VIP member
High pressure flange level transmitter
High pressure flange level transmitter
Product details
The high-pressure flange level transmitter is a new type of transmitter produced by our company through the introduction of advanced foreign technology and equipment. The key raw materials, components, and parts are all imported, and the whole machine has undergone strict assembly and testing. This product has advanced design principles, complete varieties and specifications, and simple installation and use.
High pressure flange level transmitter is suitable for continuous measurement of liquid level (material level) in various high-voltage equipment and containers in industrial production processes. It can transmit and output 4-20mA DC standard signals and can be directly used for electrical type III instruments and computer connection, automatic control, etc. The probe uses special materials that can work for a long time in an environment of 250 ℃. Its unique automatic sealing structure ensures stricter sealing with higher pressure, completely preventing medium leakage.
High pressure liquid level transmitter
Technical parameters of high-pressure flange level transmitter:
Object of use: Liquid
Measurement range: Range 40-1.0~37.4kPa (0-96~3810mmH2O)
Range: 50-4.7~186.8 kPa (0-477~19050mmH2O)
Range: 60-17.3-690kPa (0-0.18-7kgf/cm2)
Output signal: Linear output: 4~20mA output combined with HART ® Protocol digital signal (two-wire system)
Power supply: External power supply 24V DC, (power range 12V~45V)
Load characteristics: The maximum load resistance allowed by the load resistance circuit is Rmax=(E-12)/0.02 (Ω)
Installation in hazardous areas: Explosion proof type dllCT6; Intrinsic safety type iallCT5
Load characteristics: Regardless of the output, after positive and negative migration, the upper and lower limits of the range must not exceed the limit of the range.
Temperature range: medium temperature -40~149 ℃ (filled with silicone oil)
Storage temperature -18~204 ℃ (filled with inert liquid)
The working temperature of the whole machine is -40~85 ℃ -20~70 ℃ (with digital meter head);
Relative humidity of liquid level transmitter: 0-100%
Static pressure and overpressure limit: 150lb flange: 41.37kPa (absolute pressure)~4.9Mpa (at 37 ℃, filled with silicone oil)
300lb flange: 41.37kPa (absolute pressure)~4.9Mpa (at 37 ℃, filled with silicone oil)
Volume change: less than 0.16cm3
Damping: The time constant can be adjusted between 0.2 and 32.0s (at 37 ℃, filled with silicone oil).
Start time: 3 seconds, no preheating required.
Online inquiry