Brand and model: Changsha Weisheng DTS (X) 343-3 three-phase four wire reactive power combination meter
Wiring system: three-phase four wire system
Current specification: 3 × 1.5 (6) A
Frequency: 50Hz
Multiple rate: None
Communication protocol: DL/T645-1997 protocol
Meter attribute: Three phase four wire electronic reactive power combination meter
Accuracy level: Active level 1; Reactive power level 2
Voltage specifications: 3 × 220/380V 3 * 57.7/100V
Product dimensions: length x width x thickness: 238mm x 148mm x 80mm
Communication interface: 1 RS485 interface; Far infrared communication interface
Active pulse constant 10000imp
Reference frequency 50Hz
Voltage working range ± 20% Un
Clock error ≤ 0.5/s/d
Clock frequency 1Hz
Mean time between failures ≥ 6 × 104h
Power consumption ≤ 1.5W, 7VA
Environmental temperature (-25~+65) ℃
Extreme temperature (-35~+75) ℃
Product design lifespan>10 years
Backup battery life ≥ 3 years
Pulse width of electric quantity (100 ± 10) ms
Electric pulse voltage DC (5-24) V
The net weight of a single machine is about 2kg
DTS(X)343-3It is an ideal replacement product for mechanical energy meters, with power and reactive power metering functions, strong overload capacity, good stability, and high reliability.
● Dual row LCD display with power-off constant display function
● Supports RS485 communication and far-infrared communication
Measure positive and negative active power, with negative active power being included in the positive calculation; Phase wise positive and negative active power consumption
Measure the combined reactive power in both forward and reverse directions, as well as the reactive power in four quadrants; Split phase positive and negative reactive power consumption
● Automatic monthly settlement function, which can save historical electricity data of active and reactive power for the past 12 months
Measure instantaneous quantities such as phase separation voltage, current, and reactive power
● Alarm prompts and zero reset event records for phase failure, reverse, and reverse phase sequence faults
Technical parameter project | Project Content |
technical standard | GB/T17215.321-2008 GB/T17215.323-2008 |
accuracy class | Merit: Level 1; Reactive power: Level 2 |
reference voltage | 3×220/380V; 3×57.7/100V; |
Current specifications | 1.5(6)A ; |
communication protocol | DL/T645-1997 |
Overall Power Consumption | <1.5W; 6VA |
reference frequency | (50±2.5)Hz |
Working voltage range | 0.8Un~1.3 Un; |
operation temperature | -25℃~+55℃ |
Extreme operating temperature range | -35℃~+65℃ |
External dimensions | Length x Width x Thickness: 238mm x 148mm x 80mm |
net weight | About 2.0kg |