Hash DR6000 UV Visible spectrophotometer
Product Overview:
The DR6000 UV Visible spectrophotometer is the fourth generation spectrophotometer product launched by Hash Company in 2012. It can measure water samples in the UV and visible light regions with excellent analytical accuracy, achieving a perfect unity of reliable results and efficient measurement.
The intuitive menu navigation system and 7-inch color touch screen of DR6000 UV visible spectrophotometer enable customers to input and calibrate custom methods through a few simple steps; Support customized applications that can fully meet the needs of customers with strict precision requirements; Built in AQA with planning, management, and recording functions; Support Ethernet connection, which can quickly obtain data and perform real-time data transmission; The instrument is equipped with over 250 pre programmed methods (for measurable parameters, please refer to the "Hash Spectrophotometer and Colorimeter Measurement Parameter List" in the sample), as well as optional software application packages, including analysis of drinking water and beer.
This instrument can be widely used for laboratory water quality monitoring in industrial, municipal, environmental protection, education and research, disease control and other fields.
Features and advantages:
-
The instrument is equipped with over 250 pre programmed methods, including parameters such as TOC, heavy metals, and nutrients. The intuitive menu navigation system and 7-inch color touch screen allow users to input and calibrate their own methods through a few simple steps. There is also an optional application package that includes analysis speed scanning for drinking water, beer, etc., combined with a simple LIMS (Laboratory Information Management System).
-
DR6000 can achieve the highest analysis efficiency in the laboratory. It has data storage function, which can store 5000 sets of data and 200 user-defined programs. It can automatically recognize pre made hash barcode reagents, automatically measure 10 values at different positions, remove outliers and take the average, and display the final average value within 10 seconds. As a result, with the use of pre prepared hash reagents, the number of work steps will be greatly reduced and comparable to standard methods. The experimental process can be monitored and calibration data, batch numbers, measurement steps, and raw data can be accessed at any time.
-
Optional rotating adapter, digester, and flow pool module for continuous analysis with three USB interfaces, and Ethernet port for fast data acquisition and real-time data transmission. Can be directly connected to a printer and print experimental results
-
It has three-level password protection function, permission setting function, and timer function.
Spare parts item number | Instrument model | Chinese description | English description | detailed | order |
---|---|---|---|---|---|
A23794 | DR6000 UV Visible spectrophotometer | motor | Carousel Motor | Detailed | Inquiry car |
LZQ105 | DR6000 UV Visible spectrophotometer | Sample pool cover | Sipper flap for DR6000 | Detailed | Inquiry car |
LZV593 | DR6000 UV Visible spectrophotometer | Filter wheel belt | Tooth belt for filter changer | Detailed | Inquiry car |
LZV594 | DR6000 UV Visible spectrophotometer | Barcode unit belt | Tooth belt for barcode unit | Detailed | Inquiry car |
LZV850 | DR6000 UV Visible spectrophotometer | Barcode driven motor | Stepping drive for barcode | Detailed | Inquiry car |
LZV851 | DR6000 UV Visible spectrophotometer | lithium battery | Lithium battery (buffer) | Detailed | Inquiry car |
LZV862 | DR6000 UV Visible spectrophotometer | Camera (pre adjusted) | Camera, preadjusted | Detailed | Inquiry car |
LZV866 | DR6000 UV Visible spectrophotometer | Measurement pool detection (transparent plastic) | Light pipe round cuvette recognition | Detailed | Inquiry car |
LZV869 | DR6000 UV Visible spectrophotometer | speaker | Speaker | Detailed | Inquiry car |
LZV881 | DR6000 UV Visible spectrophotometer | USB A protective cover | protective cover for USB A interface | Detailed | Inquiry car |
LZV885 | DR6000 UV Visible spectrophotometer | Display screen (including touch) | Display and Touchscreen, DR 6000 | Detailed | Inquiry car |
LZV897 | DR6000 UV Visible spectrophotometer | Glass lens fixing bracket (measuring cell position) | Spring for glass lens DR 5000/6000 | Detailed | Inquiry car |
LZV902.99.00020 | DR6000 UV Visible spectrophotometer | Adapter A (can be used to test multiple specifications of sample bottles) | Multi-Cell Holder | Detailed | Inquiry car |
LZV906 | DR6000 UV Visible spectrophotometer | Circular adapter | Round cuvette holder | Detailed | Inquiry car |
LZV907 | DR6000 UV Visible spectrophotometer | Grating (including bracket) | Grating with holder | Detailed | Inquiry car |
LZV908 | DR6000 UV Visible spectrophotometer | filter wheel | Filter wheel with filter glasses | Detailed | Inquiry car |
LZV909 | DR6000 UV Visible spectrophotometer | Filter wheel motor | Motor filter wheel | Detailed | Inquiry car |
LZV912 | DR6000 UV Visible spectrophotometer | Sample pool cover assembly | Sliding Lid Cuvette Compartment | Detailed | Inquiry car |
LZV914 | DR6000 UV Visible spectrophotometer | Sample pool cover slide rail | Fixed Surface of Sliding Lid | Detailed | Inquiry car |
LZV915 | DR6000 UV Visible spectrophotometer | Filter cotton | Filter Pad for DR 6000 | Detailed | Inquiry car |
LZV916 | DR6000 UV Visible spectrophotometer | Top cover | Enclosure, Top | Detailed | Inquiry car |
LZV919 | DR6000 UV Visible spectrophotometer | Lower shell | Housing bottom | Detailed | Inquiry car |
LZV920 | DR6000 UV Visible spectrophotometer | back cover | Rear cover | Detailed | Inquiry car |
LZV921 | DR6000 UV Visible spectrophotometer | Logo label | Badge Logo Set | Detailed | Inquiry car |
LZV922 | DR6000 UV Visible spectrophotometer | dust cover | Dust Cover, Optics | Detailed | Inquiry car |
LZV923 | DR6000 UV Visible spectrophotometer | Camera light path conduit (solid transparent plastic tube) | Light pipe camera illumination DR 6000 | Detailed | Inquiry car |
LZV924 | DR6000 UV Visible spectrophotometer | Light source selection mirror motor | Mirror Flap Motor | Detailed | Inquiry car |
LZV925 | DR6000 UV Visible spectrophotometer | Temperature sensor | Temperature Sensor Lamp Cover | Detailed | Inquiry car |
LZV926 | DR6000 UV Visible spectrophotometer | Fan | Fan 120mm | Detailed | Inquiry car |
LZV927 | DR6000 UV Visible spectrophotometer | Fan | Fan 80mm | Detailed | Inquiry car |
LZV928 | DR6000 UV Visible spectrophotometer | Adapter | Adapter for 100 mm cell | Detailed | Inquiry car |
LZV929 | DR6000 UV Visible spectrophotometer | Sample pool room (hach) | Sample Compartment Hach | Detailed | Inquiry car |
LZV930 | DR6000 UV Visible spectrophotometer | Lamp cover screw | Lamp Cover with screw | Detailed | Inquiry car |
LZV931 | DR6000 UV Visible spectrophotometer | Fan cover | Fan Cover | Detailed | Inquiry car |
LZV932 | DR6000 UV Visible spectrophotometer | Front cover | Front cover | Detailed | Inquiry car |
LZV934 | DR6000 UV Visible spectrophotometer | Cable package | Cable set DR 6000 | Detailed | Inquiry car |
LZV945 | DR6000 UV Visible spectrophotometer | Countersunk screw | Holder for Carousel Adapter | Detailed | Inquiry car |
YAB120 | DR6000 UV Visible spectrophotometer | RFID module (not available on domestic machines) | RFID Module | Detailed | Inquiry car |
YAB124 | DR6000 UV Visible spectrophotometer | a main board | Mainboard | Detailed | Inquiry car |
YAB125 | DR6000 UV Visible spectrophotometer | Hall sensor board (adapter position recognition) | Hall sensor board | Detailed | Inquiry car |
YAB126 | DR6000 UV Visible spectrophotometer | Reference signal PCB | Reference Element Board | Detailed | Inquiry car |
YAB127 | DR6000 UV Visible spectrophotometer | Measurement signal PCB | Measurement Element Board | Detailed | Inquiry car |
YAB128 | DR6000 UV Visible spectrophotometer | Lamp board (including rear USB, Ethernet port, and lamp power supply) | Lamp Connector Board | Detailed | Inquiry car |
YAB129 | DR6000 UV Visible spectrophotometer | Grating motor (including PCB) | Grating Motor with PCB | Detailed | Inquiry car |
YAB145 | DR6000 UV Visible spectrophotometer | Switching Mode Power Supply | Switched Mode Power Supply Unit | Detailed | Inquiry car |
Item number | Applicable instrument model | parameter | Analysis method | Test frequency | range |
---|---|---|---|---|---|
2760445 | DR6000 UV Visible spectrophotometer | Comprehensive index of nutrients and organic pollutants, total organic carbon (TOC) | Acid-base indicator method | 0 | 20-700C |
2762700 | DR6000 UV Visible spectrophotometer | Organic pollutant atrazine | Immune tube method | Immune tube method | Atractylodes macrocephala |
2767245 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and total phosphorus | Dissolve molybdenum antimony resistance method | 0 | 1.0-100.0 PO43- |
2767345 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and active phosphorus | Molybdenum antimony resistance method | 0 | 1.0100.0 PO43 |
2773500 | DR6000 UV Visible spectrophotometer | Organic pollutant polychlorinated biphenyls (PCBs) | Immune tube method | 0 | Immune tube method |
44449 | DR6000 UV Visible spectrophotometer | Inorganic anionic fluoride | SPADNS method | 125 | 0.02-2.00 |
2774300 | DR6000 UV Visible spectrophotometer | Total Petroleum Hydrocarbons (TPH) in Organic Pollutant Soil | Immune tube method | 0 | Immune tube method |
2790800 | DR6000 UV Visible spectrophotometer | Disinfectant indicator trihalomethanes | THM Plus method | 0 | 10-600μg/L |
2802246 | DR6000 UV Visible spectrophotometer | Disinfectant indicator: Chloramine | Indigo method | 50 | 0.04-4.50(Cl2) |
2805145 | DR6000 UV Visible spectrophotometer | Disinfectant indicator: Chloramine | Indigo method | 0 | 0.1-10.0(Cl2) |
2813000 | DR6000 UV Visible spectrophotometer | Organic pollutant potassium grass amine | Immune tube method | 18 | Immune tube method |
2815945 | DR6000 UV Visible spectrophotometer | Comprehensive index of nutrients and organic pollutants, total organic carbon (TOC) | Acid-base indicator method | 0 | 15-150C |
TNT820 | DR6000 UV Visible spectrophotometer | Standard method for comprehensive indicators of nutrients and organic pollutants - Chemical Oxygen Demand (CODCr) | Digestion colorimetric method | 24 | 1-60mg/L COD |
103769 | DR6000 UV Visible spectrophotometer | Ferrous metal | 110 diazophenanthrene spectrophotometric method | 100 | 0.02-3.00 |
TNT826 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and total nitrogen | Persulfate oxidation method | 25 | 1-16 N |
TNT827 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and total nitrogen | Persulfate oxidation method | 25 | 5-40 N |
TNT830 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, ammonia nitrogen | Salicylic acid method | 25 | 0.015-2 NH3-N |
TNT831 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, ammonia nitrogen | Salicylic acid method | 25 | 1-12 NH3-N |
TNT832 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, ammonia nitrogen | Salicylic acid method | 25 | 2-47 NH3-N |
TNT836 | DR6000 UV Visible spectrophotometer | Comprehensive index of nutrients, organic pollutants, nitrate | Xylenol method | 25 | 5-35 NO3-N |
TNT839 | DR6000 UV Visible spectrophotometer | Comprehensive index of nutrients, organic pollutants, nitrite | Diazotization method | 25 | 0.020-0.600 NO2-N |
TNT848 | DR6000 UV Visible spectrophotometer | Metal aluminum | Chromazurol S method | 24 | 0.02-0.50 |
TNT854 | DR6000 UV Visible spectrophotometer | Hexavalent chromium metal | Diphenylcarbazide spectrophotometric method | 25 | 0.03-1.00(Cr6+) |
TNT856 | DR6000 UV Visible spectrophotometer | Metal nickel | Diketoxime method | 25 | 0.10-6.00 |
TNT864 | DR6000 UV Visible spectrophotometer | Inorganic anionic sulfate | Turbidity method | 0 | 40-150 |
179032 | DR6000 UV Visible spectrophotometer | Organic pollutant hydrazine | P-dimethylaminobenzaldehyde method | 100 | 16-500μg/L |
230149 | DR6000 UV Visible spectrophotometer | Metallic iron | Ferrozine method | 1000 | 0.009-1.400 |
246066 | DR6000 UV Visible spectrophotometer | Organic pollutant cyanuric acid | Turbidity method | 50 | 550 |
1206499 | DR6000 UV Visible spectrophotometer | Barium | Turbidity method | 100 | 1-100 |
1271099 | DR6000 UV Visible spectrophotometer | Hexavalent chromium metal | Diphenylcarbazide spectrophotometric method | 100 | 0.01-0.70(Cr6+) |
1406499 | DR6000 UV Visible spectrophotometer | Disinfectant indicator: Total residual chlorine | DPD method | 100 | 0.1-10.0(Cl2) |
1407099 | DR6000 UV Visible spectrophotometer | Inorganic anion free residual chlorine | Blush method | 100 | 0.2-14.0 |
1417099 | DR6000 UV Visible spectrophotometer | Inorganic anion boron | Blush method | 100 | 0.214.0 |
2038215 | DR6000 UV Visible spectrophotometer | Comprehensive index of organic pollutants | Rapid method (165 ℃, 20 minutes) | 150(16mm) | 15-150(mg/l) |
2038225 | DR6000 UV Visible spectrophotometer | Comprehensive index of organic pollutants | Rapid method (165 ℃, 20 minutes) | 25(16mm) | 15-150(mg/l) |
2038315 | DR6000 UV Visible spectrophotometer | Comprehensive index of organic pollutants | Rapid method (165 ℃, 20 minutes) | 150(16mm) | |
2038325 | DR6000 UV Visible spectrophotometer | Comprehensive index of organic pollutants | Rapid method (165 ℃, 20 minutes) | 25(16mm) | |
2076032 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and active phosphorus | Molybdenum antimony resistance method | 50 | 0.3-45.0 PO43 |
2105545 | DR6000 UV Visible spectrophotometer | Disinfectant indicator: free residual chlorine | DPD method | 50 | 0.09-5.00(Cl2) |
2105569 | DR6000 UV Visible spectrophotometer | Disinfectant indicator: free residual chlorine | DPD method | 100 | 0.02-2.00(Cl2) |
2105645 | DR6000 UV Visible spectrophotometer | Disinfectant indicator: Total residual chlorine | DPD method | 50 | 0.09-5.00(Cl2) |
2105669 | DR6000 UV Visible spectrophotometer | Disinfectant indicator bromine | Blush method | 100 | 0.05-4.50 |
2105769 | DR6000 UV Visible spectrophotometer | Metal total iron | FerroVer method | 100 | 0.02-3.00 |
2105869 | DR6000 UV Visible spectrophotometer | Physical and chemical indicators | Quinoline method | 100 | 0.04-5.00(Cu) |
2106069 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and active phosphorus | Ascorbic acid TNT method | 100 | 0.02-2.50 PO43- |
2106169 | DR6000 UV Visible spectrophotometer | Comprehensive index of nutrients, organic pollutants, nitrate | Cadmium reduction method | 100 | 0.3-30 NO3-N |
2107169 | DR6000 UV Visible spectrophotometer | Comprehensive index of nutrients, organic pollutants, nitrite | Diazotization method | 100 | 0.002-0.3 NO2-N |
2107569 | DR6000 UV Visible spectrophotometer | Comprehensive index of nutrients, organic pollutants, nitrite | Ferrous sulfate method | 100 | 2-150 NO2-N |
2107669 | DR6000 UV Visible spectrophotometer | Manganese reagent component | Periodate method | 100 | 0.1-20.0 |
2125825 | DR6000 UV Visible spectrophotometer | Standard method for comprehensive indicators of nutrients and organic pollutants - Chemical Oxygen Demand (CODCr) | Digestion colorimetric method | 25 | 3-150 COD |
2125925 | DR6000 UV Visible spectrophotometer | Standard method for comprehensive indicators of nutrients and organic pollutants - Chemical Oxygen Demand (CODCr) | Digestion colorimetric method | 25 | 20-1500 COD |
2141299 | DR6000 UV Visible spectrophotometer | Organic pollutants benzotriazole, methylbenzotriazole | UV method | 100 | 1-16, 1-20 |
2242000 | DR6000 UV Visible spectrophotometer | Metal aluminum | Aluminum reagent method | 100 | 0.008-0.800 |
2242201 | DR6000 UV Visible spectrophotometer | Metal cadmium | Dithiazone method | 0 | 0.7-80.0μg/L |
2242300 | DR6000 UV Visible spectrophotometer | Disinfectant indicator chlorine dioxide | Chlorophenol red method | 100 | 0.01-1.00(ClO2) |
2242500 | DR6000 UV Visible spectrophotometer | Total chromium metal | Alkaline hypobromic acid oxidation method | 100 | 0.01-0.70(Cr) |
2243500 | DR6000 UV Visible spectrophotometer | Metal nickel | Cycloheptanedione oxime method | 50 | 0.02-1.80 |
2243900 | DR6000 UV Visible spectrophotometer | Volatile phenols of organic pollutants | 4-aminoantipyrine method | 100 | 0.002-0.200 |
2244100 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and active phosphorus | Amino acid method | 100 | 0.23-30.00 PO43- |
2244201 | DR6000 UV Visible spectrophotometer | Metal | Diaminobenzidine method | 0 | 0.01-1.00 |
2244500 | DR6000 UV Visible spectrophotometer | Inorganic anionic sulfide | Methylene blue method | 100 | 0.01-0.7S |
2244600 | DR6000 UV Visible spectrophotometer | Organic pollutants such as tannic acid and lignin | Tyrosine method | 100 | 0.1-9.0 |
2244700 | DR6000 UV Visible spectrophotometer | Organic pollutant volatile acid | Esterification method | 90 | 27-2800 |
2257700 | DR6000 UV Visible spectrophotometer | Organic pollutant formaldehyde | MBTH method | 100 | 3-500μg/L |
2296600 | DR6000 UV Visible spectrophotometer | Metallic silver | colorimetry | 50 | 0.005-0.700 |
2319800 | DR6000 UV Visible spectrophotometer | Inorganic anionic chloride | Mercuric thiocyanate method | 100 | 0.1-25.0(Cl-) |
2319900 | DR6000 UV Visible spectrophotometer | Physical and chemical indicators hardness | Calcium magnesium reagent method | 100 | 0.07-4.00CaCO3 |
2375000 | DR6000 UV Visible spectrophotometer | Metallic lead | Rapid extraction method | 20 | 5-150μg/L |
2415825 | DR6000 UV Visible spectrophotometer | Standard method for comprehensive indicators of nutrients and organic pollutants - Chemical Oxygen Demand (CODCr) | Digestion colorimetric method | 25 | 0.7-40.0 COD |
2415925 | DR6000 UV Visible spectrophotometer | Standard method for comprehensive indicators of nutrients and organic pollutants - Chemical Oxygen Demand (CODCr) | Digestion colorimetric method | 25 | 200-15000 COD |
2429700 | DR6000 UV Visible spectrophotometer | Organic pollutant phosphonate | UV digestion method | 100 | 0.02-2.50 |
2429800 | DR6000 UV Visible spectrophotometer | Comprehensive index of nutrients, organic pollutants, nitrate | Cadmium reduction method | 100 | 0.01-0.50 NO3-N |
2430000 | DR6000 UV Visible spectrophotometer | Manganese metal | Periodate method | 100 | 0.2-20.0 |
2430200 | DR6000 UV Visible spectrophotometer | Inorganic Anionic Cyanide | Pyrimidine pyridine ketone method | 100 | 0.001-0.240(CN-) |
2446600 | DR6000 UV Visible spectrophotometer | Organic pollutant carbonyl trap (residual corrosion inhibitor) | Iron reduction method | 0 | 5-600μg/L |
2446801 | DR6000 UV Visible spectrophotometer | Organic pollutant anionic surfactant (detergent) | Crystal violet method | 0 | 0.002-0.275 LAS |
2449400 | DR6000 UV Visible spectrophotometer | Inorganic anionic molybdate | Ternary complex method | 100 | 0.02-3.00 |
2458200 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, ammonia nitrogen | Nessler's reagent method | 0 | 0.02-2.50 NH3-N |
2459100 | DR6000 UV Visible spectrophotometer | Potassium metal | Arsenic testing box method | 100 | 0.1-7.0 |
2459200 | DR6000 UV Visible spectrophotometer | Organic pollutant quaternary ammonium salt | Binary complex method | 100 | 0.2-5.0CTAB |
2459300 | DR6000 UV Visible spectrophotometer | Inorganic Anionic Silicon | Silicon molybdenum blue method | 100 | 0.011.60 SiO2 |
2495301 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and total Kjeldahl nitrogen | Nessler's reagent method | 250 | 1-150 |
2515025 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, dissolved oxygen | HRDO method | 25 | 0.3-15.0O2 |
2516025 | DR6000 UV Visible spectrophotometer | Disinfectant indicator ozone | Indigo method | 25 | 0.01-0.25O2 |
2517025 | DR6000 UV Visible spectrophotometer | Disinfectant indicator ozone | Indigo method | 25 | 0.01-0.25O2 |
2518025 | DR6000 UV Visible spectrophotometer | Disinfectant indicator ozone | Indigo method | 25 | 0.01-0.25O2 |
2544800 | DR6000 UV Visible spectrophotometer | Metal total iron | FerroMo method | 100 | 0.012-1.800 |
2553500 | DR6000 UV Visible spectrophotometer | Inorganic Anionic Silicon | Silicon molybdenum blue flow cell method | 100 | 3-1000μg/LSiO2 |
2563000 | DR6000 UV Visible spectrophotometer | Disinfectant indicator: Total residual chlorine | DPD Flow Pool Method | 20 | 2-500μg/L(Cl2) |
2597200 | DR6000 UV Visible spectrophotometer | Physical and chemical indicators toxicity | ToxTrak method | 0 | 0-100% inhibition |
2603100 | DR6000 UV Visible spectrophotometer | Physical and chemical indicators: total hardness | Chlorophosphonazo method | 100 | 4-1000μg/LCaCO3 |
2603300 | DR6000 UV Visible spectrophotometer | Physical and chemical indicators of copper | Porphyrin method | 100 | 2-210μg/L(Cu) |
2603700 | DR6000 UV Visible spectrophotometer | Metal aluminum | Chrome Cyanine R Method | 100 | 0.002-0.250 |
2604100 | DR6000 UV Visible spectrophotometer | Inorganic anionic molybdate | Mercaptoacetic acid method | 100 | 0.3-40.0 |
2604545 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, ammonia nitrogen | Salicylic acid method | 0 | 0.02-2.50 NH3-N |
2606945 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients and organic pollutants | Salicylic acid method | 0 | 0.4-50.0 NH3-N |
2623425 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and chemical oxygen demand (CODMn) | Digestion colorimetric method | 25 | 30-1000COD |
2651600 | DR6000 UV Visible spectrophotometer | Metal cobalt | PAN method | 100 | 0.01-2.00(Co) |
2651700 | DR6000 UV Visible spectrophotometer | Manganese metal | PAN method | 50 | 0.007-0.700 |
2658300 | DR6000 UV Visible spectrophotometer | Metallic mercury | Cold steam concentration method | 25 | 0.1-2.5μg/L |
2666900 | DR6000 UV Visible spectrophotometer | Inorganic anion boron | Blush method | 50 | 0.03-1.60 |
2668000 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, ammonia nitrogen | Salicylic acid method | 100 | 0.01-0.50 NH3-N |
2672245 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and total nitrogen | Persulfate oxidation method | 0 | 0.5-25.0 N |
2678600 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and active phosphorus | Ascorbic acid circulation pool method | 250 | 19-3000μg/L PO43- |
2714100 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and total nitrogen | Persulfate oxidation method | 0 | 10-150 N |
2742545 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and active phosphorus | Ascorbic acid method | 0 | 0.06-5.00 PO43- |
2742645 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, and total phosphorus | Ascorbic acid digestion method | 0 | 0.06-3.5 PO43- |
2742745 | DR6000 UV Visible spectrophotometer | Comprehensive indicators of nutrients, organic pollutants, acid hydrolyzable phosphorus | Ascorbic acid method | 0 | 0.07-5.0PO43- |
2760345 | DR6000 UV Visible spectrophotometer | Comprehensive index of nutrients and organic pollutants, total organic carbon (TOC) | Acid-base indicator method | 0 | 0.3-20.0C |