Shanghai Jinjiale Air Technology Co., Ltd
Home>Products>Jinjiale Spray Humidifier
Jinjiale Spray Humidifier
1. Fine mist particles 2, high efficiency 3, high self-control accuracy 4, wide application range
Product details
Introduction and application scope of the humidification section of the new spray air conditioner:
  
  The main features of the new spray section are:
  
1. Using a specially designed spray head, the mist particles are finer;
  
2. Using fillers to increase the contact area between steam and water results in higher efficiency;
  
3. Higher self-control accuracy and wider application range.
  
The spray room can heat, cool, dehumidify and humidify the air, filter dust, and absorb water containing gas (NH3'SO2) Among various processing functions, the seven major functions of the humidifier cannot be completely replaced by any type of humidifier, especially in harsh working conditions such as high temperature, dust, and fuzz. For example, in industries such as woolen textiles, cigarettes, chemicals, nuclear power equipment, cooling, etc., its disadvantages are that it occupies a large space, but its purification, cooling, low maintenance, and reliable operation characteristics are still irreplaceable in various humidification methods. Especially after improvement, the new spray air conditioner has a wider range of applications. Among them, the spray+wet film deformation combination method adopts a fine mist spray nozzle, which greatly reduces the occupied space area and greatly improves the cooling efficiency. In dry and hot climate conditions, the cooling can reach 10-15 ℃, and has great development and application prospects. In situations where high cleanliness and purity air quality are required, such as in the ultra clean integrated chip manufacturing industry, it is also used for the function of absorbing and filtering toxic and harmful gases, while reducing the cost of using activated carbon in the filtration section.




Jin JialeSpray humidifierWorking principle:

In the spray type, air and water molecules on the surface of the spray or wet film undergo frictional heat and moisture exchange to achieve humidification, cooling, absorption, dissolution, dust reduction, and water washing of the air. By changing the water temperature, dehumidification and humidification functions can be achieved.

Structure diagram
金嘉乐喷淋式加湿器 金嘉乐喷淋式加湿器
1. Front water baffle 2, nozzle and exhaust pipe 3, rear water baffle 4, water tank 5, cold water pipe 6, water filter 7, circulating water tank 8, three-way mixing valve 9, water pump 10, water supply pipe 11, water replenishment pipe 12, float valve 13, overflow device 14, overflow pipe 15, drain pipe 16, waterproof light 17, wet material 18, shell 19, water tank heat pipe




Features of Jinjiale Spray Humidifier:
  
1. Two types of circulation pump spray systems can be selected: internal or external, and one can be chosen according to the size allowed by the actual working conditions
  
2. Using stainless steel specialized nozzles, high pressure, high-density water distribution, fine mist particles, and obvious comprehensive functions
  
3. For high air volume (>150000 to 350000) air conditioning spray humidification and unique anti water technology, a special large groove water blocking plate is used, which can achieve<5m/s without water leakage
  
4. The filter system adopts dual stage filtration and backwashing technology to reduce cleaning and maintenance, and maintain unmanned operation.
  
5. For special large dust situations such as cigarette factories, there is a quick detachable double barrel filter that can be quickly replaced in 1 minute, saving operation time and making it convenient and durable
  
6. Automatic discharge function can be achieved based on water quality conductivity detection (optional)
  
7. Using a PLC controller to receive air conditioning interlock ON/OFF signals for remote control, with full Chinese display. Depending on the needs, a simple humidity controller can also be used
  



Control system:
  
1. Adopting Siemens (PLC) variable frequency proportional remote control and three control modes: manual, wet control, high, medium, and low
  
2. Automatic water inlet, quick water replenishment through the inlet valve,
  
3. Energy saving, high-precision humidity tracking: using spray frequency conversion control for humidification
  
4. Anti wave misoperation water level control to protect the water pump
  
5. Conductivity detection, automatic discharge
  
  


Control system diagram:
金嘉乐喷淋式加湿器




The seven major functions of the spray section+the function of washing harmful gases with water:
  
  The relationship between water temperature and air temperature and humidity determines various air treatment processes, as shown in the following figure:
  
T water=dew point T water=wet bulb T water=dry bulb
Isothermal cooling, isentropic humidification, isothermal humidification
金嘉乐喷淋式加湿器

  1. Dust removal and water washing functions for harmful gases
  
During the direct contact between water and air, harmful soluble gases (NH3/SO2) in the air dissolve in the water, while reducing the dust content of the air and improving its cleanliness, meeting the air quality requirements of certain high-purity electronic chip manufacturing processes.
  
  2. Cooling and heating functions
  
In summer, using groundwater or frozen water spray can achieve the purpose of air cooling and cooling, while using hot water spray can achieve the purpose of heating the air.
  
  3. Spray humidification function
  
To meet certain process environment humidity requirements, ensure product qualification rate, eliminate static electricity and other process requirements, such as humidification of automotive spraying lines, cooling equipment for power plant equipment, etc.
  
  Performance calculation parameters for spray room
  
Generally, the spray coefficient is used to represent the spray performance of the spray chamber, and other performance coefficients are used to represent the thermal performance of the spray type. The definition of the water vapor ratio U is the ratio of the amount of water sprayed to the amount of air, that is
  
U=W/GKG/KG, where:
  
W is the spray volume of the spray chamber, kg/h. The spray chamber usually uses a combination of U=W/G=1:1.5 spray and packing: U=W/G=1:0.5_1 is used
  
  Explanation of Air Treatment Status in Enthalpy Humidity Diagram

金嘉乐喷淋式加湿器

The relationship between water temperature and humidity determines the processing function(For mobile access, please click here

hydrograph Water temperature characteristics T or sensible heat D or latent heat I or total heat procedure name
A-1 tw<tl minus minus minus cooling dehumidification
A-2 tw<tl minus unchanged minus Cold temperature humidification
A-3 tl<tw<ts minus increase minus Enthalpy reduction and humidification
A-4 tw=ts minus increase unchanged Isentropic humidification
A-5 ts<tw<ta minus increase increase Enthalpy humidification
A-6 tw=ta unchanged increase increase Isothermal humidification
A-7 tw>ta minus increase increase Heating and humidification
tw: Water temperature tl: dew point temperature ts: wet bulb temperature ta: dry bulb temperature




Calculation of absorption efficiency for harmful gases such as NH3 and SO2:
  
Water soluble absorption of harmful gases such as NH3 and SO2, absorption efficiency: u={inlet outlet (ppm) value}/inlet air (ppm) value
  
For example, the content of SO2 in the air is 45ppm, and after spray absorption, it is 8ppm. The absorption efficiency is: u=(45-8/45)=82%
  
In order to improve absorption efficiency and reduce costs in the water system section, it is recommended to use a combination of spraying and filling materials, which can save costs, especially for the renovation of air conditioning, and also have multiple effects of humidification and cooling (detailed design information can be contacted with Jinjiale).




Model designation:
金嘉乐喷淋式加湿器
For example, JPL-50000-A-EE is equipped with a built-in spray humidifier for a 50000 air volume air conditioner





Classification of sprinkler systems:

1. The sprinkler room has a bedroom, a vertical type, and a combination type sprinkler room with a middle filling layer.
  
2. Nozzle layout: single-stage (single row, double row), two-stage (three row, four row)
金嘉乐喷淋式加湿器 金嘉乐喷淋式加湿器 金嘉乐喷淋式加湿器

3. The spray+filler combination spray chamber is equipped with a filler spray box inside the spray chamber, which independently completes the humidification and water distribution method. It can fully contact with water for heat and moisture exchange, and can shorten the length of the spray section. This type of spray room has a better air purification effect and is suitable for air conditioning renovation.
金嘉乐喷淋式加湿器 金嘉乐喷淋式加湿器





Product design structure form:

Two major categories

Class E - Configuration within the air conditioning spray humidification section - Class W - Integrated spray section docking
金嘉乐喷淋式加湿器 金嘉乐喷淋式加湿器

 1. Set type (E-type) configuration in the reserved spray section of the air conditioner
金嘉乐喷淋式加湿器
金嘉乐喷淋式加湿器 金嘉乐喷淋式加湿器
a. Supporting external circulating water pump (EY type)
  
b. Equipped with built-in submersible circulating water pump (EE type)

  2. Overall independent external stainless steel spray section (W-type)
金嘉乐喷淋死加湿器
金嘉乐喷淋死加湿器 金嘉乐喷淋死加湿器
a. Independently install external circulating water pump (WY type)
  
b. Independent installation with built-in submersible circulating water pump (WE type)




Spray water quality requirements:
  
Ordinary tap water, drinkable water or purified river water in the pool, weak alkaline water, cold and hot water, etc.




Ordering requires providing:
  
1. Airflow CHM: Total air quantity G Spray rate W (kg/h), Water vapor ratio=W/G
  
2. Initial and final states of air (required state): humidification/cooling/heating/washing/absorption purpose
  
3. Structure of sprinkler system: single-stage/two-stage/bedroom/vertical
  
4. Water temperature reference value (hot and humid treatment process)
  
5. Heat exchange efficiency: spray structure chamber, air mass flow rate (kg/m2 · S), spray volume
  
6. Control system: humidity control mode and automatic control programming: ordinary and variable frequency mode.
  
7. Spray form: traditional spray, high-efficiency mist spray
  
  Materials and selection of components for sprinkler system(For mobile access, please click here
Serial Number name Material and Model
1 Front and rear water barriers Stainless steel/PVC/fiberglass
2 Spray pipe Galvanized/Stainless Steel Pipe
3 water tank stainless steel
4 Water pump and valve components Domestic/imported models
5 Nozzle (material) PVC/Copper/Stainless Steel
6 Spray room shell Stainless steel/concrete/fiberglass
7 Wet wood Organic/lvheji/




Design considerations and model selection table:
  
1. The speed limit is greater than 3-<5m/s. A middle section should be installed behind the water blocking plate of the horizontal air conditioner, and a water-saving plate should be added to prevent "over water" and facilitate maintenance. The installation of filling materials can be avoided
  
2. The maximum wind speed is greater than 3.5 to less than 4m/s, and a special water blocking plate is used. Contact Jinjiale.

  Single stage double row spray section (Selection Table 1)


Airflow (CHM)
20000 30000 40000 50000 60000 80000 100000 120000 140000 160000 200000
Spray rate (T/h) 17.2 28.4 37.0 46.9 58.7 76.6 95.7 117.5 128.0 149.5 188.8
Cooling capacity (Kw) 90.6 141.8 191.7 240.6 297.9 391.8 489.7 596.8 664.5 758.5 973.2
Inlet pipe diameter DN1 40 50 65 65 65 80 80 100 100 100 125
Return pipe diameter DN2 65 80 80 100 100 125 125 150 150 150 175
Overflow pipe diameter DN3 80 100 100 125 125 150 150 175 175 200 250
Water replenishment pipe diameter DN4 20 20 25 25 32 32 40 40 40 40 40
Drainage pipe diameter DN5 32 40 40 40 40 50 50 50 65 65 65
Weight () 1905 2280 2620 2930 3295 3750 4410 5800 6300 6900 8100
Spray section length (mm) 2200-2600 1200-1500 (packing combination)
Air resistance (Pa) 60-75 130-140 (packing combination)
Nozzle model (mm) Diameter: 1-5
Number of nozzles According to project requirements
Nozzle pressure (Mpa) 0.15-0.8
Nozzle density 15-22 per square meter rows
Packing material PVC/Plastic/Aluminum Alloy/Stainless Steel
For mobile access, please click here

  Bipolar four row spray section and spray+wet film combination method(For mobile access, please click here):


Airflow (CHM)
20000 30000 40000 50000 60000 80000 100000 120000 140000 160000 200000
Spray rate (T/h) 34.3 56.8 73.9 93.7 117.5 153.1 191.4 235.0 256.1 291.7 377.5
Cooling capacity (Kw) 115.5 187.5 246.2 308.5 383.6 504.1 630.1 769.2 852.1 972.2 1552.2
Inlet pipe diameter DN1 40 50 65 65 65 80 80 100 100 100 125
Return pipe diameter DN2 65 80 80 100 100 125 125 150 150 150 175
Overflow pipe diameter DN3 80 100 100 125 125 150 150 175 175 200 250
Water replenishment pipe diameter DN4 20 25 32 40 40 50 50 50 65 65 65
Drainage pipe diameter DN5 40 50 50 50 50 65 65 65 80 80 80
Weight () 3045 3680 4205 4720 5310 5930 7075 7450 8000 8700 10200
Spray section length (mm) 2800-3200 1400-1800 (packing combination)
Air resistance (Pa) 70-80 130-140 (packing combination)
Nozzle model (mm) Diameter 1-5
Number of nozzles According to project requirements
Nozzle pressure (Mpa) 0.15-0.8
Nozzle density 15-22 per square meter rows
Packing material PVC/Plastic/Aluminum Alloy/Stainless Steel

  Saturation efficiency diagram of water flow changes in the combination of packing and spraying cooler, this scheme is used for equipment cooling purposes

金嘉乐喷淋式加湿器 金嘉乐喷淋式加湿器




Product usage case:

金嘉乐喷淋式加湿器 金嘉乐喷淋式加湿器 金嘉乐喷淋式加湿器
  





Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!