Analysis of Ethyl Acetate Content by Gas Chromatography
Product introduction Ethyl acetate content analysis gas chromatograph is a practical chromatograph developed by Tengzhou Zhongke Spectrum for enterpri
Product details
brand ZKP/Zhongkepu

Analysis principle of ethyl acetate: using gas chromatography with thermal conductivity detector and area normalization method for quantitative calculation of results

Analyze configuration sheet

instrument GC-2010 gas chromatograph thermal conductivity detector+filling tube injection system 1 unit
chromatographic column Stainless steel filled column 1 unit
data processing Chromatography workstation 1 set
External air source Air, nitrogen, hydrogen gas cylinders or generators 1 set
computer Brand computer XP system 1 unit







Typical chromatogram of ethyl acetate:

Characteristics of GC-2010 gas chromatograph

1Adopting320 x 240dot matrix5.7An inch large screen LCD Chinese display, real-time display of various temperatures and operating conditions, clear and intuitive content, truly realizing human-machine dialogue;
2Power on self-test, wide range self diagnostic function, can accurately determine the fault location and alarm;
3Six independent temperature controls (vaporization chamber and capillary vaporization chamber can be independently controlled), Five level program heating function;
4Overtemperature Protection function: If any circuit exceeds the set temperature, the instrument will automatically power off and sound an alarm;
5The vertical heating device of * makes sample vaporization more reliable, reduces the heat radiation generated in the vaporization chamber to the minimum, and ensures minimal temperature deviation inside the column box;
6Intelligent fuzzy control rear door opening system, automatically tracks temperature and dynamically adjusts The angle of the air door can achieve precise temperature control even near room temperature;
7Configure filling column head injection, glass lining injection, with diaphragm cleaning Functional capillary diversion/Non split injection device and capable of installing gas injectors;
8High precision dual stable gas path, capable of installing four types of detectors simultaneously;
9
Optional electronic flow pressure display system with built-in workstation device.
Temperature control indicators
1.Temperature control range: room temperature 5400 increment0.1
2.Temperature control accuracy: superior to±0.01
Program heating: Five step interval constant temperature time0999minincrement0.1minTemperature increment0.1
Heating rate:200The biggest one below40/min 200Up to the biggest20/min

Note: Dimensions: 660 * 460465mm machine weight: 60kg input power supply: AC 220V ± 10% 50HZ 2KW

Zhongkepu's main products: gas chromatograph,Liquid chromatograph,Liquefied gas analyzer,Baijiu chromatograph,Transformer oil spectrophotometer,Solvent Residual Chromatography Analyzer,Pesticide residue analyzer,Natural gas analyzer,Dimethyl ether detector,Gas chromatography consumables,Nitrogen hydrogen air generator,Packed Column,liquid chromatographic column,Chromatographic accessories,Gas chromatography valve,Headspace bottle,gas-purifier,Deoxygenation tube,Capping pliers,Gasification pad,Micro injector,capillary/Fill the column stone ink padFlat gas injection six way valve
Purchase gas chromatograph|Inquiry for gas chromatograph|Purchase 3-mercaptopropionic acid analytical gas chromatograph

Procurement www.gcsepu.com


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!