Beijing Guancheng Measurement Technology Co., Ltd
Home>Products>DB306 cable type static pressure level gauge
DB306 cable type static pressure level gauge
DB306 cable type static pressure level gauge
Product details

Product Features

Adopting imported ceramic sensors, air conducting extension cable structure, unique anti blocking flat film design, superior seismic resistance

Dynamic, impact resistance, extensive anti-corrosion performance, high measurement accuracy (0.1%, 0.2%), extremely strong applicability, with

There are analog, intelligent, explosion-proof, and intrinsic safety types, suitable for measuring the liquid level of industrial wastewater, surface water, and seawater.


Working principle

The pressure sensor probe is placed in the measured liquid and subjected to a certain static pressure of the medium (P). This pressure is related to the measured liquid

The liquid level height (h, m) of the body is proportional to P=ρ gh (Pa), where ρ is the specific gravity of the medium (g/cm3) and g is

The local gravitational acceleration (m/s2) is constant for the measured medium and location, where ρ and g are constant. The electronic components of the transmitter will apply pressure

The liquid level pressure signal measured by the force sensor is transmitted to the display instrument, and the liquid level signal of the medium is displayed through circuit conversion.



Technical Parameter

·Measurement range

Minimum 0~0.5m, maximum 0~350m

·Measurement accuracy

(Comprehensive errors include linearity, hysteresis, and repeatability)

0.5% FS, 0.2% FS, 0.1% FS (with a maximum accuracy of 0.2% for ranges below 0.7 meters)

·Long term stability

Better than 0.1% annually

·Allowable medium temperature

-20℃~80℃

·Allow ambient temperature

-40℃~85℃

·Allow storage temperature

-40℃~85℃

·Temperature influence

0.5% accuracy level -20 ℃~80 ℃: every 10K+0.15% for other temperature ranges, every 10K ± 0.2%

0.2%, 0.1% accuracy level 20 ℃~80 ℃: every 10K+0.1%, other temperature ranges every 10K ± 0.15%

·Material of the part in contact with the medium

·Ceramic capacitive sensor

96% alumina ceramic

·Measuring sensor housing

Stainless steel 304 (special requirements agreed upon)

·Air conducting cable

polyurethane

·Sensor counterweight

Stainless steel 304 (special requirements agreed upon)

·Material of non-contact parts with the medium

·Electronic component housing

ABS junction box IP67; Stainless steel 304 IP66; Die cast aluminum epoxy coating IP66

·Process installation connectors

Stainless steel 304

·Working voltage

(12.5~30V DC)

·Electrical parameters

Working voltage (12.5~30V DC)

·Signal output

Analog two-wire system 4-20mA

Intelligent two-wire 4-20mA with HART communication protocol

·Monitor

3 1/2 digit digital LCD display suitable for analog and intelligent types

·Cable entry hole

Internal thread M20 × 1.5 (special requirements agreed upon)

·Analog cable

Three core instrument cable

·Intelligent cable

Suggest using shielded twisted pair cables for wiring

·Preheating time

Simulated 200ms; Intelligent type: 2s

·Response time

Simulation type: 60ms; Intelligent type: 230ms

·Damping

(limited to stainless steel shell and die cast aluminum shell only) Analog type: 2s; Intelligent type: 0-40s

·Electromagnetic compatibility

The radiation immunity of radio frequency electromagnetic fields complies with GB/T17626.3-1998 10V/m and meets Class A standards;

The conduction impedance of RF field induction complies with GB/T17626.6-1998, U=10V, and meets Class A standards

·Allow environmental humidity

100%HR

·Process Connection Standard

Card sleeve installation: pipeline installation; Card sleeve installation: wall mounted installation; Split installation

External thread G11/2A; Flange DN40 PN0.6MPa GB9123-2000; Special requirements agreed upon



Exterior structure



Electrical connection


load characteristics


Installation method



Communication protocol



DB series intelligent liquid level gauge with remote communication function
Overlay a digital signal on the 4-20mA two-wire output signal of the level gauge transmitter to achieve the HART communication protocol standard
Several functions. The functional implementation includes the following: manual operation using the HART communication protocol or a microcomputer (requires configuration)
The HART communication protocol software interface can remotely calibrate the zero point and full range values of the liquid level transmitter, display the temperature value of the medium, and indicate whether it has been used
Pressure level value, adjust damping value, achieve self diagnostic function of the measurement system, display various fault states represented by fault codes
Location and reason.



Order Selection Table



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!