Carbolite FHA/FHC 1350 ° C tubular furnace
1、 Product Introduction:
Carbolite single zone temperature controlled tube furnace FHA and three zone temperature controlled tube furnace FHC can be used both horizontally and vertically. The maximum temperature is 1300 ° C.
The F series tube furnace has multiple optional accessories. 5mm diameter APM heating wire embedded in ceramic insulation material. Insulation materials have low heat storage, minimal heat loss, and fast heating rate. Using high-quality S-shaped temperature control thermocouples. Up to 8 temperature control zones can be achieved, with precise and uniform temperature control.
2、 Standard parameters:
1. Maximum temperature 1350 ° C
2. 24 segment programmable temperature controller: FHA equipped with EPC3016P1 controller, FHC equipped with CC-T1 controller
3. Over temperature protection
4. The maximum outer diameter of the compatible work tube is 110mm
5. Heating length of 200, 500, 750, 1000 or 1250mm
6. Can be used horizontally or vertically
7. Long service life, stable temperature control
8. High quality S-type temperature control thermocouple
9. Ceramic fiber insulation material with low heat storage capacity
10. The heating element is a high-quality 5mm APM heating wire
11. An independent control cabinet with a 3-meter cable between it and the furnace body, equipped with plugs and sockets
12. Ethernet communication interface
3、 Optional accessories:
1. A series of precision digital controllers with digital communication options, multi-stage programmers and data recorders, as well as digital communication interfaces
2. Various sizes and materials of work tubes are available, such as quartz, ceramic, and metal
3. L-shaped bracket, used vertically
4. Thermal insulation plugs and radiation shielding plugs prevent heat loss and improve temperature uniformity
5. Controllable atmosphere and vacuum components
6. For large-scale work management, please consult us
7. The vacuum system can be equipped with either a mechanical pump or a turbo molecular pump, with a working tube inner diameter of 60mm or more
8. Oxygen probe for inert gas supply system
9. The cable length between the furnace body and the control cabinet is 6 meters
10. Laboratory gas safety system, capable of supplying hydrogen gas above 750 ° C
4、 Technical parameters:
model | FHA 13/32/200 | FHA 13/32/500 | FHA 13/50/200 |
FHA 13/50/500 | FHA 13/50/750 | FHA 13/80/200 |
The maximum outer diameter of the work pipe is the highest (mm) | 32 | 32 | 50 | 50 | 50 | 80 |
Heating length (mm) | 200 | 500 | 200 | 500 | 750 | 200 |
Maximum temperature (℃) | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 |
External dimensions H x W x d (mm) | 420 x 400 x 350 | 420 x 700 x 350 | 420 x 400 x 350 | 420 x 700 x 350 | 420 x 950 x 350 | 420 x 400 x 350 |
Weight (KG) | 25 | 30 | 30 | 35 | 40 | 35 |
The length of the tube used in the air (mm) | 390 | 690 |
390 |
690 | 940 |
390 |
The length of the tube used in the atmosphere (mm) | 925 | 1225 |
925 |
1225 | 1475 |
925 |
Control cabinet size H x W x d (mm) | 500 x 550 x 700 | 500 x 550 x 700 | 500 x 550 x 700 | 500 x 550 x 700 | 850 x 550 x 700 | 500 x 550 x 700 |
Control cabinet weight (KG) | 50 | 50 | 50 | 50 | 60 | 50 |
Average temperature zone length+-5 ℃ | 100 | 250 |
100 | 250 | 375 |
100 |
Power (kW) | 1.2 | 2.4 |
1.5 |
3.6 | 5.4 | 2.1 |
Power supply | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e |
model | FHA 13/80/500 | FHA 13/80/750 | FHA 13/80/1000 | FHA 13/110/500 | FHA 13/110/750 | FHA 13/110/1000 |
The maximum outer diameter of the work pipe is the highest (mm) | 80 | 80 | 80 | 110 | 110 | 110 |
Heating length (mm) | 500 | 750 | 1000 | 500 | 750 | 1000 |
Maximum temperature (℃) | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 |
External dimensions H x W x d (mm) | 420 x 700 x 350 | 420 x 950 x 350 | 420 x 1200 x 350 | 590 x 700 x 520 | 590 x 950 x 520 | 590 x 1200 x 520 |
Weight (KG) | 40 | 50 | 80 | 55 | 70 | 100 |
The length of the tube used in the air (mm) | 690 | 940 |
1190 |
690 |
940 |
1190 |
The length of the tube used in the atmosphere (mm) | 1225 |
1475 |
1725 |
1225 | 1475 |
1725 |
Control cabinet size H x W x d (mm) | 500 x 550 x 700 | 850 x 550 x 700 | 850 x 550 x 700 | 850 x 550 x 700 | 850 x 550 x 700 | 1100 x 1200 x 700 |
Control cabinet weight (KG) | 60 | 70 | 90 | 70 | 90 | 90 |
Average temperature zone length+-5 ℃ | 200 | 375 |
500 | 250 | 375 | 500 |
Power (kW) | 5.2 |
7.8 | 10.4 |
7.8 |
11.5 |
16.0 |
Power supply | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e |
model | FHA 13/110/1250 | FHC 13/32/500 | FHC 13/50/500 | FHC 13/50/750 | FHC 13/80/500 | FHC 13/80/750 |
The maximum outer diameter of the work pipe is the highest (mm) | 110 | 32 | 50 | 50 | 80 | 80 |
Heating length (mm) | 1250 | 500 | 500 | 750 | 500 | 750 |
Maximum temperature (℃) | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 |
External dimensions H x W x d (mm) | 590 x 1450 x 520 | 420 x 700 x 350 | 420 x 700 x 350 | 420 x 950 x 350 | 420 x 700 x 350 | 420 x 950 x 350 |
Weight (KG) | 130 | 30 | 35 | 40 | 40 | 50 |
The length of the tube used in the air (mm) | 1440 |
690 |
690 |
940 |
690 |
940 |
The length of the tube used in the atmosphere (mm) | 1975 |
1225 |
1225 | 1475 |
1225 | 1475 |
Control cabinet size H x W x d (mm) | 1100 x 1200 x 700 | 500 x 550 x 700 | 500 x 550 x 700 | 850 x 550 x 700 | 500 x 550 x 700 | 850 x 550 x 700 |
Control cabinet weight (KG) | 90 | 50 | 50 | 60 | 60 | 70 |
Average temperature zone length+-5 ℃ | 610 | 350 | 350 |
550 | 350 | 550 |
Power (kW) | 20.0 |
2.4 |
3.6 |
5.4 | 5.2 |
7.8 |
Power supply | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e |
model | FHC 13/80/1000 | FHC 13/110/500 | FHC 13/110/750 | FHC 13/110/1000 | FHC 13/110/1250 |
The maximum outer diameter of the work pipe is the highest (mm) | 80 | 110 | 110 | 110 | 110 |
Heating length (mm) | 1000 | 500 | 750 | 1000 | 1250 |
Maximum temperature (℃) | 1350 | 1350 |
1350 | 1350 | 1350 |
External dimensions H x W x d (mm) | 420 x 1200 x 350 | 590 x 700 x 520 | 590 x 950 x 520 | 590 x 1200 x 520 | 590 x 1450 x 520 |
Weight (KG) | 80 | 55 | 70 | 100 | 130 |
The length of the tube used in the air(mm) |
1190 |
690 |
940 |
1190 |
1440 |
The length of the tube used in the atmosphere (mm) | 1725 |
1225 | 1475 |
1725 |
1975 |
Control cabinet size H x W x d (mm) | 850 x 550 x 700 | 850 x 550 x 700 | 850 x 550 x 700 | 1100 x 1200 x 700 | 1100 x 1200 x 700 |
Control cabinet weight (KG) | 90 | 70 | 90 | 90 | 90 |
Average temperature zone length+-5 ℃ | 800 | 300 | 500 | 750 | 950 |
Power (kW) | 10.4 | 7.8 |
11.5 |
16.0 |
20.0 |
Power supply | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e | a / b / c / d / e |
5、 Attention:
1. When using ceramic working tubes, the heating rate should not exceed 5 ℃/minute
2. The depth of the control cabinet needs to reserve a distance of about 150mm for power plugs and sockets
3. The length of the uniform temperature zone of the horizontal tube furnace is measured when it is 100 ° C below the maximum temperature and shielded plugs are installed at both ends - Power supply: a = 3 phase 380 - 415 V / b = 3 phase 480 V / c = 3 phase 200 - 210 V / d = 3 phase 220 - 240 V / e = 1 phase 220 - 240 V