Shenzhen Wanyi Technology Co., Ltd
Home>Products>Atmospheric Environment Freshness Index Monitoring System
Atmospheric Environment Freshness Index Monitoring System
The PMION-1000 Meteorological and Forestry Air Freshness Index Monitoring System (Ozone, Negative Ions, Meteorological Parameters) is developed by She
Product details


System Introduction

PMION-1000The Type Air Freshness Index Monitoring System is developed by Shenzhen Wanyi Technology Co., Ltd. to monitor the ecological environmentThe work idea of "unified evaluation standards, unified monitoring methods, unified distribution standards, and unified technical improvement" is to carry out fresh air monitoring and network system construction, guide green development and consumption, further improve environmental air quality, and create a better ecological environment. We will jointly develop an online monitoring device for monitoring various factors of environmental air.

The equipment monitoring method complies with the "Technical Specification for Installation and Acceptance of Continuous Automatic Monitoring System for Environmental Air Particulate Matter" and the "Technical Specification for Installation and Acceptance of Continuous Automatic Monitoring System for Environmental Air Gaseous Pollutants".

• Application scope

PMION-1000The Type Air Freshness Index Monitoring System is an ecological environment measurement device used to measure negative oxygen ions in the atmospheric environmentPM2.5Ozone, meteorological and other parameters are designed for long-term online monitoring and uploaded to the Freshness Index platform. Widely used in:

1Environmental protection, forestry, meteorology, tourism and other departments

2Monitoring of administrative area stations

3Meteorological monitoring, urban stations

4Ecotourism monitoring

5Monitoring of nature reserves, forest parks, wetlands, etc

• Technical indicators

Measurement parameters

measuring range

resolution

accuracy

measuring principle

ozone

0.0-1000ppb

0.1ppb

±1%F.S.

UV absorption method (national standard)

PM2.5

0-1000ug/m3

0.01ug/m3

±2.5%

Beta Ray Method (National Standard)

(Positive) negative oxygen ions

0-500Ten thousand/cm3

1individual/m3

be better than±10%

Double cylinder cross conductivity resistance method

Optional parameters

Meteorological five parameters, illuminance, ultraviolet intensity, nuclear radiation, etc.

transmission

RS232GPRS

display

7Inch touch controlLCD.

Usage environment

-3050℃, 0-95% RH without condensation. Built in air conditioning and dehumidification system.