sensor |
measurement |
Black Spot DARK SPOT ™ Fixed sample gas analysis. Direct optical path detection of hydrocarbon condensation at the dew point temperature point of hydrocarbons |
Sensor cooling |
Automatic cooling through Peltier semiconductor technology |
Maximum range |
-34 ° C HCdp at an ambient temperature of+21 ° C |
accuracy |
± 0.5 ° C hydrocarbon dew point |
Sample gas flow rate |
0.03m³/hr (0.5 Nl/min) |
Dew point detection (optional) |
accuracy |
± 1 ° C-59~+20 ° C dew point ± 2 ° C -100~-60 ° C dew point |
Sample gas flow rate |
1 ~ 5 Nl/min |
Pressure measurement |
model |
Hydrocarbon Dew Point Channel PDCR 1050-3465: 0 ~ 100 barg Water dew point channel PDCR 1050-3574: 0 ~ 210 barg |
accuracy |
±0.25% FS |
Hydrocarbon dew point analyzer |
Gas source |
Natural gas, high pressure 100 barg, sampling system with pressure regulator valve included |
casing |
EExd explosion-proof enclosure with detachable transparent window panel. Internal insulation to prevent condensation formation |
Sample gas interface |
¼" NPT (f) |
work environment |
Indoor/Outdoor -20~60 ° C High 95% RH |
power supply |
90-264 V AC 50/60 Hz, host 200 W; Indoor sampling system 300 W; Outdoor sampling system 400 W |
weight |
Host 22.5kg Sampling system (indoor) 42kg (approximately) Sampling system (outdoor) 57kg (approximately) |
Integrated display |
Touch screen display |
Output and alarm |
Modbus RTU, RS485 @ 9600 baud rate Two 4-20 mA linear (non isolated) outputs, allowing users to freely choose dew point or pressure parameters. Hydrocarbon and water dew point alarms are triggered through software registers. Each channel can integrate a low flow alarm module. |
Options and accessories:
The control module of Condumax II's remote interface integration provides functions such as parameter display, chart and data acquisition, parameter control, and remote diagnosis.
19 "standard rack installation with 6.5" color LCD display and mouse operation.
Dual channel remote digital display, providing readings of selected parameters (any two of hydrocarbon dew point, water dew point, or pressure readings), and a 3.5-bit LED display with secondary analog output and dual channel alarm.
The factory level control integration ActiveX module integrates software programs into a universal factory level software system through the Modbus protocol. |