1、 Overview of Pipeline Pump Products IHG (ISG) series single-stage single suction pipeline centrifugal pump adopts the performance parameters of IS t
Product details

working conditions
1. Suction pressure ≤ 1.0MPa, or high working pressure of pump system ≤ 1.6MPa
The pump suction pressure+pump head is ≤ 1.6MPa, and the pump static pressure test pressure is 2.5MPa
Please specify the system operating pressure when placing an order. When the working pressure of the pump system is greater than 1.6MPa, it should be separately stated when ordering.
2. The ambient temperature is ≤ 40 degrees and the relative humidity is ≤ 95%.
3. The volume content of solid particles in the conveyed medium shall not exceed 0.1% of the unit volume, and the particle size shall be less than 0.2mm.
Note: If the medium used contains small particles, please specify when placing an order.
The significance of ISG pipeline centrifugal pump model
For example: ISG100-160(I)AB
ISG vertical centrifugal pump
100- nominal diameter of pump inlet and outlet (mm)
160- nominal diameter of impeller (mm)
I-Traffic Classification
AB impeller undergoes first and second cutting
Parking:
1. The high-temperature type should first cool down, with a cooling rate of ∠ 10 ℃/min. Reduce the temperature to below 80 ℃ before parking.
2. Close the valve of the discharge pipeline.
3. Turn off the power.
4. Close the inlet valve.
5. If parking for a long time, the liquid in the pump should be drained completely.