Carbolite FHA/FHC 1350 ° C tubular furnace

1、 Product Introduction:

Carbolite single zone temperature controlled tube furnace FHA and three zone temperature controlled tube furnace FHC can be used both horizontally and vertically. The maximum temperature is 1300 ° C.

The F series tube furnace has multiple optional accessories. 5mm diameter APM heating wire embedded in ceramic insulation material. Insulation materials have low heat storage, minimal heat loss, and fast heating rate. Using high-quality S-shaped temperature control thermocouples. Up to 8 temperature control zones can be achieved, with precise and uniform temperature control.

2、 Standard parameters:

1. Maximum temperature 1350 ° C

2. 24 segment programmable temperature controller: FHA equipped with EPC3016P1 controller, FHC equipped with CC-T1 controller

3. Over temperature protection

4. The maximum outer diameter of the compatible work tube is 110mm

5. Heating length of 200, 500, 750, 1000 or 1250mm

6. Can be used horizontally or vertically

7. Long service life, stable temperature control

8. High quality S-type temperature control thermocouple

9. Ceramic fiber insulation material with low heat storage capacity

10. The heating element is a high-quality 5mm APM heating wire

11. An independent control cabinet with a 3-meter cable between it and the furnace body, equipped with plugs and sockets

12. Ethernet communication interface

3、 Optional accessories:

1. A series of precision digital controllers with digital communication options, multi-stage programmers and data recorders, as well as digital communication interfaces

2. Various sizes and materials of work tubes are available, such as quartz, ceramic, and metal

3. L-shaped bracket, used vertically

4. Thermal insulation plugs and radiation shielding plugs prevent heat loss and improve temperature uniformity

5. Controllable atmosphere and vacuum components

6. For large-scale work management, please consult us

7. The vacuum system can be equipped with either a mechanical pump or a turbo molecular pump, with a working tube inner diameter of 60mm or more

8. Oxygen probe for inert gas supply system

9. The cable length between the furnace body and the control cabinet is 6 meters

10. Laboratory gas safety system, capable of supplying hydrogen gas above 750 ° C

4、 Technical parameters:

model FHA 13/32/200 FHA 13/32/500

FHA 13/50/200

FHA 13/50/500 FHA 13/50/750 FHA 13/80/200
The maximum outer diameter of the work pipe is the highest (mm) 32 32 50 50 50 80
Heating length (mm) 200 500 200 500 750 200
Maximum temperature (℃) 1350 1350 1350 1350 1350 1350
External dimensions H x W x d (mm) 420 x 400 x 350 420 x 700 x 350 420 x 400 x 350 420 x 700 x 350 420 x 950 x 350 420 x 400 x 350
Weight (KG) 25 30 30 35 40 35
The length of the tube used in the air (mm) 390 690
390
690 940
390
The length of the tube used in the atmosphere (mm) 925 1225
925
1225 1475
925
Control cabinet size H x W x d (mm) 500 x 550 x 700 500 x 550 x 700 500 x 550 x 700 500 x 550 x 700 850 x 550 x 700 500 x 550 x 700
Control cabinet weight (KG) 50 50 50 50 60 50
Average temperature zone length+-5 ℃ 100 250
100 250 375
100
Power (kW) 1.2 2.4
1.5
3.6 5.4 2.1
Power supply a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e
model FHA 13/80/500 FHA 13/80/750 FHA 13/80/1000 FHA 13/110/500 FHA 13/110/750 FHA 13/110/1000
The maximum outer diameter of the work pipe is the highest (mm) 80 80 80 110 110 110
Heating length (mm) 500 750 1000 500 750 1000
Maximum temperature (℃) 1350 1350 1350 1350 1350 1350
External dimensions H x W x d (mm) 420 x 700 x 350 420 x 950 x 350 420 x 1200 x 350 590 x 700 x 520 590 x 950 x 520 590 x 1200 x 520
Weight (KG) 40 50 80 55 70 100
The length of the tube used in the air (mm) 690 940
1190
690
940
1190
The length of the tube used in the atmosphere (mm) 1225
1475
1725
1225 1475
1725
Control cabinet size H x W x d (mm) 500 x 550 x 700 850 x 550 x 700 850 x 550 x 700 850 x 550 x 700 850 x 550 x 700 1100 x 1200 x 700
Control cabinet weight (KG) 60 70 90 70 90 90
Average temperature zone length+-5 ℃ 200 375
500 250 375 500
Power (kW) 5.2
7.8 10.4
7.8
11.5
16.0
Power supply a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e
model FHA 13/110/1250 FHC 13/32/500 FHC 13/50/500 FHC 13/50/750 FHC 13/80/500 FHC 13/80/750
The maximum outer diameter of the work pipe is the highest (mm) 110 32 50 50 80 80
Heating length (mm) 1250 500 500 750 500 750
Maximum temperature (℃) 1350 1350 1350 1350 1350 1350
External dimensions H x W x d (mm) 590 x 1450 x 520 420 x 700 x 350 420 x 700 x 350 420 x 950 x 350 420 x 700 x 350 420 x 950 x 350
Weight (KG) 130 30 35 40 40 50
The length of the tube used in the air (mm) 1440
690
690
940
690
940
The length of the tube used in the atmosphere (mm) 1975
1225
1225 1475
1225 1475
Control cabinet size H x W x d (mm) 1100 x 1200 x 700 500 x 550 x 700 500 x 550 x 700 850 x 550 x 700 500 x 550 x 700 850 x 550 x 700
Control cabinet weight (KG) 90 50 50 60 60 70
Average temperature zone length+-5 ℃ 610 350 350
550 350 550
Power (kW) 20.0
2.4
3.6
5.4 5.2
7.8
Power supply a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e
model FHC 13/80/1000 FHC 13/110/500 FHC 13/110/750 FHC 13/110/1000 FHC 13/110/1250
The maximum outer diameter of the work pipe is the highest (mm) 80 110 110 110 110
Heating length (mm) 1000 500 750 1000 1250
Maximum temperature (℃) 1350 1350
1350 1350 1350
External dimensions H x W x d (mm) 420 x 1200 x 350 590 x 700 x 520 590 x 950 x 520 590 x 1200 x 520 590 x 1450 x 520
Weight (KG) 80 55 70 100 130

The length of the tube used in the air(mm)

1190
690
940
1190
1440
The length of the tube used in the atmosphere (mm) 1725
1225 1475
1725
1975
Control cabinet size H x W x d (mm) 850 x 550 x 700 850 x 550 x 700 850 x 550 x 700 1100 x 1200 x 700 1100 x 1200 x 700
Control cabinet weight (KG) 90 70 90 90 90
Average temperature zone length+-5 ℃ 800 300 500 750 950
Power (kW) 10.4 7.8
11.5
16.0
20.0
Power supply a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e a / b / c / d / e

5、 Attention:

1. When using ceramic working tubes, the heating rate should not exceed 5 ℃/minute

2. The depth of the control cabinet needs to reserve a distance of about 150mm for power plugs and sockets

3. The length of the uniform temperature zone of the horizontal tube furnace is measured when it is 100 ° C below the maximum temperature and shielded plugs are installed at both ends - Power supply: a = 3 phase 380 - 415 V / b = 3 phase 480 V / c = 3 phase 200 - 210 V / d = 3 phase 220 - 240 V / e = 1 phase 220 - 240 V


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!