GC3900PlusA gas chromatograph
The GC3900PlusA gas chromatograph is developed based on bus technology platform, upgrading and replacing the 5.7-inch LCD vertical display interface.
Product details

Product Features


This machine adopts a 5.7-inch LCD vertical display with a large Chinese screen, providing clear and intuitive images. 10 temperature control values (column box 1, 2, injector) can be displayed simultaneously on the same interface

1, 2, 3, temperature set values and actual values for detectors 1, 2, 3, auxiliary 1, 2, etc., and reserved areas for fault alarm positions, time display areas, event areas, etc.

It can display the temperature, time, events, range rise, stopwatch, extreme temperature protection values of the instrument, and add status indicator lights, fault alarm lights, etc. on a universal basis

Integrating culture and convenience.

Having core temperature control development technology, PID temperature control system, utilizing the characteristics of bus development technology, adopting control chip, dual over temperature protection of temperature control software and hardware, enabling temperature control

The system runs for a long time, is reliable and durable


Technical parameters


Pressure protection method: The carrier gas has pressure protection function. When the gas pressure is below 0.1mpa, the instrument automatically cuts off the power supply, effectively protecting the safety of chromatographic column use

Display mode: 320x240 Chinese vertical LCD display

Temperature control area: 7-way temperature control

Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃

Temperature control range: room temperature ± 8 ℃ -450 ℃, with increments of 1 ℃

Program heating: 16 stage program heating, heating rate 0.1-40 ℃/min, increments of 0.1 ℃, initial and termination time range: 0-6000min, increments of 1min

Extreme temperature: maximum protection value 450 ℃

外部事件:8通道外部事件

Power supply: 220V 50HZ 2000W


Detector indicators


Hydrogen flame ionization detector (FID):

Quality based detector

Suitable for trace analysis of organic compounds

Ignition method: automatic ignition

Detection limit: Mt ≤ 5 × 10-12g/s (n-Hexadecane-Isooctane Solution)

Noise: ≤ × 10-14A

Drift: ≤ 1 × 10-13A/30min

Linear range: ≥ 106


Thermal conductivity detector (TCD):

Concentration type detector

Constant analysis applicable to organic and inorganic gases

Sensitivity: S ≥ 3500mV • ml/mg (conventional)5000mv • ml/mg (highly sensitive) (benzene toluene solution)

Noise: ≤ 0.01mv

Baseline drift: ≤ 0.03mV/30min

Linear range: ≥ 104


Electron Capture Detector (ECD):

Radioactive ionization detector

Suitable for trace analysis of compounds containing heteroatoms such as N, O, and S

放射性同位素: 63NiActivity:370MBq(10mCi)

Detection limit: ≤ 1 × 10-14g/s

Noise: ≤ 0.03mv

Baseline drift: ≤ 0.2mv/30min

Linear range: ≥ 103


Flame photometric detector (FPD):

Quality based detector

Suitable for trace analysis of sulfur-containing and phosphorus containing compounds

Detection limit: (S) ≤ 5 × 10-11g/s ,(P)≤1×10-12g/s

Noise: ≤ 0.03mv

Baseline drift: ≤ 0.2mv/30min

Linear range: ≥ 103(S),102(P)


Nitrogen phosphorus detector (NPD):

Quality based detector

Suitable for trace analysis of nitrogen-containing and phosphorus containing compounds

Detection limit: (N) ≤ 5 × 10-12g/s ,(P)≤1×10-12g/s

Noise: ≤ 0.03mv

Baseline drift: ≤ 0.2mv/30min

Linear range: ≥ 103(N),102(P)