Beecher Instruments MTA-I Manual Tissue Chip Sampling Instrument
Beecher Instruments MTA-I Manual Tissue Chip Sampling Instrument
Product details
United StatesBeecher InstrumentsThe company is one of the earliest professional companies to provide chip manufacturing products,1998yearBeecherThe company was the first to launch the first manual tissue chip sampling instrumentMTA-As soon as it was launched, this instrument has been fully recognized by users for its simple operation, precise positioning, and compact appearance, becoming the most classic instrument necessary for laboratories that make tissue chips.MTA-IThe manual chip sampling instrument can sample hundreds of samples (standard chip capacity can be used for sampling)500A sample)Conveniently built into an organizational chip.
MTA-IManual organization chip sampling instrument

MTA-The sampling instrument mainly includes an operating platform, a punching and sampling device, and a positioning controller. The punching and sampling device can sample the donor tissue wax block and also punch the recipient tissue wax block. The outer diameter of the punching needle is the same as the inner diameter of the sampling needle, and both can be accurately positioned by rotating the knob at the top of the positioning controller. The positioning controller can linearly move the drilling sampling needle forward, backward, left, and right. Its micro display can display the relative or absolute position of the needle in real time (in inches or millimeters), allowing for the preparation of tissue chip wax blocks with identical aperture, spacing, and depth. By using a slicing assistance system to transfer and fix it onto silicified and gelatinized glass slides, it becomes a tissue chip.

The standard configuration is as follows:

A pair of diameters0.6mmThe punching needle

A receptor wax block container

A donor wax block bridge

Detailed operating instructions, including specific guidelines on how to make tissue chips

Additional adjustment pad, suitable for thicker receptor wax blocks

Sample analyzer adjustment tool