Sichuan Fagao Electric Co., Ltd
Home>Products>FMS300 Intelligent Soft Starter Device
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18080478713
  • Address
    Building 2, No. 166 Wuxing Fourth Road, Wuhou District, Chengdu City
Contact Now
FMS300 Intelligent Soft Starter Device
The product is widely used in motor transmission equipment in important national industrial fields such as metallurgy, petroleum, fire protection, min
Product details

FMS300 Intelligent Soft Starter Device


Product Introduction

The FMS300 series intelligent motor soft starter device is based on an advanced sixteen bit microprocessor and controls a high-power thyristor module to achieve soft start and soft stop functions for three-phase AC 380V asynchronous motors (squirrel cage type). It also has multiple optional protection functions such as overload, phase loss, overvoltage, undervoltage, etc. This product is mainly used in conjunction with a complete set of control cabinets, and requires the connection of corresponding specifications of bypass contactors during use. The product specifications cover 5.5KW~600KW three-phase AC asynchronous motors (squirrel cage type).

The product is widely used in motor transmission equipment in important national industrial fields such as metallurgy, petroleum, fire protection, mining, and petrochemicals. It is an ideal replacement product for traditional star delta starting, reactor starting, and autotransformer pressure reducing starting.


Product Features

Three starting methods: voltage ramp starting, current limiting starting, and heavy load starting

◆ Voltage ramp soft parking, free parking

◆ Programmable delayed start mode, can be turned into chain control, programmable fault contact output

◆ No phase sequence requirement for input power supply

The starting time and stopping time can be programmed and modified

◆ Multiple protection functions such as overcurrent, three-phase current imbalance, overheating, phase loss, motor overload, etc

◆ Dynamic fault memory function, easy to find the cause of faults

◆ Can search for the maximum starting current and maximum operating current of three phases online

◆ Digital tube code display and LCD screen Chinese character display are optional



PRODUCT FUNCTION

Start mode

Current limiting: limit starting current, reduce starting voltage drop, adjust freely, keyboard settings

Voltage ramp type: provides a smooth and gradual starting process for the electric motor, reduces the impact of starting current on the power grid, lowers equipment vibration and noise, and extends the life of mechanical transmission

Heavy load starting type: capable of outputting maximum starting torque


Parking method

Free parking

soft stop


control mode

Input: Passive switch signal

Output: Passive contact of relay


system control function

Equipped with programmable input and output contacts, built-in with various load intelligent programs, real-time detection of system operating conditions

Comes with a Chinese menu for human-machine dialogue, setting various parameters and programming, etc

Analog current signal 4-20mA output function

Equipped with keyboard control and remote control switching function to ensure the safety of equipment maintenance personnel

Delay relay function, programmable output contact time of delay relay

Fault output relay, if the system malfunctions, this relay will activate, and the fault will shut down and reset automatically, which is programmable

The output relay of the self-control bypass contactor will activate when the starting process is completed

Delay start function, can set a delay start of 0-240s, and has a countdown display (two-wire control mode is effective)

Can achieve a soft start to drive multiple electric motors


System protection function

Built in electronic quick break protection, does not require external acceleration of melting. If there is a short circuit fault in the lower port before starting, during starting, running, or soft stop, the system can achieve self-protection and alarm action

Overvoltage protection

overload protection

open-phase protection

Phase reversal prevention protection: The upper port will not start and will sound an alarm if it is reversed (optional)


maintenance function

Fault self diagnosis (short circuit, overvoltage, overload, phase failure, locked rotor)

Fault display and relay contact output


Parameters

Motor power (at AC400V)/kW 5.5~600kW
Rated working current Ie/A 10~1200A
Continuous working current/A 115%Ie
Rated working voltage/V AC380V(-15%~10%)
Frequency/Hz

50Hz

Compliant with standards GB14048.6-2008
protection grade IP20
Seismic resistance Below 3000 meters above sea level, vibration device above 0.5G
Impact resistance 15kg/11ms
ambient temperature -30~55℃
ambient humidity 95% without condensation or water droplets


Typical Connection Diagram



If you need detailed information or the latest product information, please send your name, contact information, and company name tosale@foago.comOr call -8002 to request, thank you for your attention and support to our company!

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!