German E+H high-temperature resistant flowmeter P500 4-channel split electromagnetic flowmeter
German E+H Proline Promag P 500 electromagnetic flowmeter with the highest temperature resistance level, paired with a split type transmitter with up to 4 inputs/outputs
The German E+H Proline Promag P 500 electromagnetic flowmeter sensor is specifically designed for measuring high-temperature and corrosive media in chemical and process applications. Paired with innovative split type transmitters, the Promag P 500 maintains flexibility in installation and maximum operational safety even under harsh operating conditions. Heartbeat Technology ensures compliance at all times and guarantees process safety.
advantage
Widely applicable: Multiple welding component materials to choose from
Energy saving flow measurement: No throttling components to ensure no pressure loss
Maintenance free: No movable parts
Complete viewing of process information and diagnostic information: providing multiple user-defined input/output combination methods and fieldbus
Reduce complexity and diversity: User defined input/output functionality
Comes with verification function: Built in Heartbeat Technology
Application field
The bidirectional measurement principle is not affected by pressure, density, temperature, and viscosity
Special flowmeter for measuring high temperature and corrosive media in chemical and process applications
Instrument features
Nominal caliber: Max. DN 600 (24 ")
All universal explosion-proof (Ex) certifications
PTFE or PFA lining
Split type instrument with up to 4 inputs/outputs
Backlight display, touch key control, and WLAN access
Sensors and transmitters are connected through standard cables
Features and specifications
|
Measuring principle |
electromagnetic |
|
Product Title |
High temperature flowmeter, split type instrument with up to 4 input/output channels. A specialized flowmeter used for measuring high-temperature and corrosive media in chemical and process applications. |
|
Sensor characteristics |
Widely applicable: providing various materials for liquid receiving components. Energy saving flow measurement: There are no other devices inside the pipeline and no pressure loss. Maintenance free: No moving parts. Nominal caliber: zdDN 600 (24 "). All universal explosion-proof certifications. |
|
Characteristics of transmitter |
Provide complete process and diagnostic information: multiple user customizable I/O interfaces and fieldbuses. Reduce complexity and diversity: Allow users to customize input/output functions. Self verification: Heartbeat Technology. Split type instrument with up to 4 input/output channels. Backlight display, touch key operation, and WLAN access. |
|
Nominal caliber range |
DN 15...600 (½...24") |
|
Material of liquid receiving components |
Inner lining: PTFE |
|
Electrode: 1.4435 (316L), Alloy C22, 2.4602 (UNS N06022) alloy, tantalum, platinum |
|
|
Titanium, duplex 1.4462 (UNS S31803) |
|
|
Measure variables |
Volume flow rate, conductivity, mass flow rate |
|
Zd measurement error |
Volume flow rate (standard): ± 0.5% O.R. ± 1 mm/s (0.04 in/s) |
|
Volume flow rate (optional): ± 0.2% O.R. ± 2 mm/s (0.08 in/s) |
|
|
measurement range |
4 dm3...9600 m3/h (1...44 000 gal/min) |
|
Zd process pressure |
PN 40、Cl. 300、20K |
|
Medium temperature range |
PFA lining: -20...+150 ° C (-4...+302 ° F) |
|
High temperature PFA lining: -20...+180 ° C (-4...+356 ° F) |
|
|
PTFE lining: -40...+130 ° C (-40...+266 ° F) |
|
|
Environmental temperature range |
Carbon steel flange: -10...+60 ° C (+14...+140 ° F) |
|
Stainless steel flange: -40...+60 ° C (-40...+140 ° F) |
|
|
Material of sensor housing |
DN 15... 300 (189... 12 "): Aluminum alloy AlSi10Mg coating |
|
DN 350... 600 (14... 24 "): Carbon steel with protective paint coating |
|
|
Sensor junction box (standard): Aluminum alloy AlSi10Mg coating |
|
|
Sensor junction box (optional): 1.4409 CF3M, similar to 316L |
|
|
Material of transmitter housing |
Aluminum alloy AlSi10Mg coating; 1.4409 (CF3M), similar to 316L; polycarbonate |
|
Protection level |
Split type sensor (standard): IP66/67, Type 4X |
|
Split type sensor (optional): IP69. Split type transmitter: IP66/67, Type 4X |
|
|
Display/Operation |
4-line backlit display with touch control (operation from outside) |
|
Configuration via local display and operating tools possible |
|
|
output |
4-channel output: |
|
4... 20 mA HART (active/passive) |
|
|
4...20 mA WirelessHART |
|
|
4... 20 mA (active/passive) |
|
|
Pulse/frequency/switch output (active/passive) |
|
|
Dual pulse output (active/passive) |
|
|
relay output |
|
|
input |
Status input 4... 20 mA input |
|
digital communication |
HART、PROFIBUS PA、FOUNDATION Fieldbus、Modbus RS485、Profinet、Ethernet/IP、OPC-UA |
|
power supply |
24 VDC |
|
100...230 VAC |
|
|
100... 230 VAC/24 VDC (non hazardous area) |
|
|
Explosion-proof certification |
ATEX、IECEx、cCSAus、NEPSI、INMETRO、EAC |
|
Product safety |
CE certification, C-tick certification, EAC certification |
|
Functional safety |
Functional safety follows the IEC 61508 standard and is allowed to be used in safety applications specified in the IEC 61511 standard |
|
Metrological certification and certificates |
Perform calibration on the certification calibration device (compliant with ISO/IEC 17025 standard) |
|
Heartbeat Technology meets the traceability verification requirements of ISO 9001:2008 standard section 7.6a (T ü V certification) |
|
|
Pressure certification and certification |
PED、CRN |
|
Material Certificate |
3.1 Material Certificates |
|
Sanitary certification and certification |
ACS、NSF 61 |