Armored platinum resistance thermometers are matched with display instruments to automatically detect the surface temperature of gases, liquid media,
Product details

Armored platinum resistance thermometers are matched with display instruments to automatically detect the surface temperature of gases, liquid media, or solids within the temperature range of -200 to 600 ℃. Suitable for installation in narrow pipelines and special occasions that require rapid response and miniaturization.

Armored platinum resistance thermometers are usually composed of main components such as temperature sensing elements, installation and fixing devices, and wiring devices.

Armored platinum thermistor has the advantages of slender shape, fast thermal response, vibration resistance, and long service life.

Model specifications


WZPKArmored platinum thermistor

WZPK - □ 0 □ type*

Non wired box armored platinum thermistor

WZPK - □ 0 □ type*

Imitation of West German type wireless box armored platinum thermistor (specify "Imitation of West German type" when ordering)

WZPK - □ 0 □ 3 type

Simple armored platinum thermistor

WZPK - □ 2 □ type

Anti splash junction box armored platinum thermistor

WZPK - □ 3 □ type

Waterproof junction box armored platinum thermistor

WZPK - □ 4 □ type

Explosion proof junction box armored platinum thermistor

WZPK - □ 5 □ type

D-type waterproof junction box armored platinum thermistor

WZPK - □ 6 □ type

Socket type armored platinum thermistor

1

Number of platinum resistance elements

1

Single support type (d=φ 3- φ 8mm)

2

Double support type (d=φ 5- φ 8mm)

2

Install fixed devices

1

No fixed installation (not applicable to explosion-proof type)

2

Fixed card sleeve thread

3

Movable card sleeve thread (not applicable to explosion-proof type)

4

Fixed card sleeve flange

5

Movable card sleeve flange (not applicable to explosion-proof type)

3

Type of junction box

0

No junction box

2

Splash proof junction box

3

Waterproof junction box

4

Explosion proof junction box

5

D-type waterproof junction box

6

Socket type junction box

4

Measurement end type

3

Three-wire

4

Four wire system **

5

Lead type

GVV

General lead (WZPK - □ 0 □ 3 type)

HBS

Heat resistant lead wire (WZPK - □ 0 □ 3 type)

6

Lead length S

Mm (when not labeled, S=150mm)

7

Temperature range for use

L

-200~100℃

M

0~350℃

H

0~600℃

8

Graduation

10

Pt10 *

100

Pt100

9

Tolerance level

A

A-class tolerance: ± (0.15+0.2% | t |)*

B

B-level tolerance: ± (0.3+0.5% | t |)

10

Total length L

mm

11

Casing diameter

E

φ3.0

F

φ4.0

J

φ4.5

H

φ5.0

J

φ6.0

k

φ8.0

12

Insertion length l

mm

13

Material of casing

A

1Cr18Ni9Ti

14

Explosion proof level

BT4

dⅡBT4

CT1~6

dⅡCT1~6

15

`Additional device`

Please refer to the sample of armored thermocouple standard parts

WZGPK armored platinum thermistor (non junction box)

WZGPK-1 □ type

Basic armored platinum thermistor

WZGPK-1 □ 1 type

Lead wire type armored platinum thermistor

WZGPK-1 □ 2 type

Lead sleeve snake skin tube connector type armored platinum thermistor

WZGPK-1 □ 3 type

Armored platinum thermistor with lead socket

WZGPK-1 □ 4 type

Snake skin tube socket type armored platinum thermistor with lead sleeve

WZGPK-6 □ Type A

Socket type armored platinum thermistor

1

Number of platinum resistance elements

1

Single support type (d=φ 3- φ 8mm)

2

Double support type (d=φ 5- φ 8mm)

2

Measurement end type

3

Three-wire

4

Four wire system*

3

Lead type

GVV

General purpose leads (WZGPK-1 □ type, WZGPK-6 □ A type none)

HBS

Heat resistant leads (WZGPK-1 □ type, WZGPK-6 □ A type none)

4

Lead length S

Mm (S=150mm when not marked)

5

Temperature range for use

L

M

N

-200~100℃

0~350℃

0~600℃

6

Graduation

10

100

Pt10

Pt100

7

Tolerance level

A

A-class tolerance: ±(0.15+0.2%|t|)*

B

B-level tolerance: ± (0.3+0.5% | t |)

8

Total length L

mm

9

Sleeve diameter mm

E

φ3.0

F

φ4.0

G

φ4.5

H

φ5.0

J

φ6.0

K

φ8.0

10

Insertion depth

mm

11

Material of casing

A

1Cr18Ni9Ti

12

`Additional device`

Please refer to the sample of armored thermocouple standard parts

WZGPK armored platinum thermistor (junction box)

WZGPK

Armored platinum thermistor (junction box)

1

Number of platinum resistance elements

1

Single support type (d=φ 3- φ 8mm)

2

Double support type (d=φ 5- φ 8mm)

2

Type of junction box

2

Splash proof junction box

3

Waterproof junction box

4

Explosion proof junction box

5

Waterproof spring pressed junction box

7

Explosion proof spring pressed junction box

3

Measurement end type

3

Three-wire

,

4

Four wire system*

4

structure characteristics

No additional devices

S

Reinforced tube type

SB

Fixed bolt type with reinforcing tube (with corrugated tube seal) (only applicable to WZGPK-5 port □□□ port, 7-port port type)

G

Sealed bolt type with reinforced pipe

N

Pipe joint type

NH

Pipe joint (welded type) (only applicable to WZGPK-5 port □, 7 □□ type)

NB

With pipe joint (with corrugated pipe seal)

U

Equipped with a flexible connector

UH

Equipped with a flexible joint (welded type)

UB

Equipped with a flexible joint (sealed with corrugated pipe)

W

Integrated drilling protection tube type

WH

Protective tube with steel pipe

5

Temperature range for use

L

-200~100℃

M

0~350℃

H

0~600℃

6

Graduation

10

Pt10 *

100

Pt100

7

Tolerance level

A

A-class tolerance ± (0.15+0.2% | t |)*

B

B-level tolerance ± (0.3+0.5% | t |)

8

Total length L

mm

9

Casing diameter

E

φ3.0

F

φ4.0

G

φ4.5

H

φ5.0

J

φ6.0

K

φ8.0

10

Insertion depth l

mm

11

Material of casing`

A

1Cr18Ni9Ti

12

Bolt specification

M1(ZG1)

M20×1.5(ZG1/2″)

M2(ZG2)

M27×2(ZG3/4″)

G1

G1/2″

G2

G3/4″

13

Outer diameter of protective tube

12

φ12

16

φ16

20

φ20

14

Explosion proof level

BT4

dⅡBT4

CT1~6

dⅡCT~6

15

`Additional device`

Please refer to the sample of armored thermocouple standard parts



Online inquiry