High and low temperature alternating humidity test chamber JX-PRHT-100L
1、 Scope of application of high and low temperature alternating humidity test chamber
Suitable for testing the performance indicators of aerospace products, information electronic instruments, materials, electrical and electronic products, and various electronic components in high and low temperature environments. Applied to the defense industry and aerospace industry The test specifications for heat resistance, cold resistance, dry resistance, and quality management engineering of automation components, automotive parts, electronic and electrical components, instruments, materials, plastics, chemical, food, pharmaceutical industries, and related products evaluate the adaptability and characteristics of the tested products under given environmental conditions.
2、 Technical parameters of high and low temperature alternating humidity test chamber
Machine model |
JX-PRHT-80 |
JX-PRHT-100 |
JX-PRHT-150 |
temperature range |
-70℃~+150℃ |
temperature fluctuation |
≤±0.5℃ |
Temperature Uniformity |
≤±2.0℃ |
|
warm-up time
|
-20 ℃~+150 ℃, within 50 minutes
-40 ℃~+150 ℃, within 60 minutes
-70 ℃~+150 ℃, within 75 minutes
|
|
Cooling time
|
+20 ℃~-20 ℃, within 45 minutes
+20 ℃~-40 ℃, within 65 minutes
+20 ℃~-70 ℃, within 95 minutes
|
|
Dimensions inside the box
Unit centimeter
|
W40
H50
D40
|
W50
H50
D40
|
W50
H60
D50
|
|
Outer dimensions of the box
Unit centimeter
|
W60
H141
D115
|
W70
H141
D115
|
W70
H151
D125
|
heating power |
2.2KW |
2.6KW |
2.6KW |
Humidification power |
1.8KW |
2KW |
2KW |
|
Partition load capacity
quantity
|
Single layer load capacity 8KG
(2 pieces)
|
Single layer load capacity 10KG
(2 pieces)
|
Single layer load capacity 10KG
(2 pieces)
|
Total weight of the machine |
280KG |
320KG |
400KG |
Power connection method |
Single phase 3-wire
220V50HZ
|
Single phase 3-wire
220V50HZ
|
Three phase 5-wire
380V50HZ
|
3、 Product characteristics of high and low temperature alternating humidity test chamber
1. High definition true color LCD touch screen, temperature control adopts P · I · D+S · S · R system for coordinated control of the same channel; It has the function of automatic calculation, programmable and massive storage of historical data and curves. Equipped with USB port and Ethernet terminal interface, and supporting real-time computer monitoring
Historical curve playback, program editing, FTP upload and download, historical fault viewing, remote setting/program control and other functions.
2. The refrigeration system adopts the original French Taikang compressor unit, and the refrigerant adopts the American DuPont brand, with strong refrigeration effect and stable performance.
3. The core electrical components are all imported from well-known brands such as Schneider and Omron.
4. Following the advanced design concept of foreign environmental testing equipment, water and circuit are completely separated, making operation and use safer.
5. Unique leakage protection design ensures safer operation.
6. Focus on details, anti rust design for lead testing holes, Japanese imported silicone rubber sealing strips to ensure sealing effect, and high-quality fixed PU caster design.
7. The observation window adopts multi-layer insulated tempered glass, and the inner side is coated with laminated conductive film for heating and defrosting (clearly observe the test process)
8. The test hole (on the left side of the machine) can be used for external testing power or signal lines (the aperture or number of holes needs to be increased and indicated)
Dongguan Jiuxing Electronic Technology Co., Ltd
contacts; Xiao Ling
Telephone;
www.gaodiwenxiang.com
QQ;280107575