Principle&Structure
The KCP30 digital pressure transmission controller is an intelligent measurement and control product that integrates pressure measurement, display, contact control, and transmission output. It has an RS485 communication interface and can achieve network, digital signal transmission, and remote setting and calibration of transmitter parameters through the RS485 bus function. It can also be directly installed at on-site pressure measurement points, where multiple parameters such as zero point, full-scale value, contact pressure, and control pressure can be set on site using buttons. It accurately measures and controls on-site pressure, differential pressure, and liquid level, and provides intelligent multifunctional products with standard analog signals or contact control signals to other devices.

characteristic
Wide measurement range, all stainless steel structure high brightness LED pressure on-site display RS485 communication interface can provide up to four control contacts, contact value and contact status can be set arbitrarily, precise and reliable control;
application
Application of non corrosive gas and liquid pressure measurement for 316L stainless steel in industries such as petroleum, chemical, metallurgy, power, hydrology, etc
Technical Parameter
Range: | -1 to 0bar & 0 to 0.1bar & 0 to 1000bar |
Allow overload: | Less than or equal to 1.5 times the rated range or 1100 bar (taking the minimum value) |
Pressure type: | Gauge pressure, absolute pressure, sealing reference pressure type |
accuracy: | ±0.25%(0-100bar) ±0.5%(0-1000bar) |
Long term stability: | ± 0.3% F.S/year |
Zero temperature drift: | ±0.03%F.S/℃(≤1bar) |
±0.02%F.S/℃(>1bar) | |
Full temperature drift: | ±0.03%F.S/℃(≤1bar) |
±0.02%F.S/℃(>1bar) | |
Working temperature: | -20℃~80℃ |
Storage temperature: | -40℃~120℃ |
Power supply: | 24VDC or 220VAC |
Output signal: | Analog quantity 4-20mA; digital quantity RS485 |
Pressure interface: | M20 × 1.5&G1/2 or user selectable |
Relay control: | 1-4 channels control AC220V/3A |
Contact life: | More than 100000 times |
Display range: | -1999~9999 |
Installation method: | Vertical axial installation |
Shell material: | stainless steel |
Membrane material: | 316L |
O-ring seal: | VITON |
Cable: | polyethylene |
Insulation resistance: | 100MΩ 100VDC |
Shell protection level: | IP65 |
outline structure



Range code table
Standard Range Code Table (Unit: Bar) | Standard Range Code Table (in psi) | ||||
Standard range | Gauge pressure code | Absolute pressure code | Standard range | Gauge pressure code | Absolute pressure code |
-1…0bar | GB0 | / | 0…15psi | GP15 | AP15 |
0…1bar | GB1 | AB1 | 0…50psi | GP50 | AP50 |
0…2.5bar | GB2.5 | AB2.5 | 0…75psi | GP75 | AP75 |
0…4bar | GB4 | AB4 | 0…100psi | GP100 | AP100 |
0…6bar | GB6 | AB6 | 0…200psi | GP200 | AP200 |
0…10bar | GB10 | AB10 | 0…300psi | GP300 | AP300 |
0…20bar | GB20 | AB20 | 0…500psi | GP500 | AP500 |
0…40bar | GB40 | AB40 | 0…750psi | GP750 | AP750 |
0…60bar | GB60 | AB60 | 0…1000psi | GP1000 | AP1000 |
0…100bar | GB100 | AB100 | 0…2000psi | GP2000 | AP2000 |
0…160bar | GB160 | AB160 | 0…4000psi | GP4000 | AP4000 |
0…250bar | GB200 | AB200 | 0…7000psi | GP7000 | AP7000 |
0…400bar | GB400 | AB400 | 0…10000psi | GP10000 | AP10000 |
0…600bar | GB600 | AB600 | |||
0…1000bar | GB1000 | AB1000 |
Model Selection Table
KCP30- | Intelligent pressure controller | ||||||
measuring range | |||||||
Negative pressure -1 to 0 bar | |||||||
Gauge pressure (see range code table for range) (*) | |||||||
Absolute pressure (see range code table for range) | |||||||
measurement accuracy | |||||||
0.20% (0.2 level) | |||||||
0.50% (Level 0.5) (*) | |||||||
Process connection (external thread) | |||||||
M20×1.5 (*) | |||||||
G1/2 (*) | |||||||
G1/4 | |||||||
Other special threads | |||||||
Output main signal type | |||||||
4~20mA (*) | |||||||
0~10mA | |||||||
0~5V | |||||||
1~5V | |||||||
power supply | |||||||
24VDC±10% | |||||||
230VAC±10% | |||||||
Output auxiliary function signal | |||||||
One way relay | |||||||
Two way relay | |||||||
Three way relay | |||||||
Four way relay | |||||||
Four way relay with RS485 interface | |||||||
The selection form for appeal does not include selection codes. If you need a code, please contact us or fill in your information |
Note: (*) refers to spot or standing funds.