English

Shanghai Fuzhan Environmental Protection Technology Co., Ltd
Home>Products>BNC1680 Multi point Monitoring and Alarm Controller
BNC1680 Multi point Monitoring and Alarm Controller
The BNC1680 multi-point monitoring and alarm controller, also known as a controller, gas detector host, display controller, alarm host, etc., is used
Product details

Detailed information of BNC1680 multi-point monitoring alarm controller:

BNC1680Multi point monitoring and alarm controller

Product Introduction

BNC1680Multi point monitoring and alarm controller, also known as controller, gas detector host, display controller, alarm host, etc., is used to detect the content of flammable gases or liquid vapors in the air within the lower explosive limit. It can be equipped with multiple detection probes and centrally control multiple points. This system uses a microprocessor as the control unit, which has high sensitivity and fast response speed. When the concentration of flammable gases in the environment reaches or exceeds the preset alarm value, the controller immediately issues an audible and visual alarm and drives exhaust or other peripheral devices to prevent explosions and fires, thereby ensuring life. This system can be widely used in factories, oil depots, liquefied gas stations, gas stations, gas stations, paint spraying rooms and other places that require fire and explosion prevention for safety detection and alarm.

Product Features
Measurement range:% LEL,% VOL, PPM
Accuracy: ±5%F. S;
Sensor model: 4-20mAOr RS485
Alarm point: two-level alarm, can be freely set by the user
Preset value: (EX) Low report: 20% LEL High report: 50% LEL
Instruction method:digitalDisplay concentration data
Output mode: switch quantity MAX 3.0A
Working method: on-site fixed installation, wall mounted
Networking capacity: 4 channels and 8 channelsBus 32 channels 99 channels
Natural diffusion, continuous operation
Working environment: Temperature -20-50Humidity<95% RH
Working voltage: AC220V ± 10% 50HZ
Power: Monitor Max 6W Sensor Max 1W

Execution standard: GB16808-2008
Requirements for the connection line between the system and external (gas) detectors:
standardbranch line3-wire connection method,3 piecesSingle core wire diameter ≥ 1.5mm, wire length ≤ 1000m.
standardLine 4Wire system connection method,4 piecesSingle core wire diameter ≥ 1.5mm, wire length ≤ 1000m.