Tengzhou Zhongke Spectral Analysis Instrument Co., Ltd
Home>Products>Analysis of DEET content in mosquito repellent by gas chromatography
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18663278921
  • Address
    No. 20, Xibeitan, Tengzhou City, Shandong Province
Contact Now
Analysis of DEET content in mosquito repellent by gas chromatography
Product Introduction: Use a gas chromatograph to analyze the DEET content of mosquito repellent, and measure the DEET content of mosquito repellent wi
Product details
brand ZKP/Zhongkepu

Tengzhou Zhongkepu Priority Recommended Product - Mosquito Repellent DEET Content Analysis Gas Chromatography

Product IntroductionanophelifugeDEETThe chemical name isN. N-diethyl-3-methylbenzamide

DEET not only has strong and long-lasting mosquito repellent effects that are not affected by geography, but also is non-toxic, odorless, and safe to use. It also has a broad-spectrum characteristic and has a repellent effect on other pest species. Tengzhou Zhongkepu used DEET content analysis of mosquito repellent and determined the mosquito repellent by gas chromatography with dibutyl phthalate as the internal standardDEETThe content can be separated and determined within 10 minutes under the selected chromatographic conditions, with fast speed and good separation effect, and the determination results are satisfactory

Analysis chart of DEET standard sample of mosquito repellent

Instrument configuration and reagents

Product Name

to configure

quantity

Gas chromatograph host

GC-2020Equipped with a hydrogen flame detector+Capillary injection port

1platform

data processing

Chromatography workstation

1set

Chromatographic column 0.53mm * 25m * 1.0um large caliber capillary column 1 piece

External air source

Nitrogen hydrogen air cylinder or generator

1set

computer

Brand computerxpsystem

1platform








Performance characteristics of GC-2020 gas chromatograph

1. Adopting320 x 240lattice5.7An inch large screen LCD Chinese display, real-time display of various temperatures and operating conditions, clear and intuitive content, truly realizing human-machine dialogue;
2Power on self-test, wide range self diagnostic function, can accurately determine the fault location and alarm;
3Six independent temperature controls (vaporization chamber and capillary vaporization chamber can be independently controlled), Five level program heating function;
4Overtemperature Protection function: If any circuit exceeds the set temperature, the instrument will automatically power off and sound an alarm;
5The vertical heating device of * makes sample vaporization more reliable, reduces the heat radiation generated in the vaporization chamber to the minimum, and ensures minimal temperature deviation inside the column box;
6Intelligent fuzzy control rear door opening system, automatically tracks temperature and dynamically adjusts The angle of the air door can achieve precise temperature control even near room temperature;
7Configure filling column head injection, glass lining injection, with diaphragm cleaning Functional capillary diversion/Non split injection device and capable of installing gas injectors;
8High precision dual stable gas path, capable of installing four types of detectors simultaneously;
9
Optional electronic flow pressure display system with built-in workstation device.

Temperature control indicators
1.Temperature control range: room temperature 5400 increment0.1
2.Temperature control accuracy: superior to±0.01

Program heating: Five step interval constant temperature time0999minincrement0.1minTemperature increment0.1
Heating rate:200Greatest at ℃40/min 200Up to the biggest20/min


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!