JK50-C3H6O3 Fixed Dimethyl Carbonate Detector Description:

The JK50-C3H6O3 fixed dimethyl carbonate detector is used for 24-hour continuous online monitoring of dimethyl carbonate concentration and temperature and humidity measurement on site. It displays concentration and over limit sound and light alarms on site, and remote data transmission. JK50 adopts a 2.5-inch clear color screen to display concentration in real time. According to different detection gases, it selects the best electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoionization principle gas sensors in the industry, as well as Swiss precision capacitive digital temperature and humidity sensors. JK50's advanced circuit design and mature core algorithm processing have obtained multiple software works and appearance, thus giving birth to the new generation of multifunctional fixed dimethyl carbonate detection alarm in the industry. JK50 can detect gas concentration in pipelines, confined spaces, and atmospheric environments, as well as detect gas leaks and purity of single concentration gases. The sturdy and durable explosion-proof shell and fluorocarbon paint surface treatment process are suitable for various hazardous areas and corrosive environments with strong acids and alkalis. They are wear-resistant and will not fade or peel off the paint within 10 years.

JK50-C3H6O3 fixed dimethyl carbonate detector features:

● Intrinsic safety circuit design, explosion-proof certification, secondary lightning protection and anti-static, lightning protection and anti-static capabilities exceeding standards, and resistance to strong pulse surge current impact. Reliability and stability. Anti reverse connection design, any form of reverse connection will not damage the instrument

Compliant with EMI and EMC standards, passed standard testing and CMC measuring instrument license certification.

Execution standard: GB15322.1-2003

GB 3836.1—2010Electrical equipment for explosive gas environments General requirements

GB 3836.2—2010Electrical equipment for explosive gas environments Explosion proof typed

GB 3836.4—2010Electrical equipment for explosive gas environments Essence**type“i”

Standard bus RS485 (RTU) and 4-20mA standard signal are simultaneously output, with 3 sets of relay switch output and on-site sound and light alarm (optional). Optional frequency output of 200-1000Hz, Hart protocol signal, 1-5V output, wireless transmission (2-5 kilometers or unlimited distance).

Wired or wireless remote real-time monitoring is available. The data can be uploaded to the mobile phone or transmitted to the environmental protection bureau, other monitoring centers, monitoring equipment, and monitoring computers through the LAN and Internet. The on-site concentration can be monitored in real time through free upper computer software or gas alarm controller.

Compatible with various secondary meters, data acquisition modules, PLC, DCS systems, it can directly drive electromagnetic valves, fans, alarms and other equipment, and can also drive high-power equipment by driving intermediate relays. The optional MIC2000 controller can monitor 1000 detectors simultaneously.

● Large capacity data storage function, which can record real-time concentration values, temperature and humidity, or only record alarm values and time.

Supports local storage or SD card storage. The standard capacity for local storage is 100000 records, and larger capacity should be specified when ordering.

The storage capacity of SD card can be customized. Through free upper computer software for data export and analysis, it supports viewing or deleting data on the local machine. It can be set to automatically overwrite or not overwrite data when the capacity is insufficient, and the recording function will automatically stop.

Equipped with an infrared remote control, it can achieve cover free operation in dangerous situations, such as modifying alarm points, concentration calibration, zero calibration, noise reduction, factory reset, entering menus, viewing records, 4mA output, 20mA output (this function is required for calibrating other acquisition devices).

The interface is selectable in both Chinese and English, with a default Chinese interface that supports free switching of gas concentration units. Conventional gases do not require input of molecular weight, while special gases automatically calculate and switch when molecular weight is input. Units can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/L

The 2.5-inch clear color screen (LCM) displays real-time concentration, time, temperature, humidity, storage status, and other information, and can simultaneously detect 1-6 gas concentrations and temperature and humidity. The menu interface uses clear simulation icons to display the function names of each menu, and provides concise Chinese or English operation prompts.

Three display modes can be switched: displaying multiple gas concentrations simultaneously, large font cyclic display of single channel gas concentration, real-time curve, automatic or manual cyclic switching between channels, setting whether to display large values, small values, gas names, and viewing historical curve graphs.

● Automatic zero tracking to prevent drift, temperature compensation, multiple calibrations, able to simultaneously comply with standards and local and provincial metrology bureau standards in various regions

The data recovery function and automatic identification and prevention of concentration calibration errors can avoid * * caused by improper operation.

Can record calibration logs, maintenance logs, troubleshooting strategies, sensor lifespan expiration reminders, and next concentration calibration time remindersFunction.

JK50-C3H6O3 fixed dimethyl carbonate detector parameters:

Gas detection:Dimethyl carbonate, optional: multiple can be detected simultaneously4-6 gas concentrations and temperature and humidity

Detection range:0~1, 10, 100, 1000, 2000, 10000, 20000ppm optional, other ranges can be customized

divideResolution:0.01ppm or 0.001ppm (0-10ppm); 0.01ppm (0-100ppm), 0.1ppm (0-1000ppm), 1ppm (above 0-1000ppm)

Detection principle:Electrochemical, infrared, catalytic combustionPID、 Semiconductors, optical waveguides, MOSFETs, etc. (depending on the specific gas) can also be customized according to gas type, range, on-site environment, and user needs

Sensor lifespan:PID 2 years, electrochemical principle 3 years, oxygen 2 years or 6 years, infrared 5-10 years, catalytic combustion 3 years, thermal conductivity 5 years

Temperature detection:-40 ℃~+120 ℃ (optional), humidity detection: 0~RH (optional), resolution: temperature 0.1 ℃, humidity: 1% RH

Detection accuracy:≤± 2% F.S (2% over the full range), temperature 0.5 ℃, humidity 3% RH, higher accuracy can be customized

Detection method:Fixed installation, online detection, diffusion measurement, pipeline type(M45X1.5 external thread), flow-through, pump

Suction is optional.

Installation method:Pipeline and wall mounted. The working pressure of pipeline type is atmospheric pressure± 30%, if it exceeds the range, it needs to be depressurized
Response time:T90 ≤ 10 seconds

Recovery time:≤ 10 seconds
Output signal:Bus systemRS485(RTU)、 Three (four) wire system 4-20mA, optional 0-20mA, 1-5V, 0-5V, 0-5V

10V、 Wireless transmission

Alarm method:On site sound and light alarm (optional), default1 channel, optional 3 passive contact (dry node) outputs, 3 alarms,

Alarm points can be set
Work environment:-40℃~+70℃

Sample gas temperature:-40 ℃~+70 ℃ (conventional),Optional:-40 ℃~+400 ℃, -40 ℃~+800 ℃ (1300 ℃)
Relative humidity:≤ 10-95% RH (conventional) in non condensing situations,Optional:10-99% RH for temperature and humidity applications, when ordering

Please note that a preprocessing system is required
Working voltage:12~30V (DC, standard power supply for a single device is 24V, 1A or greater DC switching power supply)

Power reference:A 24V, 2.1A switching power supply can drive 40 toxic gas detectors or 15 combustible and infrared gas detectors

Physical examination instrument.
Explosion proof form:Explosion proof typeExdⅡCT6
Connecting cables:Select a three core shielded cable for 4-20mA and a four core cable for RS485. When the distance exceeds 1000 meters, the single wire diameter should be ≥ 1.5mm

Cover layer grounding

Electrical interface:3/4NPT, Optional M20X1.5 internal thread, 1/2NPT
Protection, etc.:IP66 waterproof splash and short-term rain exposure. For long-term rain exposure, a rain cover should be selected or a shell without display should be chosen or ordered

Please indicate when shipping.
External dimensions:210×170×85mm
weightQuantity:1.8Kg

Optional accessories:Wall mounting brackets, mounting brackets fixed on pipelines (four and six branch pipes)Installation of DN50 flange pipeline or stainless steel threaded welding socket (pipe size should be specified, such as DN50, DN15...), room temperature and humidity pretreatment system, temperature and humidity pretreatment system, temperature and humidity dust pretreatment system, pressure reducing valve, flow meter, temperature and humidity measurement, large capacity SD storage card, rain cover, 24VDC or 220AC sampling pump (sampling distance of 10 meters), vacuum pump (sampling distance greater than 40 meters), 24V switch power supply.

Accessories required for computer monitoring:Free PC softwareRS485/RS232 converter, laptop without RS232 interface

Brain still needsUSB/RS232 conversion cable, TCP/IP converter is required for network transmission

Application scenarios:All occasions that require fixed installation and online detection of gas concentration, such as petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment, etc

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!