Beijing Zhiyang Technology Co., Ltd
Home>Products>DLI-400 optical integrator/photoperiod meter
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    134263840471881025936913381286230
  • Address
    Room 1306, Unit A, Building 1, No. 13 Beiyuan Road, Chaoyang District, Beijing
Contact Now
DLI-400 optical integrator/photoperiod meter
The DLI-400 light integrator/photoperiod meter is used to measure the photosynthetically active radiation (PAR) of sunlight at 370-650nm, and can also
Product details

The DLI-400 light integrator/photoperiod meter is used to measure the photosynthetically active radiation (PAR) of sunlight at 370-650nm, and can also calculate the daylight integral (DLI) and photoperiod.

PAR, DLI, and photoperiod affect plant growth and development, and are typically measured in greenhouses and growth chambers to aid in light management and decision-making. DLI refers to the total amount of PAR or Extended PAR (ePAR) incident on a plane within 24 hours, measured in µ mol/m ² s. The photoperiod is the total time of PAR or ePAR incidence within 24 hours, expressed in hours (h).

The DLI-400 measuring instrument has two different screen modes: storing data and real-time viewing data. In the data storage screen, it displays DLI measurement values, lighting time, and data collected on which day (up to 99 days ago). Real time viewing of data screen displaying the average running value of PPFD over the past 2.5 seconds.

No corresponding parameter group found, please add it in the backend property template

Measurement repeatability

Less than 0.5%

Display Range

0 ~ 4000μmol/m2s

Long-term Drift

<2%/year

field of view

180°

Spectral measurement range

370~ 650nm(Taiyangguang)

Directional (cosine) response

± 5% (75 ° zenith angle)

Temperature response

-0.04 % /

response time

2.5s

Measurement Frequency

3minute

Data recording capacity

99Days (DLI and photoperiod)

10Days (30 minute PPFD/ePPFD average)

Nonlinear

<1%(< 2500μmol/m2S time)

Data Resolution (PPFD)

0.1μmol/m2When s is greater than or equal to 1000, the screen does not display decimals

Storage Data Resolution (DLI)

0.1mol/m2d

Storage data resolution (photoperiod)

0.1hour

data transmission

Connect USB-C and CSV files

Resolution of analog-to-digital converter

24position

work environment

-10℃ ~60 ℃,0~100% RH

protection grade

IP65

power supply

AAA(7th) x2 batteries, replaceable, approximately 6 months

quality

67g

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!