BINDER FDL115 safety drying oven
1、 Product Introduction:
1. Temperature range: ambient temperature plus 5 ℃ to 300 ℃
2 APT.lineTMPreheating chamber technology
3. Controller using interval programming and real-time programming
4. 2 chrome plated sockets
5. Fresh air monitoring and heating automatic disconnection device using sound and optical alarms
6. Replaceable fresh air filter element, M6 grade
7. Independent adjustable temperature safety device level 2 (DIN 12880) with optical alarm
8. Computer interface: RS 422
2、 Technical parameters:
PRODUCT MODEL | FDL115-230V1 |
Choose a model | standard |
Item code | 9010-0292 |
measure | |
Internal volume [L] | 115 |
Net weight of equipment (unloaded) [kg] | 90 |
Maximum total load [kg] | 60 |
Maximum load per partition [kg] | 30 |
The dimensions of the casing do not include additional components and connectors | |
Net weight width [mm] | 830 |
Net weight at height [mm] | 805 |
Depth net weight [mm] | 685 |
Wall distance from rear [mm] | 160 |
Wall to side distance [mm] | 100 |
Internal dimensions | |
Width [mm] | 600 |
Height [mm] | 435 |
Depth [mm] | 435 |
Data related to the environment | |
Energy consumption at 150 ℃ [Wh/h] | 1200 |
Sound pressure level [dB (A)] | 57 |
firmware | |
Number of partitions (hours/maximum) | 2/5 |
Temperature performance data | |
The temperature range exceeds the indoor temperature by 10 ℃ to [℃] | 300 |
Temperature deviation is 150 ℃ [± K] | 2.5 |
Temperature fluctuation [± K] | 0.8 |
Heating time to 150 ℃ [min] | 20 |
The recovery time after opening the door in 30 seconds is 150 ℃ [min] | 12 |
Ventilation data | |
Air circulation (approximate) [x/min] | 20 |
Exhaust volume in accordance with EN 1539 standard at a temperature of 50 ℃ [ca. L/min] | 400 |
Solvent quantity | |
Maximum allowable solvent amount (M-100 g/mol, U-40 g/m3, K=0.5 at -180 ℃) [g] | 6.65 |
Electric data | |
Rated voltage [V] | 230 |
Power frequency [Hz] | 50/60 |
Rated power [kW] | 2.9 |
Phase (rated voltage) | 1~ |
1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.