Guangdong Zhongzhi Testing Instrument Co., Ltd
Home>Products>Continuous salt spray test chamber CZ-60A/CZ-90A/CZ-120A
Continuous salt spray test chamber CZ-60A/CZ-90A/CZ-120A
The salt water spray test is to test the corrosion resistance of the products after the surface of various materials has undergone anti-corrosion trea
Product details
The Zhongzhi Salt Spray Box Type A series can complete many accelerated corrosion tests, including ASTM B117,GB/T2423.17/IEC 60068-2-11, JIS H8502, GB/T10125-2012/ISO 9227-2006, GJB150.11A-2009 , Waiting for experimental methods. Model A salt spray box is our most economical model, which can conduct continuous spray test

Execution standards and testing methods
  1. GB/T 2423.18-2000 Alternating Salt Spray Test Method
  2. GB/T 6461-2002 Grade Evaluation
  3. ASTM.B117-2009 Salt Spray Test
  4. JIS H8502 Salt water spray test method
  5. IEC 60068-2-11:1981 Salt spray test
  6. IEC 68-2-52 1996 Salt Spray Test
  7. GB/T 6461-2002 Salt Spray Test Evaluation Criteria
  8. ISO 9227-2006 Salt water spray test method
  9. GB/T 12967.3-91 CASS Accelerated Acetate Salt Spray Test
  10. QB/T 3828-1999 Copper Salt Accelerated Acetic Acid Salt Spray Test
  11. GB/T 5170.8-2008 Salt Spray Test Equipment Inspection Method
  12. GB/T 5170.11-2008 Inspection Methods for Corrosion Gas Testing Equipment
  13. GJB 150.11A-2008 Salt Spray Test Method
  14. GB/T 2423.17-2008 Salt Spray Test Method
  15. GB/T 10587-2006 Technical Conditions for Salt Spray Test Chamber
  16. CNS 8886-2002 Determination of Salt Spray Corrosion Degree
  17. CNS 4159 Copper acetate brine spray test method
  18. CNS 4158 Salt water spray test method
specifications
model CZ-60A CZ-90A CZ-120A CZ-160A CZ-200A
Laboratory box size LxWxH (cm) 60x45x40 90x60x50 120x80x50 160x100x50 200x120x60
Test outdoor box size LxWxH (cm) 107x60x118 141x88x128 190x110x140 230x130x140 270x150x150
Laboratory temperature Saltwater test method (NSS ACSS) 35 ℃± 1 ℃/Corrosion resistance test method (CASS) 50 ℃± 1 ℃
Pressure bucket temperature Saltwater test method (NSS ACSS) 47 ℃± 1 ℃/Corrosion resistance test method (CASS) 63 ℃± 1 ℃
Salt water temperature 35℃±1℃ 50℃±1℃
Laboratory capacity 108L 270L 480L 800L 1440L
Salt water tank capacity 15L 25L 40L 40L 40L
brine concentration Add 0.26 grams of copper chloride (CuCl2 2H2O) per liter to a concentration of 5% sodium chloride solution or 5% sodium chloride solution
Compressed air pressure 1.00±0.01kgf/cm2
Spray amount 1.0~2.0ml/80cm2/h (Collect for at least 16 hours and take the average)
Relative humidity in the laboratory Over 85%
PH value 6.5~7.2 3.0~3.2
spray mode Continuous spray
power supply AC220V1Φ10A AC220V1Φ15A AC220V1Φ20A AC220V1Φ20A AC220V1Φ30A
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!