Continuous Supercritical Separation Unit for Deasphalted Crude Oil,Continuous Supercritical Separation Unit for Deasphalted Crude OilProfessional production,Factory direct sales,Quality supplier
(Non standard customization)
- Specification
- working pressure:20Mpa
- Working temperature: room temperature-250℃
- Processing capacity:10L/h
- Total power of the device:20KW
- Power supply: AC380V
- Technical parameters of each component in the composition device
- Solvent tank
volume10L, pressure2.5MPa, with liquid level display, quantity2Platform, compatible, material304, takeover specifications ¢8×1.5.
- Solvent flowmeter
range20L/h, withstand voltage2.5MPa, Material304Electric remote transmission.
- Main solvent pump
Double plunger pump, displacement10L/h, pressure25MPaExplosion proof.
- Secondary solvent pump
Double plunger pump, displacement4.6L/h, pressure25MPaExplosion proof.
- Heavy oil tank and heating temperature control system
volume5LEquipped with heating and temperature control system, heating power1.5KWTemperature control range: room temperature-200℃. material304, takeover specifications ¢8×1.5.
- Light oil tank and heating temperature control system
volume5LEquipped with heating and temperature control system, heating power1.5KWTemperature control range: room temperature-100℃. material304, takeover specifications ¢8×1.5.
- heavy-oil pump
Double plunger pump, displacement10L/h, pressure25MPaExplosion proof.
- Light oil pump
Double plunger pump, displacement4.6L/h, pressure25MPaExplosion proof.
10Main solvent preheater
Preheat the main solvent, preheating temperature range: room temperature-250℃, using a tubular preheater with pipe specifications ¢8×1.5mm, Length15m, Material304, withstand voltage16MpaPreheater power2.5KW.
11Secondary solvent preheater
Preheat the secondary solvent within the temperature range of room temperature-250℃, using a tubular preheater with pipe specifications ¢8×1.5mm, Length15m, Material304, withstand voltage16MpaPreheater power2.5KW.
12Light oil preheater
Preheating for light oil, preheating temperature range: room temperature-250℃, using a tubular preheater with pipe specifications ¢8×1.5mm, Length15m, Material304, withstand voltage16MpaPreheater power2.5KW.
13Primary extraction tower
Volume:2000ml
Pressure:16Mpa
Temperature: Room temperature-200℃
Takeover: ¢8×1.5mm
texture of material:304
Structure: Sealed with upper and lower flanges, built-in2Group temperature measurement.
14Heating and temperature control system for primary extraction tower
Temperature control range: room temperature-200℃, using electric heating insulation method,PIDIntelligent temperature control, heating power2KW.
15Product preheater at the top of the extraction tower
Preheat the product at the top of the extraction tower, with a preheating temperature range of room temperature-250℃, using a tubular preheater with pipe specifications ¢8×1.5mm, Length15m, Material304, withstand voltage16MpaPreheater power2.5KW.
16Two stage precision separator
Specification: Internal dimensions ¢60×2500mm
Pressure:16MPa
Takeover: ¢8×1.5mm
texture of material:304
Structure: Sealed with upper and lower flanges, built-in2Group temperature measurement.
17Heating and temperature control system for two-stage precision separator
Temperature control range: room temperature-200℃, using electric heating insulation method,PIDIntelligent temperature control, divided2Segment heating,2Temperature control for each section, heating power for each section2KW.
18Second stage solvent recovery device
Volume:1000ml
Pressure:2.5Mpa
Temperature: Room temperature-200℃
Takeover: ¢8×1.5mm
texture of material:304
Structure: Sealed with upper and lower flanges, built-in1Group temperature measurement.
19Heating and temperature control system for two-stage solvent recovery device
Temperature control range: room temperature-200℃, using electric heating insulation method,PIDIntelligent temperature control, heating power1.5KW.
20Cooling device
Using water cooling method to cool the recovered solvent at the back pressure inlet and after the three-stage separator. Cooling coil specifications ¢8×1.5mm, Length10m, Material304.
21Back pressure controller
Used for system pressure control, pressure control range0-16Mpa.
22Three stage separator
Volume:2000ml
Pressure:2.5Mpa
Temperature: Room temperature-200℃
Takeover: ¢8×1.5mm
texture of material:304
Structure: Sealed with upper and lower flanges, built-in1Group temperature measurement.
23Three stage separator heating and temperature control system
Temperature control range: room temperature-200℃, using electric heating insulation method,PIDIntelligent temperature control, heating power1.5KW.
24Pressure measurement
Using pressure transmitters and gauges to measure pressure, including pressure measuring points4Location of pump outlet, first stage extraction tower, second stage precision separator, second stage solvent recovery device, third stage separator, etc.
25Valves, fittings, pipelines
useDW8Card sleeve globe valve, card sleeve pipe fittings, ¢8×1.5mmPipeline, pressure resistant25MPa, temperature resistance250℃, material304.
26Automatic control and data acquisition system
Software inwindows 7Operating in the environment, usingVBProgramming. The workflow of the instrument is displayed on the interface, enabling human-machine dialogue. After the operator sets the parameters, unmanned operation can be achieved. The computer can automatically collect all pressure, temperature, and flow rates, and control the operation of the pump.
The data collected by the computer can be processed to generate raw data reports, analysis reports, and curve graphs. At the same time, the database file format can be customized for users to use flexibly.
Computer: Lenovo4600,23"liquid crystal display