VIP member
HQ308 diffusion silicon flange high-temperature flat film pressure transmitter
Brief introduction: HQ-308 (formerly 2088) diffusion silicon pressure sensor product features: reverse polarity and current limiting protection; Laser
Product details
Brief introduction:
HQ-308 (formerly 2088) diffusion silicon pressure sensor product features: reverse polarity and current limiting protection; Laser resistance temperature compensation; Zero point and range can be adjusted on site; Wide range, corrosion-resistant, suitable for various media; Strong overload and anti-interference ability, stable performance.
accuracy classHQ308 diffusion silicon pressure transmitter
HQ308 Diffusion Silicon Pressure Transmitter Product Overview
The HQ308 series pressure transmitter has the characteristics of reliable operation, stable performance, easy installation and use, small size, light weight, and high cost-effectiveness, and can be widely used in various positive and negative pressure measurements.
The HQ308 series pressure transmitter uses imported diffused silicon or ceramic core as the pressure detection element, and the sensor signal is converted into a unified output signal of 0-10mA or 4-20mA through a high-performance electronic amplifier. It can replace traditional remote pressure gauges, Hall elements, and differential transmitters, and has the performance of DDZ-I and DDZ-II transmitters. It can be used in conjunction with various types of dynamic coil indicators, digital pressure gauges, electronic potentiometers, as well as with various automatic adjustment systems or computer systems. Widely used in industries such as electricity, petrochemicals, machinery, metallurgy, and various energy measurement fields
Main technical parameters of HQ308 diffusion silicon pressure transmitter
0.3 level basic error+0.3%
output characteristic
① 0~10mA output, load resistance 0~1.5KO! ② 4-20mA output, load resistance 0~6000 ③ constant current output, internal resistance greater than 10MO ④ two-wire 4-20mA output
0.5 level basic error+0.5%
Standard power supply
DC24V
Nonlinear error
0.3 level ≤+0.3% FS
Explosion proof sign
(RPT- II ): Exia I CT4-6
Level 0.5 ≤+0.5% FS
hysteresis error
≤ 0.3% FS
dead zone
≤+0.3% FS
Q308 diffusion silicon pressure transmitter measurement range
Gauge pressure: 0-5kPa~100MPa
Absolute pressure: 0-20kPa~100MPa
Sealed gauge pressure: 0-7MPa~120MPa
Negative pressure: -100kPa~700kPa
External dimensions of HQ308 diffusion silicon pressure transmitter

HQ308Diffuse silicon pressure transmittermodel selection

HQ308Diffuse silicon pressure transmitterElectrical connection



HQ308Diffuse silicon pressure transmittermodel selection

HQ308Diffuse silicon pressure transmitterElectrical connection


HQ308 diffusion silicon pressure transmitter ordering instructions
Users need to specify the model and measurement range when placing an order
Users should indicate the relevant parameters such as medium name, temperature, etc. The measured medium can coexist with the sensor and sealing ring
For more detailed usage and installation, please refer to the accompanying user manual