V6-H is a high-performance vector control/torque control frequency converter, with modular software and hardware functions that meet the needs of high-end industries such as lifting, hoisting, papermaking, chemical fiber, elevators, rolling mills, and packaging.
Vector Control 1:
It has excellent performance of vector control and is insensitive to motor parameters.
Starting torque: 0.50Hz 180% rated torque
Speed range: 1:100
Steady speed accuracy: ± 0.5%
0.50Hz can control the motor to operate stably at 150% of its rated torque.
◆ No encoder speed feedback vector control 2:
The precise sensorless vector control technology truly achieves decoupling of AC motors, making the operation control DC motorized.
Starting torque: 0.25Hz 180% rated torque
Speed range: 1:200
Steady speed accuracy: ± 0.2%
0.25Hz can control the motor to operate stably at 150% of its rated torque.
◆ Encoder speed feedback vector control 2:
Starting torque: 0.00Hz 180% rated torque
Speed range: 1:1000
Steady speed accuracy: ± 0.02%
◆ Open loop torque control method:
Independent current loop control achieves true torque control, supporting online switching between torque and speed control.
Torque accuracy: ± 5%
Torque response:<20ms
◆ Closed loop torque control method:
Independent current loop control achieves true torque control, supporting online switching between torque and speed control.
Torque accuracy: ± 5%
Torque response:<10ms
V6-H-4T □□□ G three-phase 400V constant torque/heavy load application
Power (KW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
|
Suitable motor power (KW) | 0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
|
output | Voltage (V) | Three phase 0~rated input voltage | ||||||||||||||
Rated current (A) | 2.5 |
3.8 |
5.5 |
9 |
13 |
17 |
24 |
30 |
39 |
45 |
60 |
75 |
91 |
112 |
150 |
|
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 seconds, with an interval of 10 minutes (inverse time characteristic) | |||||||||||||||
input | Rated voltage/frequency | 3-phase 380V~480V; 50/60Hz | ||||||||||||||
Allowable voltage range | 323~528; Voltage imbalance: ≤ 3%; Allowable frequency fluctuation: ± 5% | |||||||||||||||
Rated current (A) | 3.5 |
6.2 |
9.2 |
14.9 |
21.5 |
27.9 |
39 |
50.3 |
60 |
69.3 |
86 |
104 |
124 |
150 |
201 |
|
BRAKE UNIT | Standard built-in | Built in optional | ||||||||||||||
protection grade | IP20 | |||||||||||||||
Cooling method | Self cooling | Forced air cooling |
Power (KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | .. | .. | .. | .. | .. | |
Suitable motor power (KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ||||||
output | Voltage (V) | Three phase 0~rated input voltage | ||||||||||||||
Rated current (A) | 176 | 210 | 253 | 304 | 377 | 415 | 520 | 585 | 650 | 740 | ||||||
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 seconds, with an interval of 10 minutes (inverse time characteristic) | |||||||||||||||
input | Rated voltage/frequency | 3-phase 380V~480V; 50/60Hz | ||||||||||||||
Allowable voltage range | 323~528; Voltage imbalance: ≤ 3%; Allowable frequency fluctuation: ± 5% | |||||||||||||||
Rated current (A) | 160* | 196* | 232* | 282* | 352* | 385* | 491* | 552* | 624* | 704* | ||||||
BRAKE UNIT | External braking unit required | |||||||||||||||
protection grade | IP20 | |||||||||||||||
Cooling method | Forced air cooling |
*V6-H-4T90G and above product standard external DC reactor
V6-H-4T □□□ L three-phase 400V variable torque/light load application
Power (KW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | |
Suitable motor power (KW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | |
output | Voltage (V) | Three phase 0~rated input voltage | ||||||||||||||
Rated current (A) | 3.3 | 5 | 7.5 | 11 | 17 | 22 | 30 | 36 | 45 | 56 | 72 | 91 | 110 | 142 | 176 | |
Overload capacity | 115% 1 minute, 160% 0.5 seconds, with an interval of 10 minutes (inverse time characteristic) | |||||||||||||||
input | Rated voltage/frequency | 3-phase 380V~480V; 50/60Hz | ||||||||||||||
Allowable voltage range | 323~528; Voltage imbalance: ≤ 3%; Allowable frequency fluctuation: ± 5% | |||||||||||||||
Rated current (A) | 5.6 | 8.1 | 13.5 | 19.5 | 26 | 39 | 50.3 | 60 | 69.3 | 86 | 104 | 124 | 150 | 190 | 235 | |
BRAKE UNIT | Standard built-in | Built in optional | ||||||||||||||
protection grade | IP20 | |||||||||||||||
Cooling method | Self cooling | Forced air cooling |
Power (KW) | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | 450 | .. | .. | .. | .. | .. | |
Suitable motor power (KW) | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | 450 | ||||||
output | Voltage (V) | Three phase 0~rated input voltage | ||||||||||||||
Rated current (A) | 215 | 253 | 304 | 377 | 415 | 520 | 585 | 650 | 740 | 840 | ||||||
Overload capacity | 115% 1 minute, 160% 0.5 seconds, with an interval of 10 minutes (inverse time characteristic) | |||||||||||||||
input | Rated voltage/frequency | 3-phase 380V~480V; 50/60Hz | ||||||||||||||
Allowable voltage range | 323~528; Voltage imbalance: ≤ 3%; Allowable frequency fluctuation: ± 5% | |||||||||||||||
Rated current (A) | 195* | 232* | 282* | 352* | 385* | 491* | 552* | 624* | 704* | 792* | ||||||
BRAKE UNIT | External braking unit required | |||||||||||||||
protection grade | IP20 | |||||||||||||||
Cooling method | Forced air cooling |
*V6-H-4T110L and above product standard external DC reactor