In most integrated weather stations, the measurement of total solar radiation and precipitation can only be chosen between the two. ATMOS 41 can simultaneously monitor these two parameters.
The ATMOS 41 integrated weather station can seamlessly collaborate with ZENTRA ZL (6-channel) data acquisition, plug and play, and can store and manage data based on cloud servers. The entire process does not involve wiring or programming.
At present, the sensors in most weather stations are independent, and the installation and maintenance costs are relatively high. Wiring and programming deter many people; And on a weather station stand, determining the optimal placement for all sensors is also a matter that requires careful consideration.
The traditional integrated meteorological station solves the above problems. However, in this observation system, if one or more additional sensors are to be added, such as for measuring soil profile moisture content, additional data collection is usually required.
1+Multi Solution
METER's solution is”1 (Integrated)+Multiple (Multiple Independent Sensors)”The data from the ATMOS 41 integrated weather station is transmitted through one cable. This means that when measuring meteorological parameters, only one channel of data acquisition needs to be occupied. Therefore, if ATMOS 41 and ZENTRA ZL (6-channel) data acquisition are connected, more METER sensors can be added, such as soil moisture sensors.
function characteristics
Multiple meteorological variables can be measured, including air temperature, relative humidity, vapor pressure, atmospheric pressure, wind speed, extreme wind speed, wind direction, total solar radiation, precipitation, lightning frequency and distance
Easy installation
No movable components
All data is transmitted through only one cable
SDI-12 Digital Communication
Collecting and managing data through ZENTRA
configuration parameter
range |
resolution |
accuracy |
|
Total solar radiation |
0 ~ 1750 W/m2 |
1 W/m2 |
±5% |
precipitation |
0 ~ 400 mm/hr |
0.017 mm |
The measured values±5%@0 ~ 50 mm/hr |
vapor pressure |
0 ~ 47 kPa |
0.01 kPa |
typical±0.2 kPa @ below 40 ℃ |
relative humidity |
0 ~ 100% |
0.1% |
Typical 3% |
air temperature |
-50 ~ 60℃ |
0.1℃ |
±0.6℃ |
Temperature measured by humidity sensor |
-40 ~ 50℃ |
0.1℃ |
±1.0℃ |
atmospheric pressure |
50 ~ 110 kPa |
0.01 kPa |
±0.1 kPa |
horizontal wind speed |
0 ~ 30 m/s |
0.01 m/s |
Greater than 0.3 m/s or 3% of the measured value |
Extreme wind speed |
0 ~ 30 m/s |
0.01 m/s |
Greater than 0.3 m/s or 3% of the measured value |
wind direction |
0 ~ 359° |
1° |
±5° |
Sensor inclination angle |
0 ~ 180° |
0.1° |
±1° |
Lightning counter |
0 ~ 65535 |
Once |
Typical>25% @ within 10 km |
Lightning distance |
0 ~ 40 km |
3 km |
|