Armored platinum resistance thermometers are matched with display instruments to automatically detect the surface temperature of gases, liquid media, or solids within the temperature range of -200 to 600 ℃. Suitable for installation in narrow pipelines and special occasions that require rapid response and miniaturization.
Armored platinum resistance thermometers are usually composed of main components such as temperature sensing elements, installation and fixing devices, and wiring devices.
Armored platinum thermistor has the advantages of slender shape, fast thermal response, vibration resistance, and long service life.
Model specifications
WZPKArmored platinum thermistor
WZPK - □ 0 □ type* |
Non wired box armored platinum thermistor |
||
WZPK - □ 0 □ type* |
Imitation of West German type wireless box armored platinum thermistor (specify "Imitation of West German type" when ordering) |
||
WZPK - □ 0 □ 3 type |
Simple armored platinum thermistor |
||
WZPK - □ 2 □ type |
Anti splash junction box armored platinum thermistor |
||
WZPK - □ 3 □ type |
Waterproof junction box armored platinum thermistor |
||
WZPK - □ 4 □ type |
Explosion proof junction box armored platinum thermistor |
||
WZPK - □ 5 □ type |
D-type waterproof junction box armored platinum thermistor |
||
WZPK - □ 6 □ type |
Socket type armored platinum thermistor |
||
1 |
Number of platinum resistance elements |
1 |
Single support type (d=φ 3- φ 8mm) |
2 |
Double support type (d=φ 5- φ 8mm) |
||
2 |
Install fixed devices |
1 |
No fixed installation (not applicable to explosion-proof type) |
2 |
Fixed card sleeve thread |
||
3 |
Movable card sleeve thread (not applicable to explosion-proof type) |
||
4 |
Fixed card sleeve flange |
||
5 |
Movable card sleeve flange (not applicable to explosion-proof type) |
||
3 |
Type of junction box |
0 |
No junction box |
2 |
Splash proof junction box |
||
3 |
Waterproof junction box |
||
4 |
Explosion proof junction box |
||
5 |
D-type waterproof junction box |
||
6 |
Socket type junction box |
||
4 |
Measurement end type |
3 |
Three-wire |
4 |
Four wire system ** |
||
5 |
Lead type |
GVV |
General lead (WZPK - □ 0 □ 3 type) |
HBS |
Heat resistant lead wire (WZPK - □ 0 □ 3 type) |
||
6 |
Lead length S |
Mm (when not labeled, S=150mm) |
|
7 |
Temperature range for use |
L |
-200~100℃ |
M |
0~350℃ |
||
H |
0~600℃ |
||
8 |
Graduation |
10 |
Pt10 * |
100 |
Pt100 |
||
9 |
Tolerance level |
A |
A-class tolerance: ± (0.15+0.2% | t |)* |
B |
B-level tolerance: ± (0.3+0.5% | t |) |
||
10 |
Total length L |
mm |
|
11 |
Casing diameter |
E |
φ3.0 |
F |
φ4.0 |
||
J |
φ4.5 |
||
H |
φ5.0 |
||
J |
φ6.0 |
||
k |
φ8.0 |
||
12 |
Insertion length l |
mm |
|
13 |
Material of casing |
A |
1Cr18Ni9Ti |
14 |
Explosion proof level |
BT4 |
dⅡBT4 |
CT1~6 |
dⅡCT1~6 |
||
15 |
`Additional device` |
Please refer to the sample of armored thermocouple standard parts |
WZGPK armored platinum thermistor (non junction box)
WZGPK-1 □ type |
Basic armored platinum thermistor |
||
WZGPK-1 □ 1 type |
Lead wire type armored platinum thermistor |
||
WZGPK-1 □ 2 type |
Lead sleeve snake skin tube connector type armored platinum thermistor |
||
WZGPK-1 □ 3 type |
Armored platinum thermistor with lead socket |
||
WZGPK-1 □ 4 type |
Snake skin tube socket type armored platinum thermistor with lead sleeve |
||
WZGPK-6 □ Type A |
Socket type armored platinum thermistor |
||
1 |
Number of platinum resistance elements |
1 |
Single support type (d=φ 3- φ 8mm) |
2 |
Double support type (d=φ 5- φ 8mm) |
||
2 |
Measurement end type |
3 |
Three-wire |
4 |
Four wire system* |
||
3 |
Lead type |
GVV |
General purpose leads (WZGPK-1 □ type, WZGPK-6 □ A type none) |
HBS |
Heat resistant leads (WZGPK-1 □ type, WZGPK-6 □ A type none) |
||
4 |
Lead length S |
Mm (S=150mm when not marked) |
|
5 |
Temperature range for use |
L M N |
-200~100℃ |
0~350℃ | |||
0~600℃ | |||
6 |
Graduation |
10 100 |
Pt10 |
Pt100 | |||
7 |
Tolerance level |
A |
A-class tolerance: ±(0.15+0.2%|t|)* |
B |
B-level tolerance: ± (0.3+0.5% | t |) |
||
8 |
Total length L |
mm |
|
9 |
Sleeve diameter mm |
E |
φ3.0 |
F |
φ4.0 |
||
G |
φ4.5 |
||
H |
φ5.0 |
||
J |
φ6.0 |
||
K |
φ8.0 |
||
10 |
Insertion depth |
mm |
|
11 |
Material of casing |
A |
1Cr18Ni9Ti |
12 |
`Additional device` |
Please refer to the sample of armored thermocouple standard parts |
WZGPK armored platinum thermistor (junction box)
WZGPK |
Armored platinum thermistor (junction box) |
|||||
1 |
Number of platinum resistance elements |
1 |
Single support type (d=φ 3- φ 8mm) |
|||
2 |
Double support type (d=φ 5- φ 8mm) |
|||||
2 |
Type of junction box |
2 |
Splash proof junction box |
|||
3 |
Waterproof junction box |
|||||
4 |
Explosion proof junction box |
|||||
5 |
Waterproof spring pressed junction box |
|||||
7 |
Explosion proof spring pressed junction box |
|||||
3 |
Measurement end type |
3 |
Three-wire |
|||
, 4 |
Four wire system* |
|||||
4 |
structure characteristics |
|
No additional devices |
|||
S |
Reinforced tube type |
|||||
SB |
Fixed bolt type with reinforcing tube (with corrugated tube seal) (only applicable to WZGPK-5 port □□□ port, 7-port port type) |
|||||
G |
Sealed bolt type with reinforced pipe |
|||||
N |
Pipe joint type |
|||||
NH |
Pipe joint (welded type) (only applicable to WZGPK-5 port □, 7 □□ type) |
|||||
NB |
With pipe joint (with corrugated pipe seal) |
|||||
U |
Equipped with a flexible connector |
|||||
UH |
Equipped with a flexible joint (welded type) |
|||||
UB |
Equipped with a flexible joint (sealed with corrugated pipe) |
|||||
W |
Integrated drilling protection tube type |
|||||
WH |
Protective tube with steel pipe |
|||||
5 |
Temperature range for use |
L |
-200~100℃ |
|||
M |
0~350℃ |
|||||
H |
0~600℃ |
|||||
6 |
Graduation |
10 |
Pt10 * |
|||
100 |
Pt100 |
|||||
7 |
Tolerance level |
A |
A-class tolerance ± (0.15+0.2% | t |)* |
|||
B |
B-level tolerance ± (0.3+0.5% | t |) |
|||||
8 |
Total length L |
mm |
||||
9 |
Casing diameter |
E |
φ3.0 |
|||
F |
φ4.0 |
|||||
G |
φ4.5 |
|||||
H |
φ5.0 |
|||||
J |
φ6.0 |
|||||
K |
φ8.0 |
|||||
10 |
Insertion depth l |
mm |
||||
11 |
Material of casing` |
A |
1Cr18Ni9Ti |
|||
12 |
Bolt specification |
M1(ZG1) |
M20×1.5(ZG1/2″) |
|||
M2(ZG2) |
M27×2(ZG3/4″) |
|||||
G1 |
G1/2″ |
|||||
G2 |
G3/4″ |
|||||
13 |
Outer diameter of protective tube |
12 |
φ12 |
|||
16 |
φ16 |
|||||
20 |
φ20 |
|||||
14 |
Explosion proof level |
BT4 |
dⅡBT4 |
|||
CT1~6 |
dⅡCT~6 |
|||||
15 |
`Additional device` |
Please refer to the sample of armored thermocouple standard parts |