IC card prepaid metering management system
Product description: Prepaid function: solves the problem of difficult charging at present. When the user's remaining flow is insufficient, the contac
Product details
Product Description:
Prepaid function: solves the current problem of difficult charging by disconnecting the contactor and preventing the water pump from starting when the user's remaining flow is insufficient.
Scientific measurement: Accurately measuring the actual sewage discharge through flow meters is more scientific and accurate than estimating flow rates.
Real time monitoring: Through remote data collection, users' emissions can be timely monitored for scientific scheduling and dynamic management.
On site alarm function: When the remaining flow is insufficient, the light alarm is activated to prompt the user to pay in a timely manner.
SMS reminder function: When there is not much remaining data, the system sends a text message to the user to urge payment.
Prepaid function: solves the current problem of difficult charging by disconnecting the contactor and preventing the water pump from starting when the user's remaining flow is insufficient.
Scientific measurement: Accurately measuring the actual sewage discharge through flow meters is more scientific and accurate than estimating flow rates.
Real time monitoring: Through remote data collection, users' emissions can be timely monitored for scientific scheduling and dynamic management.
On site alarm function: When the remaining flow is insufficient, the light alarm is activated to prompt the user to pay in a timely manner.
SMS reminder function: When there is not much remaining data, the system sends a text message to the user to urge payment.
Technical parameters:
4.2.1 Instrument error
Test conditions: Preheat for more than 5 minutes when powered on to achieve optimal accuracy.
Flow digital sampling with arbitrary error<0.05%:
Flow simulation signal, any industrial control error<0.2%
Frequency signal, any industrial control error<0.1%
4.2.2 Input signal
Analog quantity: (2-4 channels) Voltage: 1-5V Current: 4-20mA
Thermistor: (1-2 channels) Pt100, Pt1000
Pulse quantity: (1 channel) Waveform: rectangular wave, sine wave, or triangular wave
Amplitude: Low level 0-2V, high level 5-24V
Frequency: 0-10KHz
Sensor distribution: 24VDC or 12VDC, with distribution output current limiting protection
4.2.3 Communication Interface
Number of interfaces: (1-2 channels)
Interface type: Optoelectronic isolation RS232 or Optoelectronic isolation RS485
Communication speed: 1200240048009600 can be set
Communication protocol: Modbus or other
4.2.4 Flow transmission output (1 channel)
Analog output: 4-20mA/0-10mA adjustable, load resistance 0-600 ohms, data update time ≤ 1S, error ± 0.2%
Frequency output: 0~10KHz, duty cycle 50%, error ± 1HZ
4.2.5 Sampling Error
Frequency signal input: ± 1HZ
PT100 signal input: ±0.2℃
Voltage and current analog signal input: ± 0.1%
4.2.6 Power outage record
Automatically record the last 32 power off/on times
4.2.7 Display Capability
High definition white background with black text 128 × 64 LCD display screen, fully displaying in Chinese.
4.2.8 Power outage data storage time: theoretically not less than 10 years
4.2.9 AC power supply: 220VAC, 50HZ, ± 20% (AC power supply model)
4.2.10 DC power supply: 9V~16V (DC power supply model)
4.2.11 Power consumption: less than 10W
4.2.12 Environment: Operating temperature: -20~60 ℃ Relative humidity: 0~85%
4.2.1 Instrument error
Test conditions: Preheat for more than 5 minutes when powered on to achieve optimal accuracy.
Flow digital sampling with arbitrary error<0.05%:
Flow simulation signal, any industrial control error<0.2%
Frequency signal, any industrial control error<0.1%
4.2.2 Input signal
Analog quantity: (2-4 channels) Voltage: 1-5V Current: 4-20mA
Thermistor: (1-2 channels) Pt100, Pt1000
Pulse quantity: (1 channel) Waveform: rectangular wave, sine wave, or triangular wave
Amplitude: Low level 0-2V, high level 5-24V
Frequency: 0-10KHz
Sensor distribution: 24VDC or 12VDC, with distribution output current limiting protection
4.2.3 Communication Interface
Number of interfaces: (1-2 channels)
Interface type: Optoelectronic isolation RS232 or Optoelectronic isolation RS485
Communication speed: 1200240048009600 can be set
Communication protocol: Modbus or other
4.2.4 Flow transmission output (1 channel)
Analog output: 4-20mA/0-10mA adjustable, load resistance 0-600 ohms, data update time ≤ 1S, error ± 0.2%
Frequency output: 0~10KHz, duty cycle 50%, error ± 1HZ
4.2.5 Sampling Error
Frequency signal input: ± 1HZ
PT100 signal input: ±0.2℃
Voltage and current analog signal input: ± 0.1%
4.2.6 Power outage record
Automatically record the last 32 power off/on times
4.2.7 Display Capability
High definition white background with black text 128 × 64 LCD display screen, fully displaying in Chinese.
4.2.8 Power outage data storage time: theoretically not less than 10 years
4.2.9 AC power supply: 220VAC, 50HZ, ± 20% (AC power supply model)
4.2.10 DC power supply: 9V~16V (DC power supply model)
4.2.11 Power consumption: less than 10W
4.2.12 Environment: Operating temperature: -20~60 ℃ Relative humidity: 0~85%
Application scope:
Petroleum, chemical, textile, metallurgy, mining, light industry, medicine, electricity, environmental protection, municipal, food and scientific research fields, etc
Petroleum, chemical, textile, metallurgy, mining, light industry, medicine, electricity, environmental protection, municipal, food and scientific research fields, etc
Online inquiry