Cond 7310 laboratory conductivity meter
Product Name: Laboratory Conductivity Meter
Model: inoLab Cond 7310
Brand; Germany WTW
1Cond 7310 laboratory conductivity meterDetailed Introduction
(1) Characteristics
InoLab 7310 is suitable for precise measurement of pH, conductivity, or dissolved oxygen, and is suitable for GLP/AQA laboratories. It has functions such as data recording, USB interface, CMC, and printer selection.
1USB interface, fast data transfer;
2Complete CSV format data transfer;
3Optional built-in printer for data output.
(2)accurate measurement+Documents
The 7310 series provides measurements of pH, conductivity, and dissolved oxygen. Suitable for all laboratory applications that require support for AQA and GLP documentation. These instruments not only provide all the essential features of the 7110 series, but also add some additional functions.
(3)easy operation
The display interface provides convenient and secure operation. All necessary information is displayed on a bright and clear screen, which can be seen at a glance.
(4)Complete Record
For the convenience of transferring general or stored data, the inoLab 7310 series is connected to a PC via a USB interface. A built-in data logger with adjustable storage intervals provides automatic recording of all measurement data. The date, time, and ID number comply with good laboratory practices. Users can also input the sensor serial number to request the complete document. All data can be transmitted in a CSV format that is easy to process; W provides an additional Excel file for recording measurement design and calibration.
InoLab ® 7310P provides a built-in printer for directly printing measurement and calibration results.
IITechnical Parameter
instrument |
inoLab ® Cond 7310 |
|
All values+/-1 word |
conductivity |
0 µS/cm ... 1000 mS/cm +/- 0.5 %Measurement value |
resistivity |
0.00 ... 20 MOhm cm |
Electrode constant |
0.450 ... 0.500 cm-1, 0.800 ... 0.880 cm-1, |
salinity |
0.0 … 70.0 (acc. IOT) |
TDS |
0 … 1999 mg/l, 0 … 199.9 g/l |
Celsius/Fahrenheit |
correct |
temperature |
-5.0 … 105.0 °C +/- 0,1 °C |
Auto Read |
automatic/hand movement |
Sensor plug |
8 pin |
calibration |
one o'clock |
reference temperature |
20 °C/25 °C |
temperature compensation |
NonenLFNonlinear, linear0.000 … 10.00 %/K |
Calibration capacity |
Zui Duo10A correction record |
display |
BacklightLCD |
storage |
500Group Manual/5000Group Automatic |
Recorder |
hand movement/time control |
interface |
miniUSB |
Printer (optional) |
Hot printing,width58 mm |
power supply |
universal power supply, 4x1,5 V AAperhaps4 x 1,2 Vrechargeable battery |
3、 Selection
inoLab ® Cond 7310 |
Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software) andUSBline,Excluding electrodes. |
1CA300 |
inoLab ® Cond 7310 SET 1 |
Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software) andUSBWire, conductive electrodeTetraCon®325,Conductivity Standard1413µS/cm. |
1CA301 |
inoLab ® Cond 7310 SET 6 |
Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software) andUSBWire and pure water conductivity measurement kitUSP KIT1. |
1CA306 |
inoLab ® Cond 7310P |
Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software) andUSBWire, printer, without electrodes. |
1CA300P |
inoLab ® Cond 7310P SET 1 |
Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software)), USBWire, printer, conductive electrodeTetraCon® 325Conductivity standard solution1413µS/cm. |
1CA301P |
inoLab ® Cond 7310P SET 6 |
Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software), USBWire and pure water conductivity measurement kitUSP Kit 1And the printer. |
1CA306P |
TetraCon ® 325 |
Quadrupole conductivity electrode,Cable length1.5mConductivity measurement range:1µS/cm-2S/cm,Apply surface water, groundwater, sewage, food industry, swimming pool water, etc. |
301960 |
KLE 325 |
Two pole conductive electrode, conductivity measurement range:10µS/cm-20mS/cm,Cable Length1.5m. |
301995 |
USP KIT1 |
Pure water conductivity measurement kit that complies with pharmacopoeia. |
300569 |