/s

Calculate based on flue pressure and temperature

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!