ATDS-20A Fully Automatic Thermal Desorption Instrument
Product Introduction: The ATDS-20A fully automatic thermal desorption instrument is a new generation of fully automatic thermal desorption instrument
Product details

1-200H91H20B93.png

ATDS-20AType fully automatic thermal desorption instrument

1Instrument Introduction

ATDS-20AThe fully automatic thermal desorption instrument isBeijing Zhongyi Yusheng Technology Co., Ltd. has independently developed and launched a fully automated design, touch screen display, and more convenient operation that can run continuouslyA new generation fully automatic thermal desorption instrument with 20 samples.

ATDS-20A Fully Automatic Thermal Desorption InstrumentCan be used with all imported and domestic gas chromatographs, cansatisfyThe following standards:

1.HJ/644-2013 Determination of volatile organic compounds in ambient air - Adsorption tube sampling - Thermal desorption gas chromatography-mass spectrometry method ";

2.HJ/T400-2007 Sampling and Determination Method for Volatile Organic Compounds and Aldehydes and Ketones in Vehicles ";

3.GB T18883-2002 Indoor Air Quality Standard;

4.HJ/583-2010Determination of Benzene Compounds in Environmental AirSolid adsorption/Thermal desorption gas chromatography;

5. GB/50325-202Indoor environmental pollution control in civil construction projectsstandard

6.HJ 734-2014 Determination of volatile organic compounds in fixed source exhaust gas Solid phase adsorption thermal desorption/gas chromatography-mass spectrometry method》Wait, wait.

2、 InstrumentCharacteristics and main functions

1. It can automatically run 1-20 samples without the need for personnel on duty;

2. Power on self-test, fault alarm and prompt, automatic positioning and calibration of sample disk;

3. Microcomputer program control, with main functions including:

⑴ Method parameter setting, real-time animation display of working status, and running time;

⑵ The desorption zone, injection valve, sample transfer tube, and secondary desorption zone are all separately heated and temperature controlled;

⑶ Set up the analysis program and press the run button to automatically complete the analysis of all samples;

⑷ The GC and chromatographic data processing workstations can be started synchronously, and the device can also be started by external programs;

4. The machine comes with the function of simulating and sampling standard samples, which makes it more convenient to create working curves through a thermal desorption instrument;

5. Through time programming, automatic functions such as desorption, blow adsorption, re desorption, injection, and backwash cleaning can be achieved;

6. Adopting electronic refrigeration and second-order thermal desorption process to ensure narrow chromatographic peak shapes;

7. The sample transfer tube and injection valve have automatic blowback function, which avoids cross contamination of different samples;

In order to provide more convenient and accurate use for imported GC and GCMS, this instrument is also equipped with dedicated interfaces for various imported instruments,Can connect all models both domestically and internationallyGC、GCMS

9. For active substance analysis, an elastic quartz tube can be selected as the sample transfer tube;

3、 InstrumentMain technologiesparameter

1Desorption 1Temperature control range:

room temperature—400 In increments1Appointment;

2.Temperature control range of valve injection system:

room temperature220 Increase by 1Appointment;

3.Temperature control range of sample transfer pipeline:

room temperature240 In increments1Ren Shi

For operational safety, the temperature control of the transmission pipeline adopts low-voltage power supply

4. Desorption 2Temperature control range:

room temperature—400 In increments1Appointment;

(Heating rate)2000℃/min)

5.Temperature control range of cold trap:

-35℃—50℃In increments1Ren Shi

(Using electronic refrigeration device, no need for liquid nitrogen refrigeration)

6.Temperature control accuracy:< ±0.1

7Temperature control gradient:< ±0.1

8.Sample grade:20 people

9Desorption recovery rate:>98%(Related to components);

10.Backblowing cleaningTraffic:0~100ml/Min (continuously adjustable);

11. Simulated sampling flow rate: 100ml/min;

12.Instrument size:450×360×510mm3

13.Instrument weight: approximately30kg。