HANNA HANNA HI98703 portable high-precision multi range turbidity analyzer from Italy Product Introduction:
The HI98703 high-precision turbidity analyzer has an optical system with automatic adjustment function, which does not require frequent calibration. You can choose between conventional measurement, continuous measurement, or average measurement mode based on the characteristics and accuracy requirements of the measured sample. The turbidity measurement range is 0.00 to 1000NTU, and the instrument comes with a calibration group as standard. You can quickly calibrate various measurement parameters at any time. The instrument has GLP good laboratory management function, and you can check various relevant information of the last calibration, such as calibration point, calibration time, etc. User friendly interface design, displaying prompt information, providing you with step-by-step operation guidance. The instrument has excellent storage function, with 200 built-in data storage spaces and the ability to access stored data at any time. At the same time, if you choose data analysis software and data cables, you can also transfer stored data to a PC through RS232 or USB data interfaces for further data analysis.
HANNA HANNA HI98703 portable high-precision multi range turbidity analyzer from Italy. Product features:
1. Tungsten lamp light source, compliant with EPA turbidity measurement standards
2. Excellent accuracy in the field of low turbidity measurement
3. Fast Tracker TM Electronic Tag Recognition System
4. 2, 3 or 4 point turbidity calibration
5. 200 stored data and can be accessed at any time
6. USB or RS232 data interface
7. Good laboratory management function of GLP
8. Humanized and user-friendly interface, background light display screen
9. Automatic shutdown power-saving mode
HANNA HANNA HI98703 portable high-precision multi range turbidity analyzer from Italy Product parameters:
Turbidity range |
0.00 to 9.99 NTU; 10.0 to 99.9 NTU; 100 to 1000 NTU |
accuracy |
± 2% of reading+0.02 NTU |
reproducibility |
± 1% of the reading or 0.02 NTU, whichever is greater |
Measurement mode |
Ordinary measurement, continuous measurement, average measurement |
optical system |
Tungsten lamp light source, silicon photovoltaic cell |
Calibration method |
<0.1,15,100,750 NTU, 2-4 point automatic calibration |
Measurement standards |
USEPA 180.1 and US standard method 2130B |
Data Storage |
200 sets of measurement data, connected to a computer via USB and RS232 data interfaces (data cables and software need to be purchased) |
Power supply mode |
4 x 1.5V AA batteries or 12Vdc power adapter |
Usage environment |
0 to 50 ℃ (32 to 122 ° F); RH max 95% non condensing |
Dimension |
224×87×77 mm;512 g |