summary:
The handheld ultrasonic flowmeter realizes non-contact measurement of liquid flow rate. Simply install the sensor on the outer wall of the pipeline to complete the measurement of flow rate. It has the characteristics of small size, easy portability, and accurate measurement. Widely used in industries such as tap water, heating, water conservancy, metallurgy, chemical industry, machinery, energy, etc. It can be used for production monitoring, flow verification, temporary testing, flow inspection, water balance debugging, heat network balance debugging, and energy-saving monitoring. It is an essential tool for real-time flow detection.
characteristic:
- High precision measurement accuracy up to 1%
- The measurement range is wide, and different types of sensors can be selected to measure the flow rate of pipelines with diameters ranging from DN15 to DN6000
- High reliability adopts low voltage and multi pulse transmission circuit, with high measurement accuracy, significantly improved service life and reliability
- Strong anti-interference ability, using dual balanced signal differential transmission and reception circuits
- The powerful memory function automatically remembers the accumulated flow rate of the previous 512 days, the time and flow rate of the first 64 power outages, and the working status of the flowmeter in the previous 32 days.
- Long transmission distance and fast networking. RS485 supports wireless networking and is paired with GPRS module for wireless transmission
- Supporting heat measurement with temperature sensors, it can achieve measurement and measurement
- The charging power supply is equipped with a large capacity nickel hydrogen rechargeable battery, which can support continuous operation of the flowmeter for more than 12 hours. Charging with a power adapter enables uninterrupted measurement.
- Non contact measurement involves installing a magnetic ultrasonic flowmeter sensor on the outer wall of the pipeline to complete flow measurement
- Support multilingual menus that can be customized in multiple languages such as Chinese, English, Italian, etc
- The large screen LCD display can simultaneously display accumulated flow, instantaneous flow, flow rate, working status, etc.
Flow measurement composition diagram:
|
The outer wall can achieve flow measurement. No need to disconnect or break the pipe Flow, no pressure loss.
Measurement of pipeline flow from DN 15 to DN 6000.
Measurement of liquid flow rate at temperatures ranging from 30 to 160 ℃. |
Installation and fixing method:
Technical parameters:
Installation of sensors:
- After selecting the installation location of the sensor, it is necessary to determine the method of installing the sensor based on the diameter of the pipeline (V method and Z method are usually used)
- After selecting the installation method for the sensors, the remaining distance is the installation distance between the sensors, which is the value displayed in window M25 of the host. (It can be obtained by the user entering parameters such as pipe diameter, pipe wall thickness, pipe material, liquid type, etc. in the host).