1WTW dissolved oxygen electrodeDetailed Introduction
(1)StirrOxG electrode
Self stirring dissolved oxygen electrode, while stirring for testing!!
1. One step operation in placeEasy to achieve multiple rapid tests;
2. Traffic * ensures good reproducibility;
3. Can be tested immediately without polarization;
4. Low oxygen consumption, only 0.008ug h-1 (mg/l)-1;
5. No zero drift, no need to calibrate zero point;
6. Standard equipment OxiCal®-ST storage calibration kit;
7. Long service cycle,One time filling of electrolyte is available6 months;
8. IMT temperature compensation,belt2 temperature probes;
9. Film perforation monitoring can indicate film damage.
(2)Cellox 325
Galvanic dissolved oxygen electrode
1. Test immediately without polarization;
2. No zero drift, no need to calibrate zero point;
3. Standard wire length 1.5rice,IP67 connector;
4. Standard equipment OxiCal ®- SL storage calibration kit;
5. Long service cycle,One time filling of electrolyte is available6 months;
6. IMT temperature compensation,belt2 temperature probes;
7. There are also different electrode wire lengths to choose from;
8. Optional mixer RZ300.
(3)DurOx 325
Galvanic dissolved oxygen electrode
DurOx 325 Storage calibration kit SK-D
1. Test immediately without polarization;
2. IMT temperature compensation,belt2 temperature probes;
3. Long service cycle,One time filling of electrolyte is available6 months;
4. Low flow rate requirement;
5. No zero drift, no need to calibrate zero point;
6. Waterproof (IP 68-2 bar);
7. Line length 3Mi, standard waterproof plug(IP 67);
8. Standard equipment OxiCal ®- D storage calibration kit;
9. Standard protective cover SK-D.
IICellox 325 dissolved oxygen electrodeofPurchase Guide
(1) Electrode selection
Item number | model | describe | application |
201570 | DurOx325-3 | DurOx325-3 electrode assembly cable length 3 meters | Sewage aeration tanks and other relatively dirty water with a resolution of 0.1mg/l are only suitable for handheld meters |
201571 | DurOx325-6 | DurOx325-3 electrode assembly cable length 6 meters | |
201533 | CellOx ® 325 | CellOx ® 325 electrode assembly cable length 1.5 meters | Conventional water quality resolution of 0.01mg/l is suitable for desktop handheld meters |
201545 | CellOx ® 325-3 | CellOx ® 325 electrode assembly cable length 3 meters | |
201425 | StirrOx ®- G | Self stirring dissolved oxygen/BOD test electrode assembly | Mainly used for desktop watches |
201300 | FDO925 | Fluorescence method electrode assembly cable length of 1.5 meters | Currently used in conjunction with the handheld watch Oxi3315 |
201301 | FDO925-3 | Fluorescent electrode assembly cable length of 3 meters |
(2) Selection of electrode accessories
Item number | model | describe |
201578 | ZBK-D | DurOx325-3 electrode consumables include three membrane heads, one bottle of electrolyte, and one bottle of cleaning solution |
202706 | ZBK-325 | CellOx ® 325 electrode consumables include three membrane heads, one bottle of electrolyte, and one bottle of cleaning solution |
202710 | ZBK-ST | StirrOx ®- G electrode consumables include three membrane heads, one bottle of electrolyte, and one bottle of cleaning solution |
202740 | WP3-D | DurOx325-3 electrode with 3 replacement cover membrane heads |
202725 | WP90/3 | CellOx ® Replace 3 cap type membrane heads with 325 electrodes |
202738 | WP3-ST | StirrOx ®- Three replacement cover membrane heads for G electrodes |
205204 | RL/G | 30ml cleaning solution |
205217 | ELY/G | 50ml electrolytic solution |
201310 | SC-FDO925 | FDO925 fluorescent cap |
Cellox 325 dissolved oxygen electrode