1Advantage
(1) TheTurb 550 / Turb 550 IR
1、 Simple operation
2、 automatic1 … 3Point Correction
3、 Automatic range switching
4、 RS232output
5、 Real Time Clock
(2) TheTurb 555 / Turb 555 IR
1Simple operation
2automatic1…5Point Correction
3Automatic range switching
4RS232output
5、 Real Time Clock
6、 Wide testing scope, from0.0001 to 10000 NTU
7、 AQAFunction, with password protection
8、 Multiple testing methods:90 Degree scattering method, ratio test,180 Transmittance method
2、 Product Introduction
(1) TheTurb 550
Adopting internationally recognized standards 90 Degree scattered light turbidity method, using tungsten lamp as the light source, in compliance with the US Environmental Protection AgencyUS EPAAccording to the standard regulations, automatic 3Point correction,RS232Output and built-in real-time clock, calibration interval can be set to prompt users when to check. Wide testing scope, from0.01 …1000 NTUAutomatically switch the range between them. The dual row display screen can simultaneously display the current test value and previous test values for easy comparison. Standard equipment: concise operation card,2 Root empty test tube,3 A second level standard solution(0.02–10.0–1000 NTU)And the test tube wiping tool.
(2) TheTurb 550 IR
sameTurb 550However, the light source is infraredLEDLamp, compliantISO 7027/DIN 27027regulations.
(3) TheTurb 555
High precision laboratory turbidity meter with a wide testing range, from0.0001 to 10000 NTUCapable of almost all application scenarios, from pure water, drinking water to wastewater. Instrument belt 4 A sensor that can not only test 90 Scattered light and 180 Transmitting light can also achieve ratio testing, improving the ability to resist stray light and chromatic interference. Testing units are optional EBC(European Beer Brewing Association), can be used in the beer industry. The instrument is equipped with backlight display, making reading convenient and simple. The testing resolution is high, and users can choose the appropriate resolution. The instrument adopts a menu based operation, which is very simple to operate. In addition, this instrument has unique featuresAQAFunction can ensure testing accuracy and stability, for example, users can set calibration intervals and schedule calibration. Complete supply, including all accessories such as standard solution and blank colorimetric tube.
(4) TheTurb 555 IR
sameTurb 555However, the light source is infraredLEDLamp, compliantISO 7027/DIN 27027regulations.
3、 Technical parameters
(1) TheTurb 550
1、 Testing principle:90 Degree scattered light turbidity method
2、 Light source: tungsten lamp
3、 Test range:0 … 1000 NTUAutomatically switch range
4、 resolving power:0.00 … 9.99 NTU 0.01 NTU
10.0 … 99.9 NTU 0.1 NTU
100 … 1000 NTU 1 NTU
5、 Accuracy:±2%Current testing or±0.01 NTU
6、 Reproducibility:<±1%Or±0.01 NTU
7、 Correction: Automatic1… 3Point Correction
8、 Reaction time:<3 second
9、 Display screen: Dual row display screen, capable of displaying special characters
10Test tube:28×70 mm
11Sample volume:25 ml
12Interface:RS232
13Clock/Calendar: Built in real-time clock
14、GLPFunction: Prompt when to check
15Size:250×290×110 mm(B×D×H)
16Working temperature:10 … 40℃
17Power supply: Transformer,100-240VAC±10%/47-63 Hz
18Certification:CE,UL,CUL,TUV/GS
(2) TheTurb 550 IR
1、 Testing principle:90 Degree scattered light turbidity method
2、 Light source: infraredLEDlamp
3、 Test range:0 … 1000 NTUAutomatically switch range
4、 resolving power:0.00 … 9.99 NTU 0.01 NTU
10.0 … 99.9 NTU 0.1 NTU
100 … 1000 NTU 1 NTU
5、 Accuracy:±2%Current testing or±0.01 NTU
6、 Reproducibility:<±1%Or±0.01 NTU
7、 Correction: Automatic1… 3Point Correction
8、 Reaction time:<3 second
9、 Display screen: Dual row display screen, capable of displaying special characters
10Test tube:28×70 mm
11Sample volume:25 ml
12Interface:RS232
13Clock/Calendar: Built in real-time clock
14、GLPFunction: Prompt when to check
15Size:250×290×110 mm(B×D×H)
16Working temperature:10 … 40℃
17Power supply: Transformer,100-240VAC±10%/47-63 Hz
18Certification:CE,UL,CUL,TUV/GS
(3) TheTurb 555
1、 Testing principle:90 Degree scattered light turbidity method, ratio testing method
2、 Light source: tungsten lamp
3、 Test range:0 … 10000 NTU,0 … 2450 EBC,0 … 67000 FAU
4、 resolving power:0.0001,0.001,0.01,0.1 NTU, related to the range
5、 Accuracy:±2%Current testing or±0.01 NTU(0 … 1000 NTU)
±5%Current testing(1000 … 4000 NTU)
±10%Current testing or(4000 … 10000 NTU)
6、 Reproducibility:<±1%Or±0.01 NTUColorimetric tube28×70 mm
7、 Correction: Automatic1… 5Point Correction
8、 Sample volume:25 ml
9、 Reaction time:<6 second
10Interface:RS232, bidirectional
11Display screen: Dual row display screen, capable of displaying special characters, backlit
12Clock/Calendar: Built in real-time clock
13Working temperature:0 … 50℃
14Certification:CE,UL,CUL,TUV/GS
15、AQAFunction: The calibration interval is adjustable, and a calibration record is generated after calibration is completed. The settings and calibration are password protected, and the data transmission interval is adjustable
16Size:250×290×110 mm(B×D×H)
17Power supply: Transformer,100-240VAC ±10%/47-63 Hz
(4) TheTurb 555 IR
1、 Testing principle:90 Degree scattered light turbidity method, ratio testing method,180 Transmittance turbidity method
2、 Light source: infraredLEDlamp
3、 Test range:0 … 10000 NTU,0 … 10000 FNU,0 … 10000 FAU
4、 resolving power:0.0001 0.001,0.01,0.1 NTU, related to the range
5、 Accuracy:±2%Current testing or±0.01 NTU(0 … 1000 NTU)
±5%Current testing(1000 … 4000 NTU)
±10%Current testing or(4000 … 10000 NTU)
6、 Reproducibility:<±1%Or±0.01 NTUColorimetric tube28×70 mm
7、 Correction: Automatic1… 5Point Correction
8、 Sample volume:25 ml
9、 Reaction time:<6 second
10Interface:RS232, bidirectional
11Display screen: Dual row display screen, capable of displaying special characters, backlit
12Clock/Calendar: Built in real-time clock
13Working temperature:0 … 50℃
14Certification:CE,UL,CUL,TUV/GS
15、AQAFunction: The calibration interval is adjustable, and a calibration record is generated after calibration is completed. The settings and calibration are password protected, and the data transmission interval is adjustable
16Size:250×290×110 mm(B×D×H)
17Power supply: Transformer,100-240VAC±10%/47-63 Hz