Shanghai Zequan Technology Co., Ltd
Home>Products>DT80M Data Collector
DT80M Data Collector
Instrument features Ø Ultra low power design Ø Embedded cellular modem Ø Automatic data transfer to email or FTP Ø Up to 15 analog channel inputs Ø Sc
Product details
Instrument characteristics



DT80M.jpg

Ø Ultra low power design

Ø Embedded cellular modem

Ø Automatically transfer data to email or FTP

Ø Up to 15 analog channel inputs

Ø Up to 300 analog channel inputs can be expanded

Ø 12A flexible digital channel

Ø Modbus SCADA connection

Ø Multiple SDI-12 channels













Software Features










Ø The software is built-in and does not require installation, and can be used on computers with Windows, Mac, and Linux operating systems

Ø Setting up instruments through web pages

Ø Connect to the instrument via Ethernet cable, USB data cable, or wireless connection

Ø Intuitive graphical interface

Ø Simple setup interface, convenient for users of all levels

Ø Can view real-time and historical data
















application area










Meteorological stations, agricultural research, environmental monitoring, system development, energy monitoring, aquaculture, flow monitoring, mechanical testing, thermistor matrix, etc














System Introduction










Display and buttons

Type: LCD display, 2 lines of 16 characters, backlight;

Display function: channel data, alarm information, system status;

Button: View display information and operation functions through 6 buttons;

Signal LED lights: 4 signal lights, indicating sampling, hard disk, alarm information, and power supply respectively;

Software version upgrade

Upgrade software through Ethernet cable, USB data cable or USB flash drive;

clock

Basic resolution: 200 µ s;

Accuracy: ± 1 minute per year (in an environment with a 0 ℃ value of 40 ℃), ± 4 minutes per year (in environments with -40 ℃ to 0 ℃ and 40 ℃ to 70 ℃);

power supply

External power supply range: 10 to 30Vdc;

Peak power: 12W;

Average electrical loss

The relationship between sampling frequency and power consumption when using a 12Vdc external power supply is shown in the following table:

blob.png

basic feature

Numerical shell: Zinc aluminum alloy;

Size: 300 x 137 x 65mm;

Weight: 2.5kg;

Operating temperature: -30 ℃ to 70 ℃;

Operating humidity: 85%, water vapor does not condense;

Note: Low and high temperature environments can reduce battery life,LCDThe working temperature of the display screen is-15℃ to50℃.

built-inModem

Alarm: Sending emails or SMS messages;

Data: Send data to email or FTP server;

Remote access: connect to dEX or command interface;

SIM panel: SIM card interface (1.8V/3V);

Network: EDGE, GPRS, GSM, WCDMA, HSUPA, HSDPA

Frequency: EDGE/GPRS/GSM: 850/900/1800/1900 MHz; WCDMA/HSUPA/HSDPA: 850/1900/2100 MHz
















analog channel










The DT80M has 5 analog channels and can be expanded up to 100 analog channels. Each analog channel can be connected to a three wire or four wire input, two independent two-wire inputs, or three single ended two-wire inputs.

The specific number of connections is as follows:

Two wire single ended channel: 15 (up to 300 expandable);

Two line differential channels: 10 (up to 200 expandable);

Three wire or four wire differential channels: 5 (up to 100 extensions);

Note: Expansion requires configurationCEM20Module, a module contains20A simulated channel.

Basic input range

The basic input voltage, current, resistance, and frequency range that can be measured by DT80M are as follows:

blob.png

Note: The data collector has an automatic range setting function and can switch between three ranges.

The basic input voltage, current, resistance, and frequency accuracy that DT80M can measure are as follows:

blob.png

Note: Accuracy relative to full scale.

Sampling information

In order to ensure measurement accuracy and suppress the influence of noise, a line frequency period greater than 50/60Hz is integrated.

Maximum sampling speed: 25Hz;

Effective resolution: 18 bits;

Linearity: 0.01%;

Common mode rejection: 90dB;

lineSexual stringing inhibition: 35dB.

input

Channel isolation: 100V (relay open state);

Analog component isolation: 100V (photoelectric isolation);

Input impedance: 100K Ω,> 100MΩ;

Common mode range: ± 3.5V, or ± 35V in the 30V range

Sensor excitation

Simulation channel excitation: optional 250 µ A or 2.5mA precision current source, 4.5V voltage, switchable external power supply;

Universal excitation: The 12V power supply (maximum 150mA) can be turned on and off to power sensors and accessories, and the 5V power supply (maximum 25mA) can be turned on and off to power analog channels.
















Analog sensor









Introduce several common sensors, but the sensors that can be connected to DT80 are not limited to the following types.

thermocouple

Thermocouple types: B, C, D, E, G, J, K, N, R, S, T type;

Thermocouple calibration: ITS-90;

RTDs

RTD material type: Pt,Ni,Cu;

Resistance range: 10 Ω to 10K Ω;

thermistor

Thermistor type: YSI400xx series;

Resistance range: < 10kΩ

Note 1: Other types of thermistors are also supported.

Note 2: The measurement range can be expanded by parallel resistors.

Single chip temperature sensor

Support type: LM34-60,AD590/592,TMPxx,LM135/235/335;

Strain gauges and bridge sensors

Configuration: 1/4 bridge, 1/2 bridge, and full bridge;

Excitation: voltage or current;

4-20mACurrent loop

Internal 100 Ω or external shunt resistor.
















DIGITAL CHANNEL










digital input/output

8 bidirectional channels

Input type: 8 logic levels (maximum 20/30V);

Output type: 4 field-effect transistors (maximum: 30V, 100mA), 4 logic outputs;

Relay

1 direct self-locking relay (maximum: 30Vdc, 1A).
















counting channel










Low speed counting

8-channel counter, shared with digital channel; The low-speed counting function does not work in sleep mode.

Model: 32-bit;

Maximum counting rate: 10Hz;

Dedicated counting input

4 high-speed or 2 phase encoder inputs

Model: 32-bit;

Maximum counting rate: 100kHz;

Input type: 2 logic level inputs (maximum ± 30V). 2 magnetic induction (maximum ± 10V) sensitive inputs (10mV).
















Serial channel










SDI-12

Four SDI-12 channels shared with the digital channel, each SDI-12 channel can connect multiple SDI-12 sensors;
















Calculation channel








The calculation channel can perform arithmetic, trigonometric, correlation, logical, and statistical analysis on the data collected by the data collector from analog, digital, or serial channels.














call the police










Condition: Below, above, within range, or outside range;

Delay: optional alarm response time;

Action: Digital output, transmitting information or executing any datataker command.
















Data Collection List









Number of schedules: up to 11;
Sampling interval for schedule: Each schedule has a separate sampling time interval, ranging from 10ms to days.















Data Storage










Built-in storage

Storage space: 128MB, capable of storing approximately 10 million pieces of data (large memory space can be customized);

External storage device

USB 1.1, USB 2.0 and other USB flash devices.















Communication panel








Ethernet port

Panel: 10Mbps;

Protocol: TCP/IP, Modbus protocol;

USBport

Panel: USB1.1 (virtual communication interface);

Protocol: ASCII commands;

Serial sensor port

Panel: RS232,RS422m,RS485;

Speed: 300 to 115200 baud rate;

Flow control: hardware (RTS/CTS);

Software (XON/XOFF): None

Protocol: Modbus protocol, serial sensor;
















Network services(TCP/IP









Use Ethernet ports or built-in modems

Command panel: Enter the ASCII command panel of DT80M through TCP/IP;

Network server: Accessing existing data and data collection status through web pages, setting up user specific display interfaces, and downloading CSV format data;

Modbus server (controlled end): obtains data and data acquisition status through Modbus client;

Modbus client (master): reads data from Modbus devices or writes data to Modbus devices;

FTP server: retrieves stored data through a browser or FTP client;

FTP client: Automatically downloads data to the FTP server.

Email client: receives data and warning messages from the data collector;

DDNS client: Pain over dynamic DNS remote access data collector

















Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!