Working principle/working--------------------------------------------------------------------◆◆
|
The medium pressure is transmitted to the measuring diaphragm located at the center of the δ chamber through the isolation diaphragm and silicone oil. The measuring diaphragm is a tensioned elastic element that produces corresponding displacement with the pressure difference on both sides. The displacement of the measuring diaphragm is proportional to the differential pressure, with a maximum displacement of 0.1mm. It is detected by the capacitor plates on both sides, and the differential capacitance between the measuring diaphragm and the capacitor plate is converted into a two-wire (4-20) mA DC output signal using electronic circuits.
|
Structural composition/Structural components-----------------------------------------------------◆◆
|
|
1
|
Front cover of header
|
6
|
Explosion proof joint
|
11
|
splint
|
2
|
Header (Options)
|
7
|
connecting terminal
|
12
|
Sensor sealing ring
|
3
|
Metal cover
|
8
|
Header back cover
|
13
|
sensor
|
4
|
housing
|
9
|
Drain valve
|
14
|
nut
|
5
|
Nameplate label
|
10
|
bolt
|
15
|
Welded pipe joint component (option)
|
|
Product Features/Product features-----------------------------------------------------------◆◆
|
1. High precision
|
2. Good stability
|
3. Two line system 4-20mADC
|
4. Solid components, plug-in printed circuit boards
|
5. Small, lightweight, sturdy and earthquake resistant
|
6. Range and zero point are continuously adjustable externally
|
7. Positive migration can reach 500%; Negative transfer can reach 600%
|
8. Adjustable damping
|
9. Good one-way overload protection characteristics
|
10. Less maintenance workload without mechanical movable parts
|
11. Unified structure across the entire series, with strong interchangeability of components
|
12. The membrane material for contact with the medium can be selected from corrosion-resistant materials such as 316L, TAN, HAAS-C, MONEL, etc
|
13. Explosion proof structure, all-weather use
|
14. Intelligent HART fieldbus protocol
|
|
Performance parameters/performance parameters--------------------------------------------------◆◆
|
1. Target audience: liquids, gases, and vapors
|
2. Measurement range: 0-0.06kPa to 0-40MPa
|
3. Output signal: 4-20mA DC
|
4. 12-45VDC, usually 24VDC
|
5. Load characteristics: related to the power supply, the load capacity (load characteristics) at a certain power supply voltage, the relationship between load impedance RL and power supply voltage VS is: RL≤(VS-12)
|
6. Indicator: LCD or LFD digital display
|
7. Explosion proof: Explosion proof type dIIBT4 b: Intrinsic safety type iaIICT6
|
8. Range and zero point: externally continuously adjustable
|
9. Positive and negative transfer: After the zero point undergoes positive or negative transfer, the absolute values of the upper and lower limits of the range and measurement range cannot exceed 100% of the upper limit of the measurement range (intelligent type: range ratio 15:1). The maximum positive transfer is 500% of the minimum calibration range; The maximum negative transfer is 600% of the minimum tuning range
|
10. Temperature range: Amplifier operating temperature range: -29~+93 ℃ (LT type is -25~+70 ℃) Measuring element filled with silicone oil: -40~+104 ℃ Flange transmitter filled with high-temperature silicone oil:+15~+315 ℃, ordinary silicone oil: -40~+149 ℃
|
11. Static pressure: 1, 4, 10, 25, 32MPa
|
12. Temperature: Relative humidity is 0-100% RH
|
13. Volume change:<0.16cm ³
|
14. Damping (step response): When filled with silicone oil, it is generally continuously adjustable between 0.2s and 1.67s
|
|
Technical parameters/Technical parameters-------------------------------------------------------◆◆
|
(Without migration, under standard working conditions, filled with silicone oil, 316 stainless steel isolation diaphragm)
|
1. Accuracy: ± 0.075% (0 intelligent type), ± 0.1% (intelligent type), ± 0.25%, ± 0.5%
|
2. Dead zone: None (≤ 0.1%)
|
3. Stability: Absolute value of basic error not exceeding the maximum range within six months
|
4. Vibration effect: On any axis, the vibration frequency is 200Hz
|
5. Power supply impact: less than 0.005% V of the output range
|
6. Load impact: If the power supply is stable, the load is not affected
|
7. Installation position impact: Maximum zero point error of 0.24kPa can be generated
|
other
|
1. Isolation membrane: 316 stainless steel, Hastelloy C-276, Monel alloy, titanium or tantalum
|
2. Exhaust/Drain Valve: 316 Stainless Steel
|
3. Flanges and fittings: 316 stainless steel
|
4. Contact medium "O" ring: nitrile rubber, fluororubber
|
5. Filling fluid: silicone oil or inert oil
|
6. Bolt: 316L stainless steel
|
7. Electronic casing material: low copper aluminum alloy
|
8. Pressure connector: flange 1/4NPT, center distance 54mm; joint 1/2NPT or M20x1.5 male threaded ball cone seal, with center distance of 50.8, 54, 57.2mm when equipped with joint
|
9. Signal wiring hole: G1/2
|
|
Product selection/product selection------------------------------------------------------------◆◆
|
code
|
name
|
HH
|
Capacitive intelligent transmitter
|
|
code
|
describe
|
|
0
|
negative pressure
|
|
1
|
gauge pressure
|
|
2
|
Absolute pressure
|
|
code
|
measuring range
|
|
1
|
0-0.06~0.3KPa
|
|
2
|
0-0.25~1.5KPa
|
|
3
|
0-1.2~7.2KPa
|
|
4
|
0-6~36KPa
|
|
5
|
0-30~180KPa
|
|
6
|
0-160~1000KPa
|
|
7
|
0-400~2500KPa
|
|
8
|
0-1600~10000KPa
|
|
9
|
0-4000~25000KPa
|
|
0
|
0-7000~40000KPa
|
|
code
|
Type 1
|
|
0
|
Standard type
|
|
1
|
Single flat flange type
|
|
2
|
Double flat flange type
|
|
3
|
Single socket flange type
|
|
4
|
Double socket flange type
|
|
5
|
One flat and one inserted flange type
|
|
code
|
Flange specifications
|
|
0
|
DN25
|
|
1
|
DN50
|
|
2
|
DN80
|
|
3
|
Other specifications
|
|
code
|
Type 2
|
|
0
|
Common
|
|
1
|
Ordinary intelligent type (HART communication)
|
|
|
Code name
|
meaning
|
MO
|
Without display
|
M1
|
Digital indicator header
|
E1
|
Ordinary cable joint
|
E2
|
Explosion proof cable joint
|
B1
|
Pipe bending bracket
|
B2
|
Plate mounted bending bracket
|
B3
|
Pipe mounted flat bracket
|
G1
|
Waist flange
|
G2
|
Welded pipe joint
|
G3
|
Integrated three valve group
|
i
|
intrinsically safe
|
d
|
EEx d
|
G
|
≤ 200 ℃ (high-temperature silicone oil)
|
Standard type
|
Anticorrosive materials
|
Structural materials
|
Isolation Diaphragm
|
F12
|
316L
|
F13
|
Ha Shi C-276
|
F14
|
Monel K-500
|
F15
|
tantalum
|
F22
|
316L
|
F23
|
Ha Shi C-276
|
F24
|
Monel K-500
|
F25
|
tantalum
|
F26
|
316L
|
F33
|
Ha Shi C-276
|
F35
|
tantalum
|
F44
|
Monel K-500
|
F47
|
3YC25
|
|
Product dimensions/Product dimensions-----------------------------------------------------◆◆
|
|
|
SP3051 transmitter external dimension diagram
|
Measurement range (code)
|
2. 3, 4
|
6
|
7
|
8
|
9
|
M(mm)
|
54
|
52.2
|
55.7
|
57.2
|
59
|
|
Installation method/Installation method--------------------------------------------------------◆◆
|
|
Pipe bending bracket
|
Plate mounted bending bracket
|
|
|
|
Pipe mounted flat bracket
|
|
|
|
Pipe bending bracket
|
Plate mounted bending bracket
|
|
|
Pipe mounted flat bracket
|
|
|
Connection method of pressure pipe
|
|
|
Welded pipe joint connection
|
Integrated three valve group connection
|
|
|
Installation requirements/Installation requirements---------------------------------------------------◆◆
|
1. Prevent the transmitter from coming into contact with corrosive or overheated measuring media.
|
2. It is necessary to prevent debris from depositing inside the pressure pipe.
|
3. The pressure conduit should be as short as possible.
|
4. The liquid column pressure head inside the pressure guiding pipes on both sides should be kept balanced.
|
5. The pressure pipe should be installed in a location with small temperature gradients and fluctuations.
|
6. Prevent crystallization or low-temperature freezing inside the pressure pipe.
|
7. Do not unscrew all exhaust/drain valves to prevent the sealing steel balls from falling off!
|
|
Wiring Guide/Wiring guide-----------------------------------------------------------------◆◆
|
|
Connection of non intelligent on-site wires
|
|
|
|
|
|
|
|
|
|