The low nitrogen through flow boiler is a new type of through flow steam boiler produced by introducing through flow technology from Henan Province's four-way boiler. Each low nitrogen through flow boiler is factory installed after complete machine debugging.
The low nitrogen through flow boiler consists of the boiler body (consisting of an upper header, a lower header, and water pipes), a steam water separator, a water pump, a combustion engine, and other components. Through the precise calculation of our professional engineers, while ensuring the high output of the boiler, we have greatly reduced the footprint of the boiler, saving valuable space and investment for users.
The low nitrogen through flow steam boiler only takes 2-4 minutes from start-up to steam output, and only 20 minutes from cold operation to full load. It is suitable for frequent start-up conditions and can provide steam to users quickly and timely. Steam separation is achieved by using an internal steam water separator in the drum, ensuring the dryness of the steam.
The low nitrogen through flow steam boiler belongs to a small quick installation boiler with slight operating vibration. Due to its small volume space, the damage to the main body will not cause other significant degrees of damage. It is equipped with various control and protection devices such as pressure and water level, as well as over smoke temperature protection, which has higher safety performance and no special requirements for the foundation.

Performance advantages

1. The boiler has a compact structure, beautiful appearance, and small footprint;

2. Fully automatic control, capable of unmanned operation;

3. The boiler has a small water volume, fast start-up, and good load regulation performance;

4. The unique noise reduction design ensures that the entire equipment operates with extremely low noise levels;

5. The boiler has high thermal efficiency and good environmental performance;

6. Steam is rapidly generated within 1-3 minutes due to the low water capacity and energy storage, resulting in significant changes in boiler pressure with load. This requires a reliable and responsive combustion automatic control device and water supply device;

7. Strict control of manufacturing quality is required, and a rigorous quality management system must be implemented to ensure that the manufacturing plant produces qualified high-quality products. At the same time, it has high requirements for water quality, and strict control of water quality standards should be implemented to ensure its service life;

8. The steel consumption is small, and the ratio of steel consumption to unit steam production for a tubular boiler is 1.1:1 (i.e. 1.1 tons of steel/ton of steam), while for a regular coal-fired boiler it is about 4-6 tons of steel/ton.

Technical Parameter

model LSS0.1-0.7-Q LSS0.3-0.7-Q LSS0.5-0.7-Q LSS0.75-1.0-Q
Rated evaporation capacity (Kg/h) 100 300 500 750
Work pressure (MPa) 0.7 0.7 0.7 1.0
Heating surface area of boiler (㎡) 2.8 5.7 8.21 10.77
Boiler capacity (L) 52 134 190 206
Boiler thermal efficiency (%) 92—98 92—98 92—98 92—98
Energy saving device (L) - 5.4 6.6 7.8
Fuel consumption (Nm ³/h) 7.8 22.6-21.8 37.7-36.3 56.5-54.4
Total power consumption rate of boiler (kw) 1.0 1.35 2.45 3.2
Gas inlet diameter (mm) 20 25 40 40
Inlet diameter of water supply (mm) 15 20 25 25
Steam outlet pipe diameter (mm) 20 25 32 40
Discharge diameter (mm) 25 25 25 25
Diameter of safety valve (mm) 20 20 25 25
Automatic discharge pipe diameter (mm) - - - -
Boiler weight (Kg) 366 900 1320 1630

Boiler size

Dimensions

(mm)

1020

711

1550

1500

1150

1900

1750

1250

2300

1900

1120

2230

model LSS1-1.0-Q LSS2-1.0-Q LSS3-1.0-Q LSS4-1.0-Q
Rated evaporation capacity (Kg/h) 1000 2000 3000 4000
Work pressure (Kgf/㎡) 1.0 1.0 1.0 1.0
Heating surface area of boiler (㎡) 12.58 15.86 21.84 31.3
Boiler capacity (L) 256 490 610 800
Boiler thermal efficiency (%) 92—98 92—98 92—98 92—98
Energy saving device (L) 9 11.5 35 45
Fuel consumption (Nm ³/h) 75.3-72.6 150.7-145.1 226.1-217.7 290.2-301.4
Total power consumption rate of boiler (kw) 3.9 11.4 19.3 22.8
Gas inlet diameter (mm) 40 50 65 65
Inlet diameter of water supply (mm) 25 40 40 40
Steam outlet pipe diameter (mm) 50 65 80 100
Discharge diameter (mm) 25 25 25 25
Diameter of safety valve (mm) 32 25-32 40 40
Automatic discharge pipe diameter (mm) 10 10 15 15
Boiler weight (Kg) 2050 2990 3345 3985

Boiler size

Dimensions

(mm)

2000

2200

2500

2200

2200

2500

2400

2370

2600

2400

2370

3350

remarks:
1. All the above values are calculated based on the low calorific value of natural gas (LNG) at 8400kcal/Nm ³, city gas (CG) at 4000kcal/Nm ³, coke oven gas at 4200kcal/Nm ³, diesel at 10200kcal/kg, and methanol at 4650kcal/kg.
2. According to user requirements, our company can provide other special models of boilers.