Product Introduction
BSA series quasi micro balance, analytical balance, precision balance
The BT and BSA series electronic scales are uniquely designed to effectively and reliably perform daily laboratory weighing work. And it is precisely because of its powerful technology and clear operations and functions that it stands out from the crowd
More functions are centralized in high-resolution applications: 1mg~620g and 10mg~6200g
Low temperature LCD display with contrast light. Even under imperfect environmental conditions, reliable weighing results can always be obtained
Adopting a unique Monolith sensor with automatic processing to ensure long-term high-precision results and minimize the impact of temperature drift
The novel shell polishing technology of BSA-CW makes it more resistant to solvent corrosion and turbidity
A simple and easy to understand control panel, a well distributed keyboard, and clear and easy to read display readings can perfectly and effectively adapt to your laboratory work
Technology:
● Front mounted level
Anti static coating glass windproof cover can effectively shield the interference of external static charges
Five sided glass windshield with clear visibility
● Super parallel bar single sensor
40MHz high-speed microprocessor MC1, with faster measurement results
Latest SMT technology, higher circuit integration
● Built in RS232 interface, compliant with GLP standards
● Lower hook, suitable for large volume weighing
● Automatic calibration system
Function:
● Density direct reading
Left and right leather removal keys to meet different usage habits
The CW model comes standard with built-in calibration weights and fully automatic calibration
● Level 4 earthquake resistance
● Calculate factors
● Overload protection
● Fully automatic fault diagnosis
● Dynamic temperature compensation
Application: Counting, animal weighing, percentage weighing, net weight summation, unit conversion, total, calculation (multiplication, division)
| model | range(g) | readability | Pan size | Repeatability | linear | Calibration method |
| (mg) | (mm) | (≤+mg) | (≤+mg) | |||
| BSA124S | 120 | 0.1 | 90 | 0.1 | 0.2 | school other than one's own |
| BSA124S-CW | 120 | 0.1 | 90 | 0.1 | 0.2 | Internal calibration |
| BSA224S | 220 | 0.1 | 90 | 0.1 | 0.2 | school other than one's own |
| BSA224S-CW | 220 | 0.1 | 90 | 0.1 | 0.2 | Internal school |
| BSA223S | 220 | 1 | 115 | 1 | 2 | school other than one's own |
| BSA223S-CW | 220 | 1 | 115 | 1 | 2 | Internal calibration |
| BSA323S | 320 | 1 | 115 | 1 | 2 | school other than one's own |
| BSA323S-CW | 320 | 1 | 115 | 1 | 2 | Internal school |
| BSA423S | 420 | 1 | 115 | 1 | 2 | school other than one's own |
| BSA423S-CW | 420 | 1 | 115 | 1 | 2 | Internal calibration |
| BSA623S | 620 | 1 | 115 | 1 | 2 | school other than one's own |
| BSA623S-CW | 620 | 1 | 115 | 1 | 2 | Internal calibration |
| BSA822 | 820 | 10 | 150 | 20 | 30 | school other than one's own |
| BSA822-CW | 820 | 10 | 150 | 20 | 30 | Internal school |
| BSA2202S | 2200 | 10 | 180×180 | 10 | 20 | school other than one's own |
| BSA2202S-CW | 2200 | 10 | 180×180 | 10 | 20 | Internal calibration |
| BSA3202S | 3200 | 10 | 180×180 | 10 | 20 | school other than one's own |
| BSA3202S-CW | 3200 | 10 | 180×180 | 10 | 20 | Internal calibration |
| BSA4202S | 4200 | 10 | 180×180 | 10 | 20 | school other than one's own |
| BSA4202S-CW | 4200 | 10 | 180×180 | 10 | 20 | Internal school |
| BSA6202S | 6200 | 10 | 180×180 | 10 | 20 | school other than one's own |
| BSA6202S-CW | 6200 | 10 | 180×180 | 10 | 20 | Internal calibration |
| BSA2201 | 2200 | 100 | 180×180 | 100 | 100 | school other than one's own |
| BSA2201-CW | 2200 | 100 | 180×180 | 100 | 100 | Internal school |
| BSA5201 | 5200 | 100 | 180×180 | 100 | 100 | school other than one's own |
| BSA5201-CW | 5200 | 100 | 180×180 | 100 | 100 | Internal calibration |
| BSA8201 | 8200 | 100 | 180×180 | 100 | 100 | school other than one's own |
| BSA8201-CW | 8200 | 100 | 180×180 | 100 |