HD1000The series isolator uses optical, electrical, and magnetic isolation technologies to isolate the power supply, input signals, and output signals in pairs, thereby achieving isolated signal transmission between field equipment and control systems. It is an isolation interface unit between field equipment and control room equipment; Isolation technology completely isolates input and output signals electrically, greatly improving the anti-interference and reliability of electronic systems. Currently, more and more industrial control systems and field devices are using isolated interface units to replace non isolated units in their interfaces.
HD1000The full range of isolators covers the following equipment functions: thermal resistance temperature signal transmitter, thermocouple temperature signal transmitter, millivolt signal transmitter, distributor, signal distributor, and intermediate drive relay.
performance indexmain models
·Three port isolation for input/output signals and power supply
·No need for grounding
·High isolation voltage
·Provide one in two out function
·Isolate the fault point
·High conversion accuracy
·Module serialization
·Terminal "plug and play"
· DINIndependent installation of guide rails
·High density installation
n Power supply (active selection)Working power supply:(20~35)VDCThe power supply of the control instrument connected to the isolator or the voltage that may be generated inside it shall not exceed
250VAC/DC)Maximum allowable voltageU m
:250VAC/DC
n Installation environment-20Continuous operating temperature:60(~
) ℃-40Storage temperature:0(~8
) ℃9Relative humidity:(5~
5)%
nBasic structure
17.5mm Thickness model:Weight:
make an appointment 110gExternal dimensions:114.5mm×99.0mm
×17.5mm
12.5mm Thickness model:Weight:
make an appointment 100gExternal dimensions:114.5mm×99.0mm
× |
12.5mmHD10 |
|||||||||
HD1000 |
Series active isolators |
code |
Number of channels |
PRODUCT FUNCTION |
||||||
14 |
1 |
Input signal |
output signalSwitching inputContact switch and compliance |
NAMUR |
||||||
15 |
1Standard proximity switch2Relay normally open contact or normally closed contact (customized) |
enter |
go outSwitching inputContact switch and compliance |
NAMUR |
||||||
16 |
2 |
Standard proximity switch |
Relay normally open contact or normally closed contact (customized)Switching inputContact switch and compliance |
NAMUR |
||||||
40 |
1 |
Standard proximity switch |
Relay normally open contact or normally closed contact (customized)High voltage input |
High voltage signal input, optional range, maximum(0~50)V(4~20)mA, or |
||||||
42 |
1 |
(1~5)V(Customized)Analog input, with power distribution, supports bidirectional |
HARTcommunicationpower distribution(4~20)mAperhaps |
(4~20)mACurrent source(4~20)mA(Inside)/Adjustable external power distribution mode), or |
||||||
43 |
1(1~5)V2(Customized) |
entergo outAnalog input, with power distribution, supports bidirectional |
HARTcommunicationpower distribution(4~20)mAperhaps |
(4~20)mACurrent source(4~20)mA(Inside)/Adjustable external power distribution mode), or |
||||||
44 |
2 |
(1~5)V(Customized)Analog input, with power distribution, supports bidirectional |
HARTcommunicationpower distribution(4~20)mAperhaps |
(4~20)mACurrent source(4~20)mA(Inside)/Adjustable external power distribution mode), or |
||||||
46 |
1 |
(1~5)V(Customized)Analog output, supports bidirectional operation |
HART |
communication(4~20)mA(4~20)mA, or |
||||||
49 |
2 |
(1~5)V(Customized)Analog output, supports bidirectional operation |
HART |
communication(4~20)mA(4~20)mA, or |
||||||
71 |
1 |
(1~5)V(Customized)thermocouple |
/mV |
Signal transmission outputthermocoupleR (-20~1750) |
℃optional(4~20)mA, or |
|||||
(1~5)V(Customized)J (-200~1200) |
||||||||||
℃optionalK (-200~1370) |
||||||||||
℃optionalB (600~1800) |
||||||||||
℃optionalE (-200~950) |
||||||||||
℃optionalN (-200~1300) |
||||||||||
℃optionalS (-20~1750) |
||||||||||
℃optionalT (-200~400) |
||||||||||
℃optional |
mVsignal |
|||||||||
72 |
1 |
(-75~75)mVoptionalthermal resistance |
/ |
Resistance signal transmission outputthermal resistancePt100 (-200~800) |
℃optional(4~20)mA, or |
|||||
(1~5)V(Customized)Cu50 (-50~300) |
||||||||||
℃optionalPt1000 (-50~150) |
||||||||||
℃ |
optionalResistance signal(0~2200) |
|||||||||
76 |
1Ω2optional |
entergo outthermocouple |
/mV |
Signal transmission outputthermocoupleR (-20~1750) |
℃optional(4~20)mA, or |
|||||
(1~5)V(Customized)J (-200~1200) |
||||||||||
℃optionalK (-200~1370) |
||||||||||
℃optionalB (600~1800) |
||||||||||
℃optionalE (-200~950) |
||||||||||
℃optional |
||||||||||