Product Introduction
summary:
- Can simultaneously monitor 1-6 gases, with 17 sensors to choose from
- On site replacement of sensors
- iButton?On site location recognition
- Dot matrix LCD screen display with backlight
- The resolution of combustible gas detection can reach 50ppm
- Having LEL/CH4Over range protection function
- Using lithium-ion rechargeable batteries, the running time can reach 24 hours
- Optional iSP integrated sampling pump
ITX is a portable gas detector widely used by Industrial Scientific. One to six intelligent gas sensors can be configured according to the customer's needs for detecting gas types and quantities, and can be operated and calibrated with a single button. Suitable for various fields such as industrial safety, hygiene, and environmental protection.
ITX Multi Gas DetectorAdopting a background light spot array LCD display, it can simultaneously display the concentration of the measured gas. This instrument has a high brightness light alarm and a 90dB loud sound alarm. Stainless steel casing, durable and resistant to electromagnetic interference.
ITX Multi Gas DetectorIt has data recording function. The data recording capacity can reach 18000 sets, simultaneously recording S/TWA values, peak readings, and username/detection domain names. Can be used with iButton?On site location recognition, users can set 24 parameters as needed These parameters include security password settings, alarm value settings, and calibration method settings. The parameters of the instrument are set to regular values when it leaves the factory.
ITX can be connected to an integrated iSP sampling pump for remote monitoring, and daily maintenance can be carried out through the DS2 instrument management console.
Technical parameters:
Shell: |
304 stainless steel | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Size: |
121mm X 81mm X 43mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight: |
524.5 g | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sensor: |
Combustible gas/methane catalytic combustion type Oxygen and Toxic Gases - Electrochemistry |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Measuring gas types: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power supply (running time): |
Rechargeable lithium-ion battery pack (with a regular working time of 24 hours) Replaceable AA alkaline battery pack (with a regular working time of 12 hours) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Data recording volume: |
300 hours of recording time (with an interval of 1 minute) The data recording interval and data write coverage can be configured by users themselves |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Data input volume: |
16 character user and on-site data can be entered using a keyboard IButton automatic data entry function (optional) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature range: |
-20°C~50°C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Humidity range: |
15-95% RH (non condensing) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
performance |
advantage |
Up to five on-site replaceable sensors |
Provide flexible monitoring for various applications. Reduce related operating costs and downtime |
|
|
50ppm hydrocarbon (HC) resolution, reaching the lower explosive limit (LEL) alarm set point. |
Users can accurately monitor low levels of hydrocarbons |
|
|
LEL/CH4Sensor over range protection function |
When the sampled gas concentration exceeds 100% LEL or 5.0% Vol CH4Automatically close LEL/CH4Power supply, thereby extending the lifespan of sensors, ensuring the integrity of calibration, and low-cost component replacement |
|
|
Four electrode ammonia gas (NH)3 )Sensors |
Enhance the stability and prolong the lifespan of ammonia gas sensors, thereby improving the efficiency of operators and reducing their operating costs |
|
|
Reusable lithium-ion and alkaline battery packs |
The power supply provides users with all-weather monitoring performance |
|
|
The operating system can be configured by the user themselves |
Users can adjust the instrument for specific display, alarm, calibration, data recording, and other instrument operations as needed |
|
|
Simultaneously display the monitored gas |
Reliable performance, easy to use, and operators can instantly check gas readings to ensure continuous and uninterrupted operation of the equipment |
|
|
What about DS1000 Docking Station? compatible |
Can automatically calibrate, record data, reduce the total operating cost of instruments, and ensure the correctness of archives |
|
|
One click operation and calibration |
Simplify training procedures, reduce the time and calibration gas required for each calibration operation |
|
|
Quick calibration function |
When using a mixed calibration gas, the quick calibration function will calibrate all sensors simultaneously, saving time, gas, and cost |
|
|
The radio frequency interference (RFI) protection function has been certified by a third party to the European standard EN50081-2. |
Eliminate harassing readings and alarms while improving work efficiency |
|
|
Calibration and alarm settings are protected by passwords. |
Safe to use, non trained personnel will not perform instrument setup or calibration |
|
|
Peak/hold value mode |
Users can track and query the peak exposure of gases during the homework period or at the end of the shift. No tedious data recording is required to track and query the gas exposure values that workers are exposed to. |
|
|
External integrated sampling pump (optional) |
The detector can be used for personal monitoring and remote sampling in confined spaces. No additional batteries or charging devices are required when using the integrated pump |
|
|
Stainless steel structure |
Durable, strong resistance to radio frequency interference, reduced maintenance costs and downtime |
|
|
Delay alarm function (103 decibels) |
Provide danger warning in high noise environments, with external 103 decibel auditory and visual or vibration alarm functions |
|
|
iButton。 On site data entry function |
Automatically leave user and location information on the data logger for easy verification of gas survey data |
|
|
Can record up to 300 hours of data (with an interval of 1 minute) |
The large data capacity can provide data storage space for long-term rotations of more than a month, ensuring data continuity before memory runs out |
|
|
The data recording/hygiene functions can be configured by users themselves. |
Users can configure data recording intervals, read-write coverage functions, automatic event recording, and Time Weighted Average (TWA) parameters to provide customized monitors for specific applications |
enclosure:
Part number |
explain |
|
|||||||||||||||||||||||||||||||
18105551-ABC+ |
ITX dedicated DS2 instrument calibration management unit |
|
|||||||||||||||||||||||||||||||
18104315 |
ITX Small Single Unit Charger, Universal |
|
|||||||||||||||||||||||||||||||
18105296 |
ITX small standalone charger, 12VDC |
|
|||||||||||||||||||||||||||||||
18104737-120 |
ITX charger with data acquisition kit, 120 VAC |
|
|||||||||||||||||||||||||||||||
18104737-230 |
ITX charger with data acquisition kit, 230 VAC |
|
|||||||||||||||||||||||||||||||
18104737-12 |
ITX charger with data acquisition kit, 12 VDC |
|
|||||||||||||||||||||||||||||||
18104711-120 |
ITX charger/data cable, 120 VAC |
|
|||||||||||||||||||||||||||||||
18104711-230 |
ITX charger/data cable, 230 VAC |
|
|||||||||||||||||||||||||||||||
18104711-12 |
ITX charger/data cable, 12 VDC |
|
|||||||||||||||||||||||||||||||
18105379 |
Six machine charger with iTX cable and bracket (universal input) |
|
|||||||||||||||||||||||||||||||
18104646 |
ISP electric sampling pump |
|
|||||||||||||||||||||||||||||||
18105189 |
Constant current manual pump for iTX |
|
|||||||||||||||||||||||||||||||
17088618 |
Backup battery pack, rechargeable lithium-ion battery |
|
|||||||||||||||||||||||||||||||
17089376 |
Backup battery pack, replaceable "AA" alkaline battery |
|
|||||||||||||||||||||||||||||||
18104729 |
iButton?Programming kit, AC voltage: 120V |
|
|||||||||||||||||||||||||||||||
18105080 |
iButton?Programming kit, AC voltage: 230V |
|
|||||||||||||||||||||||||||||||
17096348 |
iButton?Data memory unit with installation card |
|
|||||||||||||||||||||||||||||||
17090333 |
iButton?Data memory component |
|
|||||||||||||||||||||||||||||||
18104703 |
ITX Leather Carrying Bag |
|
|||||||||||||||||||||||||||||||
16000039 |
ITX maintenance and training videos, VHS |
|
|||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||
|