BZ-3C5C Mask Bacterial Filtration Efficiency (BEF) Detector
【 Scope of Application 】 Suitable for performance testing of mask bacterial filtration efficiency by metrological verification departments, research i
Product details

[Scope of Application]

Suitable for performance testing of mask bacterial filtration efficiency by metrological verification departments, research institutes, mask production enterprises, and other relevant departments.

Execution standards

YY 0469-2011 Technical Requirements for Medical Surgical Masks Appendix B Bacterial Filtration Efficiency (BFE)

YY/T 0969-2013 Disposable Medical Masks

ASTMF2100、ASTMF2101、EN14683

Q/0212 ZRB003-2011 Bacterial Filtration Efficiency (BFE) Tester for Medical Surgical Masks

Technical parameters:

1Adopting a dual gas path simultaneous comparative sampling method has improved the accuracy of sampling.
2Negative pressure experimental system to ensure the safety of operators; The negative pressure cabinet is equipped with a peristaltic pump,A. Bilibili Level 6 Anderson; The flow rate of the peristaltic pump can be set;

3The flow rate of special microbial aerosol generator at night can be set, and the atomization effect is good; Embedded high-speed industrial microcomputer control;

410.4-inch industrial grade high brightness color touch display screen; USB interface, supporting USB data transfer and storage;

5The cabinet is equipped with high brightness lighting fixtures; Built in leakage protection switch to protect the safety of operators;

6The inner layer of the cabinet is made of stainless steel and processed as a whole, while the outer layer is made of spray coated cold-rolled sheet. The insulation and flame retardant properties are maintained between the inner and outer layers;

Front switch glass door, convenient for experimental personnel to observe and operate;
7Detachable bracket with adjustable height; Dual purpose casters for support and mobility.

TECHNICAL INDEX

Parameters

Parameter range

resolution

maximum permissible error

A-channel sampling flow

28.3L/min

0.1L/min

Better than ± 2.5%

B sampling flow rate

28.3L/min

0.1L/min

Better than ± 2.5%

Spray flow

(8~10)L/min

0.1L/min

Better than ± 5.0%

Peristaltic pump flow rate

(0.006~3.0)mL/min

0.001ml/min

Better than ± 2.5%

Pressure in front of A flow meter

(-20~0)kPa

0.01kPa

Better than ± 2.5%

Pressure in front of B-channel flowmeter

(-20~0)kPa

0.01kPa

Better than ± 2.5%

Front pressure of spray flowmeter

(0~300)kPa

0.1kPa

Better than ± 2.5%

Negative pressure in the aerosol chamber

(-90~-120)Pa

0.1Pa

Better than ± 2.0%

operation temperature

0~50

Cabinet negative pressure

(-50~-200)Pa

Data storage capability

>100000 sets

Characteristics of high-efficiency air filter

The filtration efficiency for particles above 0.3um is ≥ 99.99%

Mass median diameter of aerosol generator

Average particle diameter (3.0 ± 0.3) μ m, geometric standard deviation ≤ 1.5

Dual channel 6-stage Anderson sampler captures particle size

Grade I>7 μ m, Grade II (4.7-7) μ m, Grade III (3.3-4.7) μ m,

Grade IV (2.1-3.3) μ m, Grade V (1.1-2.1) μ m,

Grade VI (0.6-1.1) μ m

Total number of particles in the positive quality control sampler

(2200±500)cfu

Ventilation flow rate of negative pressure cabinet

≥5m3/min

Bracket size

Height adjustable within 100mm

Working power supply

AC220V±10%,50Hz

Instrument noise

<65dB(A)

Overall Power Consumption

<1500W


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content