RY type heat transfer oil pump - Product Overview
LQRY typeHeat conducting oil pumpIt is developed by absorbing the characteristics of various advanced hot oil circulation pumps at home and abroad. This pump has the characteristics of reasonable structure, advanced technology, high efficiency, long-term stable operation without leakage in hot state, and no additional cooling system, which is safe and reliable. It can be widely used in industrial fields such as petroleum, grease, boilers, construction, road maintenance, pharmaceuticals, plastics, rubber, fiber containing textiles, printing and dyeing. It is mainly used to transport weakly corrosive high-temperature liquids without solid particles. The operating temperature is ≤ 370 ℃, which is an ideal choiceoil pump.
RY type heat transfer oil pump - model meaning
LQRY型导热油泵型号意义
RY type heat transfer oil pump - structural characteristics

The RY type hot oil pump (thermal oil pump) is the second generation product developed by our unit based on the digestion and absorption of foreign oil pumps. The basic structural form is a single-stage single suction cantilever foot support structure,pumpThe inlet is for axial suction, and the outlet is vertically upward from the center, installed on the base together with the motor.
RY typehot oil pumpThe support of the heat transfer oil pump adopts a double ended ball bearing structure, with lubricating oil lubrication at the front end and grease lubrication at the rear end. There is a guide oil pipe in the middle to observe the sealing condition and recover the heat transfer oil at any time. Adopting a self heating heat dissipation structure, it changes the traditional water cooling structure, making the structure simple, small in size, saving operating costs, good in performance, and reliable in use.
The RY type hot oil pump (heat transfer oil pump) adopts a combination of packing seal and mechanical seal. The packing seal uses highly resistant packing with good thermal adaptability, while the mechanical seal uses hard alloy material with high mechanical strength and good wear resistance to ensure sealing performance under high temperature conditions.
(2) The use of third-generation polytetrafluoroethylene (PTFE) as a lip seal has led to a significant improvement in sealing performance, making it more reliable than rubber seals. It is 25 times more effective and has extremely strong corrosion resistance.

RY type heat transfer oil pump - structural diagram
LQRY型导热油泵结构图

1 pump body 2 CAP NUT 3 impeller 4 plug screw 5 Aluminum heating ring
6 flat key 7 pumpcover 8 Elastic stop ring for holes 9 Aluminum washer 10 pressing ring
11 padding 12 nut 13 grommet 14 bolt 15 bolt
16 Pump shaft 17 ball bearing 18 bearing housing 19 shim 20 Aluminum plate
21 rivet 22 mechanical seal 23 bolt 24 Enzyme 25 grommet
26 Oil guide pipe 27 screw 28 grommet 29 rubber seal 30 Bearing cap
31 shim 32 Pump coupling 33 flat key 34 Elastic block 35 Motor coupling
36 housing 37 screw 38 motor 39 bolt 40 Stud
41 grommet 42 base 43 grommet 44 circlip

RY typeHeat conducting oil pump--Performance parameters

model
RY
internet traffic
m3/h
lift
m
rotational speed
r/min
Power KW efficiency
n%
net positive suction head
NPSH
m
shaft power Matching
power
26-20-100 4.5 15 2825 0.45 0.75 40 0.8
50-32-150 8 22 2840 1.0 1.5 42 1.6
50-32-160 10 25 2840 1.5 2.2 42 1.8
65-40-160 12.5 25 2880 2.5 3 45 2.2
50-50-170 12.5 32 2890 3.2 4 45 2.5
65-50-180 32 32 2900 4.5 5.5 52 2.7
65-50-170 40 25 2900 4.5 5.5 52 2.7
80-50-180 40 40 2900 6.7 7.5 63 3.1
80-50-170 60 20 2900 6.7 7.5 63 3.1
100-65-190 60 38 2930 9.2 11 68 3.9
100-65-200 80 40 2930 12.5 15 70 3.5
100-65-220 58 50 2930 12.5 15 68 3.5
100-65-230 l00 55 2940 19.5 22 70 3.6
125-100-190 155 30 2940 20 22 72 3.6
100-65-240 100 70 2950 25.5 30 69.8 4.1
100-65-257 100 80 2950 32.5 37 67 3.6
125-100-220 160 45 2950 25.5 37 75.2 3.6
125-80-250 160 60 2970 35.5 45 74.2 5
125-100-250 200 60 2970 42.8 55 76.8 6
125-100-257 260 70 2970 64.3 75 77.1 6.8
125-100-260 300 70 2970 75.3 90 78.2 8
125-100-270 220 85 2970 68 90 76 6
150-125-270 340 76 2970 89.5 110 78.6 8.5
150-125-270 400 7.8 2970 106 132 80.6 9.8

RY typeHeat conducting oil pump--Installation size
LQRY型导热油泵--安装尺寸

Oil pump Model
RY
electrical machinery
Machine base number/power
oil pumpAppearance and installation dimensions
L L1 L2 L3 B1 B2 B3 A a h1 h2 H1 H2 D1 D2 nl/dl n2/d2 N3/d3
26-20-100 Y801-2/0.75 700 630 108 415 200 230 270 75 80 95 25 290 180 85 75 4/14 4/14 4/14
50-32-150 Y90S-2/1.5 800 700 80 525 180 248 295 80 90 132 40 365 210 125 100 6-17.5 4-17.5 4-16
50-32-160 Y90L-2/2.2
65-40-160 Y100L-2/3 1000 810 110 590 280 360 410 100 150 420 240 145 110 8-17.5 4-20
50-50-170 Y112M-2/4 845 122.5 600 355 360 410 152 442 247 125 6-17.5
65-50-180 Y132S1-2/5.5 1100 900 120 660 300 380 440 160 410 245 160
80-50-180 Y132S2-2/7.5
100-65-190 Y160M-2/ll 1200 1049 730 355 440 510 110 120 180 510 285 180 145 8-20 8-17.5 4-22
100-65-220 Y160M1-2/15
100-65-200A Y160M1-2/15
100-65-230 YlSOM-2/22 1300 1180 145 930 415 495 570 115 125 200 570 320
125-100-200 Y180M-2/22 220 180
100-65-240 Y200L1-2/30 1400 180 145
100-65-257 Y200L2-2/37
125-100-220 Y200L2-2/37 220 180
125-80-250 Y225M-2/45 1513 1245 152 480 540 620 140 144 225 45 620 345 160 8-22 4-24
125-100-250 Y250M-2/55 1580 1400 230 550 600 690 654 370 190 8-22
125-100-257 Y280S-2/75 1628 1510 275 960 540 620 695 150 230 50 725 438
125-100-260 Y280S1-2/90
125-100-270 Y280S1-2/90 1628 1510 275 990 540 620 695 150 144 230 50 725 438 220 190 8-22 8-22 4-24
150-125-270 Y315S-2/110 1818 1590 250 1090 628 720 780 145 150 230 45 750 440 240 210 8-22 8-17.5 4-24
150-125-270 Y315M1-2/132 1888

RY typeHeat conducting oil pump--Installation and use

Installation and use of RY type hot oil pump (thermal oil pump)
The quality of pump installation has a significant impact on the smooth operation and service life of the pump, so installation work must be carried out carefully and not hastily.
2.water pumpThe installation height, length, and diameter of the suction pipe should meet the calculated values, striving for simplicity and reducing unnecessary losses (such as bends).
3. The suction and discharge pipelines should have pipe racks, and the pump is not allowed to bear the load of the pipelines.
4. The installation location should be spacious enough to facilitate maintenance work and good heat dissipation.
5. Installation sequence:
(1) Place the unit on a foundation with embedded anchor bolts, and place a pair of pads between the base and the foundation for reference.
(2) Loosen the coupling and place a spirit level on the pump shaft and base respectively. Adjust the wedge pad to make the unit level. After aligning, tighten the anchor bolts appropriately to prevent movement.
(3) Pour concrete into the base and anchor bolt holes.
(4) After the concrete has dried and solidified, check whether there are any defects or looseness in the base and anchor bolts. After passing the inspection, tighten the anchor bolts and recheck the levelness of the pump.
(5) Correct the coaxiality of the pump shaft and motor shaft. The deviation on the outer circle of the coupling is allowed to be 0.1 millimeters, and the gap between the two coupling planes should be ensured to be 2-3 millimeters. The maximum and minimum gap difference around the end faces of the two couplings should not exceed 0.3 millimeters.
(6) After connecting the pipeline and determining the direction of rotation of the prime mover, connect the coupling again and verify the coaxiality of the circle.
(7) After 3-4 hours of actual trial operation of the unit, a final inspection shall be conducted. If there are no adverse phenomena, the installation is considered qualified.
(8) To prevent debris from falling into the machine during installation, all holes in the unit should be covered.
(9) When cleaning the inlet and outlet pipelines before starting the pump, a filter should be added to the inlet section of the pump to prevent debris from entering the pump.
Disassembly and assembly of RY type hot oil pump (thermal oil pump)
1.pumpThe disassembly sequence
(1) Drain the liquid from the pump and the lubricating oil from the bearing bracket.
(2) Tighten the fixing bolts of the motor, move the motor away from the base, and remove the two halves of the coupling.
(3) Remove the pump cover connection, loosen the bearing seat bracket bolts, and extract the pump cover along with the bearing bracket and rotor part from the pump body.
(4) Unscrew the impeller nut and remove the impeller.
(5) Unscrew the pump cover and bearing seat bolts, and remove the pump cover.
(6) Unscrew the bolt on the right end bearing cover and remove the bearing cover.
(7) Remove the bearing retaining ring.
(8) Press the pump shaft out of the bearing seat.
(9) Press out the bearing on the pump shaft and remove the mechanical seal moving ring and "0" ring spring (without damage, no need to remove).
(10) Press out the static ring "0" in the bearing seat.
2. Pump assembly
The assembly sequence of the pump can be carried out in the reverse order of disassembly. When disassembling and reassembling, it is necessary to check whether the mechanical seals and various parts have failed. If there is any failure or damage, it is necessary to replace them with new spare parts. When installing, be careful not to knock them to avoid damaging the parts.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!