Shanghai Keyou Automation Technology Co., Ltd
Home>Products>FU50 Ultrasonic Flow Meter (Ultrasonic Water Meter)
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    1st Floor, Building 2, No. 89 Huguang East Road, Meilian Industrial Park, Minhang District, Shanghai (201108)
Contact Now
FU50 Ultrasonic Flow Meter (Ultrasonic Water Meter)
Principle and structure: When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time. The ch
Product details

FU50超声波流量计(超声波水表)FU50超声波流量计(超声波水表)

Principle, structure

When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, and the change in propagation time is proportional to the flow velocity of the liquid, which follows the following expression:

FU50超声波流量计公式
FU50超声波流量计原理图
of which

θ is the angle between the sound beam and the direction of liquid flow

M is the number of straight line propagation times of the sound beam in the liquid

D is the inner diameter of the pipeline

TUP is the propagation time of the sound beam in the positive direction

Tdown is the propagation time of the sound beam in the opposite direction

△T=Tup-Tdown

characteristic

Dual channel high-precision design with DN50 caliber and above diversion layer

● Protection level IP68

● Built in quantitative controller and time-sharing accumulator

Automatically start the controller at the set time to achieve automatic timed and quantitative water supply or irrigation.

Gradual rate has been achieved by accumulating traffic in a set time period.

● Thermal measurement

Equipped with dual PT1000 temperature measurement function, it can achieve heat metering and is suitable for the air conditioning and refrigeration industry.

Ultrasonic measurement, no rotation, no worn parts

Long term guarantee of measurement accuracy and high overall reliability.

Suitable for various water qualities, including those containing gravel and weeds.

Technical Parameter

Measure fluid Full pipes of water, sewage, seawater (other liquids need to be customized)
Fluid temperature 0-30°C(0-160℃)
work environment Temperature: -10-45 ℃; Humidity ≤ 100% (RH)
Enduring pressure 1.6Mpa (2.5Mpa optional)
Upstream fluency sensitivity level U3
Downstream fluency sensitivity level D0
Electromagnetic compatibility level E2 level
communication interface RS485/M-BUS/Infrared
output signal Two isolated OCT or TTL pulse outputs/one two-wire 4-20mA
power supply Built in lithium battery (3.6V, 19Ah)/external DC8-36V DC power supply/two-wire 4-20mA power supply
protection grade IP68 capable of working up to 2 meters underwater
Local display Dual row display includes 9-digit cumulative quantity, 4-digit instantaneous flow, as well as various status prompts and units
Data Storage Using EEPROM/FLASH to store parameters, automatically record the cumulative traffic of the previous 128 months and 512 days
Flow measurement cycle Measurement status: once per second; Verification status: 4 times/second
power consumption The battery can be used continuously for more than 10 years
Liquid receiving material DN15-DN40 brass (stainless steel)
DN50-DN150 ductile iron (stainless steel)
DN200-DN300 carbon steel (stainless steel)

Display and operation

58 × 22mm LCD display

Display instantaneous flow, cumulative flow, time, and various statuses on the same screen

Touch button

Touch the glass with your fingers to complete the operation

Support forward and reverse flow measurement

Can measure instantaneous flow and cumulative flow separately in both forward and reverse directions

Multiple measurement units can be set

Accumulated traffic: m³、ft3、GAL、L

Instantaneous flow rate: m³/h、GPM、L/m

Infrared communication interface

Supports multiple protocols such as M-BUS

Communication and signal types

standard configuration
Terminal number
definition
1
485+(A)
2
485-(B)
3
DC8-36V
4
GND (can be used as a 485 grounding terminal)
Optional
Terminal number
definition
1
Two wire system 4-20mA (can be powered by 24V)
2
OCT1 (open collector output 1)
3
OCT2 (open collector output 2)
4
C1 (TTL level pulse output 1)
5
C2 (TTL level pulse output 2)

Note: The above communication interfaces or output signals can be selected to be led to an external waterproof junction box at the time of ordering.

purpose

1. Measurement of liquids such as water and seawater

2. Water supply and drainage

3. Energy saving monitoring and water-saving management

4. Leakage monitoring

5. Traffic inspection, traffic tracking and collection

6. Heat measurement and heat balance

error-curve

误差曲线
Q1- Minimum Flow

Q2- Boundary Flow

Q3- Common Traffic

Q4- Overload Flow

pressure loss

压力损失

Flow range

Nominal diameter (mm)
Range ratio R
Flow rate (m ³/h)
Start flow rate
Minimum flow Q1
Boundary flow Q2
Common traffic Q3
Overload flow Q4
DN15
200
0.003
0.0125
0.02
2.5
3.125
DN20
200
0.0035
0.016
0.026
3.2
4
DN25
200
0.007
0.02
0.032
4
5
DN32
200
0.01
0.032
0.05
6.3
7.875
DN40
200
0.015
0.1
0.16
20
25
DN50
100
0.03
0.4
0.64
40
50
DN65
100
0.059
0.63
1.008
63
78.75
DN80
100
0.064
1
1.6
100
125
DN100
100
0.094
1.6
2.56
160
200
DN125
100
0.12
2
3.2
200
250
DN150
100
0.27
2.5
4
250
312.5
DN200
100
0.315
4
6.4
400
500
DN250
100
0.508
4
6.4
400
500
DN300
100
0.77
6.3
10.08
630
787.5

Dimension

DN15-DN40

Company: mm

Nominal Diameter
External dimensions
threaded
Effective thread length
Weight kg
Pressure rating bar
L
H1
H2
W1
W2
DN15
110
15
94
47.5
56
G3/4
10.0
0.87
16
DN20
130
17.5
97
47.5
56
G1
12.5
0.94
16
DN25
160
22.5
100
47.5
56
G1 1/4
13.0
1.24
16
DN32
180
25
102
47.5
56
G1 1/2
14.5
1.36
16
DN40
200
33.5
106
47.5
56
G2
16.0
1.89
16

尺寸及重量
尺寸及重量
尺寸及重量

DN50-DN300

unit mm

Nominal Diameter
External dimensions
Flange size
Weight kg
Pressure rating bar
L
H1
H2
W1
W2
Outer diameter D
Bolt hole center circle diameter D1
Bolt hole diameter × quantity Φ × n
Sealing surface
Flange thickness C
D2
f
DN50
200
70
131
76
95
165
125
18×4
102
2
19
10
16
DN65
200
75
135
79
95
185
145
18×4
122
2
20
11.5
16
DN80
225
94
132
94
95
200
160
18×8
138
2
20
13.6
16
DN100
250
104
140
104
104
220
180
18×8
158
2
22
18.6
16
DN125
275
117
148
117
117
250
210
18×8
188
2
22
23.5
16
DN150
300
134
155
114
114
285
240
22×8
212
2
24
30
16
DN200
350
165
254
165
165
340
295
22×12
268
2
26
35.558
16
DN250
450
197
269
197
197
405
355
26×12
320
2
29
58
16
DN300
500
223
287
223
223
460
410
26×12
370
2
32
76
16

尺寸及重量
尺寸及重量

Model Selection Table

FU50- Pipeline ultrasonic flowmeter (ultrasonic water meter) (online)
FU50E- External clamp type ultrasonic flowmeter (ultrasonic water meter) (portable non pipeline type)
orifice
DN15 caliber, threaded connection, external thread G3/4
DN20 caliber, threaded connection, external thread G1
DN25 caliber, threaded connection, external thread G1 1/4
DN32 caliber, threaded connection, external thread G1 1/2
DN40 caliber, threaded connection, external thread G2
DN50 caliber, flange connection, 16 bar
DN65 caliber, flange connection, 16 bar
DN80 caliber, flange connection, 16 bar
DN100 caliber, flange connection, 16 bar
DN125 caliber, flange connection, 16 bar
DN150 caliber, flange connection, 16 bar
DN200 caliber, flange connection, 16 bar
DN250 caliber, flange connection, 16 bar
DN300 caliber, flange connection, 16 bar
Output signal and power supply type
3.6V lithium battery (display only for selection)
RS485 DC8~36V
4-20mA DC24V
M-Bus remote meter reading system (symmetrical mbus)
Optional signal
No options available
TTL level pulse output
2-channel normally open signal
Material of the liquid receiving body
Brass alloy structure UNI EN 12165 CW617N
nodular cast iron
carbon steel
Stainless steel 1.4301 (304)
(Special alternative) VARIO
No customization function
Protocol customization function
The above selection table does not include selection codes. If you need selection codes, please contact us or fill in your information
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!