DIGMESAIt is a well-known manufacturer of filling machinesKHSOur partners,DIGMESAThe product has a high market share in the European and American markets90above. Leader in the micro flowmeter industry, SwitzerlandDIGMESAThe Digmansha miniature flowmeter product is renowned for its outstanding performance and compact structure.DIGMESAIt enjoys a high reputation in Europe and is widely used in the fields of food, chemical, biotechnology, medicine, and semiconductor.
FM15 935-3901/PNP DIGMESAThe flow meter isFM15 Grivory 3900The upgraded product is widely used in beverage canning and is a world-renowned canning equipment manufacturerKHSThe supplier,FMFlow range2.83-67.5L/minAccuracy ±1%Repeatability ±0.25%,The pressure is20At ℃20bar,temperature-10-+100℃, signal output modeNPNperhapsPNP, maximum speed1900rpm,Adopting gemstone ceramic bearings, equipped with flow curve and pressure loss curve. nozzle size15mm.
FM15 935-3901/PNP DIGMESAWhen cleaning a flowmeter, the first thing to ensure is that there is no reverse pressure. Liquids should not flow in pulses.FMDuring installation, it should be installed horizontally and pay attention to the direction of the inlet and outlet. Import and export pipelines should avoid shaking during filling,
FM15 935-3901/PNP DIGMESAFlow meters can be used2.5%ofNaOHRinsing is possible. But be careful not to use compressed gas to blow the pipeline when there is no liquid after flushing, otherwise the high-speed rotation of the flowmeter impeller will damage it!
FM15 935-3901/PNP DIGMESAPrecautions for using flow meters
•Ensure that there is no fast-pulsatory movement of the media
Ensure that the medium does not experience rapid pulsating flow
•Ensure that there are no reverse pressure surges
Ensure there are no reverse pressure fluctuations
•Ensure that there is no air in the system
Ensure that there is no air in the system
•Keep the pressure loss as small as possible
Ensure minimal pressure loss
•Note the mounting position of the flowmeter
Pay attention to whether the installation position of the flow meter is correct
•Min/max flow should be in the linear range of the selected flowmeter
The minimum and maximum flow rates should be within the linear range of the selected flowmeter
•Clean the system at appropriate intervals
Clean the system at appropriate intervals
•Avoid electrical current peaks
Avoid peak current
•Incorrect cabling of power supply +, signal and ground will destroy the flowmeter
Incorrect wiring, power supply+Signal and grounding will damage the flowmeter
•Do not mechanically load electrical contacts
Do not apply mechanical loads on electrical connectors
•Avoid moisture on the electrical contacts
Avoid moisture at electrical connection points
•Avoid stray pick-up via the cable (Do not lay cables in parallel with high current loads)
Avoid noise pickup (Do not arrange wiring cables in parallel with high current loads)
Guangzhou Minghong Automation Instrument Co., Ltd. SwitzerlandDIGMESAThe Chief Agent,DIGMESAStrategic partnership.DIGMESAOur business in China is divided into three parts, with one company in Taiwan and one in Hong Kong responsible for sales in the mainland market. We visit each other every year for technical exchanges.