ISO16890 filter materialtest system
The filter material testing system consists of the following components:
aerosol generator
aerosol spectrometer
Dilution device
piping
Analysis software
Different system configurations can be used to test filter media, small filter elements, high-efficiency filters, general ventilation filters, compressed air filters, vehicle air filters, and oil mist separators. Special configurations can meet system testing under high temperature and high humidity conditions.
Technical parameters:
Volume flow rate: 1-35 m3/h
Surface velocity: 1-100 cm/s
Pressure drop measurement: 0-2500 Pa
Medium surface area: 100 cm2
Aerosol type: dust (such as SAE dust); Salt (such as NaCl, KCl); Droplets (such as DEHS)
Particle measurement range:
welas ® - 1000:0.2 – 9 μm; 0.25 – 17μm; 0.6 – 40 μm;
welas ® - 2000:0.3 – 17μm; 0.7 – 40μm
Aerosol concentration: above 1000 mg/m3 (for SAE dust)
Dimensions WxHxD: 600 x 1800 x 900 mm
Power supply: 220V/50Hz
Main features:
There are also MFP-2100, MFP-3000, and EN143/EN1822 filter material testing systems available for selection; The provided filter testing system complies with the following standards: general ventilation air filter testing system EN779/ASHRAE52.2, vacuum cleaner testing system DIN33891, automotive air filter testing system DIN71460, oil mist separator testing system HMT-1000, and scanning high-efficiency filter leak detection and efficiency testingFixed system