Druck thermocouple temperature calibrator from the United States
(DPI821、DPI822)
Product features:
1.DPI821/DPI822 is a measurement and simulation sensor, an ideal tool for checking temperature probes, indicators, recorders, and controllers.
2.Measure/simulate thermocouple signal output
3.*The CJ cold end compensation technology almost avoids errors caused by changes in ambient temperature. For a change in ambient temperature of 30 degrees, the Z-large error is 0.2 degrees
4.Current testing, temperature testing, transmitter calibration, circuit setting and diagnosis, switch value testing
5.Support IDOS pressure module
6.Step wise, ramp wise, Z-large/Z-small/average values and readings are maintained for easy system inspection and troubleshooting
7.Display: 48mm × 48mm LCD with backlight, 99999 five bit resolution
8.Operating environment: Temperature range of -10 to 50 degrees Celsius; 0-90% humidity, non condensing
9.Protection level: IP54, Dustproof and splash proof design
10.Vibration: DEF STAN 66-31, 8.81 and 8.4CAT III
11.ECM: EN61326-1; 1997+A1; 1998+A2; two thousand and one
12.Security: EN61010; 2001, SEP grade, CE mark
13.Size: 180 × 85 × 50 (length, width, thickness, mm)
14.Weight: 0.5Kg
15.Battery: 3 AA batteries, more than 50 hours for measurement, more than 10 hours for 24V circuit power supply
DPI800series |
DPI821 |
DPI822 |
test type |
thermocouple probe |
thermocouple probe |
Indicator (pressure measurement) |
|
|
Calibration instrument (measurement/analog output) |
correct |
correct |
Temperature display instrument (dual input/differential) |
|
|
0-55MAMeasurement (providing 24V power supply) |
|
correct |
Switch quantity test |
|
correct |
HARTloop resistance |
|
correct |
IDOSIntelligent digital pressure module |
Note 1 |
Note 1 |
Programmable stepper/ramp output |
correct |
correct |
Reading retention/Z small/Z large/average/alarm/migration |
correct |
correct |
25Pressure unit, flow quantification, leakage testing |
Note 2 |
Note 2 |
1000Point data storage, RS232 interface |
Note 3 |
Note 3 |
Note 1: For the external pressure module, please refer to the IDOS list
Note 2: When used in conjunction with IDOS pressure module
Note 3: Refer to option E
type |
standard |
range |
accuracy |
K |
IEC 584 |
-270Up to 1370 degrees |
0.6linear measure |
J |
-270Up to 1200 degrees |
0.5linear measure |
|
T |
-270Up to 400 degrees |
0.3linear measure |
|
B |
50Up to 1820 degrees |
1.0linear measure |
|
R |
-50Up to 1769 degrees |
1.0linear measure |
|
S |
-50Up to 1769 degrees |
1.4linear measure |
|
E |
-270Up to 1000 degrees |
0.4linear measure |
|
N |
-270Up to 1300 degrees |
0.6linear measure |
|
L |
DIN43710 |
-200Up to 900 degrees |
0.3linear measure |
U |
-200Up to 600 degrees |
0.3linear measure |
|
C |
0Up to 2320 degrees |
1.0linear measure |
|
D |
0Up to 2495 degrees |
1.0linear measure |
|
MV |
-10Up to 100mv |
DPI822*Characteristics:
1.Measure 0-55.000mA with an accuracy of 0.02% of the reading plus 3 final words (including temperature effects of 10-30 degrees)
2.Temperature coefficient: -10 to 10 degrees, 30 to 50 degrees, 0.002% PS/degree
3.Switch detection: open and close, 2mA current
4.Circuit power output: 24V ± 10% (Z high current 35mA)
5.HartLoop resistance: 250 Ω (menu selection)
6.Electrical socket: 4mm socket
Item number |
product description |
DPI821 |
Thermocouple temperature calibrator |
DPI822 |
Thermocouple temperature calibrator |