ATDS-30S Dual Channel Fully Automatic Secondary Thermal Desorption Instrument
Product Introduction: The ATDS-30S dual channel fully automatic thermal desorption instrument is a new generation of fully automatic thermal desorptio
Product details

ATDS-30StypeDual channelFully automatic thermal desorption instrument(Second time)

1Instrument Introduction

ATDS-30StypeDual channelThe fully automatic thermal desorption instrument isBeijing Zhongyi Yusheng Technology Co., Ltd. has developed and launched a dual function system with fully automated design, touch screen display, and more convenient operation for continuous operation3A new generation fully automatic thermal desorption instrument with 0 samples.

ATDS-30S type dual channel fully automatic thermal desorption instrumentCan be used with all imported and domestic gas chromatographs, cansatisfyThe following standards:

1.HJ/644-2013 Determination of volatile organic compounds in ambient air - Adsorption tube sampling - Thermal desorption gas chromatography-mass spectrometry method ";

2.HJ/T400-2007 Sampling and Determination Method for Volatile Organic Compounds and Aldehydes and Ketones in Vehicles ";

3.GB/T18883-2002 Indoor Air Quality Standards;

4.HJ/583-2010 Determination of Benzene Compounds in Environmental Air Solid Adsorption/Thermal Desorption Gas Chromatography;

5. GB/50325-202Indoor environmental pollution control in civil construction projectsstandard

6.HJ 734-2014 Determination of volatile organic compounds in fixed source exhaust gas Solid phase adsorption thermal desorption/gas chromatography-mass spectrometry method》Wait, wait.

2、 InstrumentCharacteristics and main functions

1. It can automatically run two channels, one each-30 samples, no need for personnel on duty;

2. Power on self-test, fault alarm and prompt, automatic positioning and calibration of sample disk;

3. Microcomputer program control, with main functions including:

⑴ Method parameter setting, real-time animation display of working status, and running time;

⑵ The desorption zone, injection valve, sample transfer tube, and secondary desorption zone are all separately heated and temperature controlled;

Can start synchronouslyGC、 The chromatographic data processing workstation can also be started with external programs;

4. The machine comes with the function of simulating and sampling standard samples, which makes it more convenient to create working curves through a thermal desorption instrument;

5. The built-in sampling tube activation program can be loaded to automatically activate the desorbed sampling tube;

6. Through time programming, automatic functions such as desorption, blow adsorption, re desorption, injection, and backwash cleaning can be achieved;

7. The sample transfer tube and injection valve have automatic blowback function, which avoids cross contamination of different samples;

8. In order to make it more convenient to use in conjunction with imported gas chromatographsaccurateIndeed, this instrument is also equipped with dedicated interfaces for various imported instruments, making it easy to connect;

9. For active substance analysis, an elastic quartz tube can be selected as the sample transfer tube;

10. The injection needle is easy to replace and can be connected to all models at home and abroadGC injection port.

3、 InstrumentMain technologiesparameter

1Desorption 1Temperature control range:

room temperature—400 In increments1Appointment;

2.Temperature control range of valve injection system:

room temperature220 Increase by 1Appointment;

3.Temperature control range of sample transfer pipeline:

room temperature240 In increments1Ren Shi

For operational safety, the temperature control of the transmission pipeline adopts low-voltage power supply

4. Desorption 2Temperature control range:

room temperature—400 In increments1Appointment;

(Heating rate)2000℃/min)

5.Temperature control range of cold trap:

-35℃—50℃In increments1Ren Shi

(Using electronic refrigeration device, no need for liquid nitrogen refrigeration)

6.Temperature control accuracy:< ±0.1℃

7Temperature control gradient:< ±0.1℃

8.Sample grade: Double30 digits

9Desorption recovery rate:>98%(Related to components);

10.Backblowing cleaningTraffic:0~600ml/Min (continuously adjustable);

11Simulated sampling flow rate: 100ml/min