Shanghai Zhongrong Yidian Co., Ltd
Home>Products>Intelligent three-phase electricity inspection comprehensive tester (Bluetooth)
Intelligent three-phase electricity inspection comprehensive tester (Bluetooth)
Intelligent three-phase electricity inspection comprehensive tester (Bluetooth)
Product details



Main indicators
>Voltage 0-500V>current 5mA-10A
>Phase 0-360 degrees>frequency 45-65Hz
>Harmonic 2-32nd order>accuracy level 0.5/0.2

Main features
1. Equipped with a 7-inch 800 * 480 dot matrix TFT true color LCD display, with a graphical operation interface that can be operated by touch screen or buttons, and the interface display is clear and intuitive;
2. Automatic range switching function, no need for manual switching;
3. Verification methods for electric energy meters: single/three-phase active and reactive electronic energy meters, standard energy meters, mechanical energy meters, electromechanical integrated energy meters, prepaid energy meters, and multifunctional energy meters;
4. Electrical parameter measurement: measures AC voltage, current, power, electrical energy, frequency, phase, power factor, and can also measure the amplitude asymmetry and phase asymmetry of voltage and current, waveform distortion, and the pulse constant of the tested meter's electrical energy;
5. Data and graphic display: It can intuitively display the measurement work status and various measurement data. Can visually display measured voltage and current waveform diagrams, voltage and current phase vector diagrams, harmonic component histograms, and secondary circuit wiring diagrams;
6. Optional 500A or above current clamp can be used to detect the comprehensive error of low-voltage energy metering devices, as well as parameters such as low-voltage CT transformation ratio and angle difference;
7. Waveform display and harmonic analysis: It can measure the harmonic content and amplitude below the 31st order of voltage/current, and display them in a histogram;
8. Automatically identify wiring errors in P3/P4 energy meters, indicate the incorrect wiring location, display the secondary wiring diagram and power expression, and calculate the correction factor;
9. The wiring simulation function can be used as a training tool to improve the wiring skills of on-site personnel. The instrument can obtain corresponding wiring results based on on-site data without connecting voltage and current signals;
10. Record the error curve and display a schematic diagram of the error curve;
11. Power stability measurement;
12. Load curve recording (trend recording): Select any 4 data items such as voltage/current/frequency/power/power factor for recording;
13. Function of accumulating electrical energy and conducting character tests;
14. PT/CT settings can convert secondary data into primary data;
15. Calculation of voltage and current imbalance;
16. Vector calculator, on-site calculation of voltage and current vector sum;
17. Built in large capacity memory, capable of storing 5000 sets of measurement data;
18. The instrument is equipped with a USB interface, which can export measurement data through a USB flash drive and manage, store, and print detection reports on the computer;
19. The instrument is equipped with an RS232 interface, which can be connected to a computer to achieve real-time data transmission function;
20. The instrument is equipped with a 485 interface to read the energy data of a multifunctional energy meter (according to the national standard 645 protocol).
21. Optional Bluetooth wireless+APP dedicated software can synchronize data with Android phones or tablets to achieve functions such as data collection, storage, viewing, analysis, photography, and geolocation.

Product Usage
1. Electrical parameter measurement (U/I/Φ/P/Q/S/PF/Hz);
2. Discrimination of load characteristics between inductive and capacitive circuits;
3. Test the power consumption/power consumption of electrical equipment;
4. Single and three-phase power error verification;
5. Comprehensive measurement of low-voltage measuring devices;
6. Measurement of electricity quality in the power grid;
7. Load curve recording and online monitoring of load fluctuations;
8. Can be equipped with a high current clamp meter for power line loss management data collection;
9. Check the wiring of household meters and prevent electricity theft.
Technical indicators
1. Voltage measurement: 30-500V, resolution 0.001V, accuracy ± 0.2% or ± 0.5%
2. Current measurement: 5A clamp meter (overload 5% In-200% In), accuracy ± 0.2% or ± 0.5%
500A clamp gauge (overload 5% In-120% In), accuracy ± 0.5%
3. Active power/electrical energy measurement
5A clamp meter measurement: voltage 30V~500V, current 5% In~200% In, accuracy ± 0.2% or ± 0.5%
4. Reactive power/electrical energy measurement
5A clamp meter measurement: voltage 30V~500V, current 5% In~200% In, accuracy
±0.5% or ± 1.0%
5. Phase measurement: 0 °~359.99 °, resolution 0.01 °, accuracy 0.5 °
6. Frequency measurement: 45Hz~65Hz, resolution 0.001Hz, accuracy 0.01Hz
7. Power factor:- 1.0~0~+1.0,
8. Electric energy pulse: output pulse constant (r/kwh) pulse/kwh;
The constant input of the calibrated electric energy meter (r/kwh) is set within the range of 1 to 9999999
9. Operating environment: Temperature: -15 ℃ -45 ℃, Humidity: ≤ ± 85% RH, non corrosive gas
10. Power supply: PT borrowed AC 80-480V, power consumption ≤ 7.5VA
Lithium battery powered 7400mAh, working time>8 hours
11. Dimensions: 275 × 200 × 72mm, Weight: 1.5kg

Configuration Details
1. Standard configuration details:
1) 1 host
2) 3 5A clamp current transformers
3) 1 USB flash drive (4G)
4) 1 set of voltage testing line
5) 1 set of multifunctional photoelectric sampler
6) 1 pulse input/output line
7) 1 power adapter
8) 1 copy of user manual
9) 1 copy of factory inspection report
10) 1 copy of factory certificate/warranty card

2. Details of optional accessories:
1) VMP02 Mini Printer
2) 485 data cable
3) Backup lithium battery
4) 20A clamp current transformer
5) 100A clamp current transformer
6) 1000A clamp current transformer

7) 2000A clamp current transformer
8) Bluetooth wireless/APP dedicated software
Note: The selection of current clamps can be configured with up to 4 sets per host, and it is advisable to have a difference of 4 times the rated current between each set of current clamps!

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!