Shanghai Huanao Technology Co., Ltd
Home>Products>BINDER FDL115 safety drying oven
BINDER FDL115 safety drying oven
BINDER FDL115 safety drying oven
Product details

BINDER FDL115 safety drying oven

1、 Product Introduction:

1. Temperature range: ambient temperature plus 5 ℃ to 300 ℃

2 APT.lineTMPreheating chamber technology

3. Controller using interval programming and real-time programming

4. 2 chrome plated sockets

5. Fresh air monitoring and heating automatic disconnection device using sound and optical alarms

6. Replaceable fresh air filter element, M6 grade

7. Independent adjustable temperature safety device level 2 (DIN 12880) with optical alarm

8. Computer interface: RS 422

2、 Technical parameters:

PRODUCT MODEL FDL115-230V1
Choose a model standard
Item code 9010-0292
measure
Internal volume [L] 115
Net weight of equipment (unloaded) [kg] 90
Maximum total load [kg] 60
Maximum load per partition [kg] 30
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 830
Net weight at height [mm] 805
Depth net weight [mm] 685
Wall distance from rear [mm] 160
Wall to side distance [mm] 100
Internal dimensions
Width [mm] 600
Height [mm] 435
Depth [mm] 435
Data related to the environment
Energy consumption at 150 ℃ [Wh/h] 1200
Sound pressure level [dB (A)] 57
firmware
Number of partitions (hours/maximum) 2/5
Temperature performance data
The temperature range exceeds the indoor temperature by 10 ℃ to [℃] 300
Temperature deviation is 150 ℃ [± K] 2.5
Temperature fluctuation [± K] 0.8
Heating time to 150 ℃ [min] 20
The recovery time after opening the door in 30 seconds is 150 ℃ [min] 12
Ventilation data
Air circulation (approximate) [x/min] 20
Exhaust volume in accordance with EN 1539 standard at a temperature of 50 ℃ [ca. L/min] 400
Solvent quantity
Maximum allowable solvent amount (M-100 g/mol, U-40 g/m3, K=0.5 at -180 ℃) [g] 6.65
Electric data
Rated voltage [V] 230
Power frequency [Hz] 50/60
Rated power [kW] 2.9
Phase (rated voltage) 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.